Panagiotis Kassanos

Dr. Panagiotis Kassanos

Hamlyn Centre, Institute of Global Health Innovation and the Department of Computing, Imperial College, London, UK
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SHSara Hooshmand
Sara Hooshmand
Panagiotis KassanosPanagiotis Kassanos
Panagiotis Kassanos
MKMeysam Keshavarz
Meysam Keshavarz
PDPelin Duru
Pelin Duru
CKCemre Irmak Kayalan
Cemre Irmak Kayalan
MBMustafa Kemal Bayazit
Mustafa Kemal Bayazit
With a rising emphasis on public safety and quality of life, there is an urgent need to ensure optimal air quality, both indoors and outdoors. Detecting toxic gaseous compounds plays a pivotal role in shaping our sustainable future. This review aims to elucidate the advancements in smart wearable (nano)sensors for monitoring harmful gaseous pollutants, such as ammonia (NH3), nitric oxide (NO), nitrous oxide (N2O), nitrogen dioxide (NO2), carbon monoxide (CO), carbon dioxide (CO2), hydrogen sulfide (H2S), sulfur dioxide (SO2), ozone (O3), hydrocarbons (CxHy), and hydrogen fluoride (HF). Differentiating this review from its predecessors, we shed light on the challenges faced in enhancing sensor performance and offer a deep dive into the evolution of sensing materials, wearable substrates, electrodes, and types of sensors. Noteworthy materials for robust detection systems encompass 2D nanostructures, carbon nanomaterials, conducting polymers, nanohybrids, and metal oxide semiconductors. A dedicated section dissects the significance of circuit integration, miniaturization, real-time sensing, repeatability, reusability, power efficiency, gas-sensitive material deposition, selectivity, sensitivity, stability, and response/recovery time, pinpointing gaps in the current knowledge and offering avenues for further research. To conclude, we provide insights and suggestions for the prospective trajectory of smart wearable nanosensors in addressing the extant challenges.

15 October 2021 in IEEE Sensors Journal
Verified
Journal Article
Open access
Panagiotis KassanosPanagiotis Kassanos
Panagiotis Kassanos
Electrical bioimpedance entails the measurement of the electrical properties of tissues as a function of frequency. It is thus a spectroscopic technique. It has been applied in a plethora of biomedical applications for diagnostic and monitoring purposes. In this tutorial, the basics of electrical bioimpedance sensor design will be discussed. The electrode/electrolyte interface is thoroughly described, as well as methods for its modelling with equivalent circuits and computational tools. The design optimization and modelling of bipolar and tetrapolar bioimpedance sensors is presented in detail, based on the sensitivity theorem. Analytical and numerical modelling approaches for electric field simulations based on conformal mapping, point electrode approximations and the finite element method (FEM) are also elaborated. Finally, current trends on bioimpedance sensors are discussed followed by an overview of instrumentation methods for bioimpedance measurements, covering aspects of voltage signal excitations, current sources, voltage measurement front-end topologies and methods for computing the electrical impedance.

6 March 2013 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Panagiotis KassanosPanagiotis Kassanos
Panagiotis Kassanos
ITIasonas F. Triantis
Iasonas F. Triantis
ADAndreas Demosthenous
Andreas Demosthenous
The measurement of electrical impedance is used in a plethora of biomedical applications. The most common technique used is synchronous demodulation, which provides the real and imaginary parts of the impedance. However, in practice, the method requires elaborate calibration and matching between the injection and monitoring stages. This paper presents the integrated realization of an alternative method that is less intricate to implement. The circuit was fabricated in a 0.35-μm CMOS technology, occupies an active area of 0.4 mm 2 , and dissipates about 21 mW of power from ±2.5 V supplies. The chip was used to measure equivalent RC circuits of the electrode-tissue interface over the frequency range of 100 Hz to 100 kHz, showing good correlation with the theoretical results.

23 September 2019 in Nanoscale Horizons
Verified
Journal Article
Closed access
PDF file
MKMeysam Keshavarz
Meysam Keshavarz
Panagiotis KassanosPanagiotis Kassanos
Panagiotis Kassanos
Bo TanBo Tan
Bo Tan
KVKrishnan Venkatakrishnan
Krishnan Venkatakrishnan
Schematic illustration shows remarkable SERS activities of self-doped Q-structured TiOx with oxygen vacancies compared to the Q-structured TiO2.

7 April 2014 in IEEE Sensors Journal
Verified
Journal Article
Open access
Panagiotis KassanosPanagiotis Kassanos
Panagiotis Kassanos
LCLoucas Constantinou
Loucas Constantinou
ITIasonas F. Triantis
Iasonas F. Triantis
ADAndreas Demosthenous
Andreas Demosthenous
Bioimpedance spectroscopy is used in a wide range of biomedical applications. This paper presents an integrated analog readout, which employs synchronous detection to perform galvanostatic multi-channel, multi-frequency bioimpedance measurements. The circuit was fabricated in a 0.35-μm CMOS technology and occupies an area of 1.52 mm 2 . The effect of random dc offsets is investigated, along with the use of chopping to minimize them. Impedance measurements of a known RC load and skin (using commercially available electrodes) demonstrate the operation of the system over a frequency range up to 1 MHz. The circuit operates from a ±2.5 V power supply and has a power consumption of 3.4-mW per channel.

1 April 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
SASalzitsa Anastasova-Ivanova
Salzitsa Anastasova-Ivanova
Panagiotis KassanosPanagiotis Kassanos
Panagiotis Kassanos
GYGuang-Zhong Yang
Guang-Zhong Yang
The measurement of Na+, K+ and H+ is essential in medicine and plays an important role in the assessment of tissue ischemia. Microfabrication, inkjet- and screen-printing can be used for solid contact ion selective electrodes (ISE) realization; these, however, can be non-standardized, costly and time consuming processes. We present the realization of ISEs on post-processed electrodes fabricated via standardized printed circuit board (PCB) manufacturing techniques. In vitro results are presented from two rigid platforms (32 ISEs) for liquid sample dip-stick measurements and two flexible platforms (6 and 32 ISEs) for post-surgical intestinal tissue monitoring, each with a common reference electrode (RE). These are combined with optimized tetrapolar bioimpedance sensors for tissue ischemia detection. Both electroless and hard gold PCB finishes are examined. Apart from the electroless rigid platform, the rest demonstrated comparable and superior performance, with the pH sensors demonstrating the greatest deviation; the flexible hard gold platform achieved a sensitivity 4.6mV/pH and 49.2mV/pH greater than the electroless flexible and rigid platforms, respectively. The best overall performance was achieved with the hard gold flexible platform with sensitivities as large as 73.4mV/pH, 56.3mV/log [Na+], and 57.4mV/log [K+] vs. custom REs on the same substrate. Simultaneous measurement of target analytes is demonstrated with test solutions and saliva samples. The results demonstrate superior performance to other PCB-based pH sensors and Na+ and K+ PCB-based sensors with comparable performance to potentiometric sensors fabricated with other techniques, paving the way towards mass-produced, low-cost, disposable, multi-parametric chemical sensing diagnostic platforms.