Ileana Mariana Mateș

Dr. Ileana Mariana Mateș


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2025 in Molecules
Verified
Journal Article
Open access
PDF file
Ecaterina MateiEcaterina Matei
Ecaterina Matei
Maria RâpăMaria Râpă
Maria Râpă
IMIleana Mariana Mateș
Ileana Mariana Mateș
APAnca Florentina Florentina Popescu
Anca Florentina Florentina Popescu
ABAlexandra Badiceanu
Alexandra Badiceanu
Cristina CovaliuCristina Covaliu
Cristina Covaliu
Heavy metals represent a class of pollutants detected at concentrations lower than 10 ppm in different matrices that are intensively monitored due to having a major impact on human health. Industrial activities including mining, agriculture, and transport, determine their presence in different environments. Corrosion phenomena of various installations, volcanic eruptions, or atmospheric deposition on the soil surface and in water can contaminate the respective environments. Atmospheric pollutants in the form of suspended dust particles with diameters below 10 microns are predominantly composed of different metallic species from Cd, Cr, Cu, Ni, etc. This paper presents a review of the main sources and types of heavy metals present in the atmosphere in the composition of particulate matter (PM), highlighting the main mechanisms of occurrence and detection techniques, including the impact on bio-geo-chemical processes in the soil and food chain, in close correlation with their impact on environment and human health. The purpose of this review is to highlight the current level of knowledge regarding the global situation of heavy metals in PM and to identify gaps as targets for future research.

29 April 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MUMihaela-Elena ULMEANU
Mihaela-Elena ULMEANU
IMIleana Mariana Mateș
Ileana Mariana Mateș
CDCristian DOICIN
Cristian DOICIN
MMMarian Mitrica
Marian Mitrica
VCVasile Alin Chirteș
Vasile Alin Chirteș
ASAugustin Semenescu
Augustin Semenescu
Traumatic brain injury is a leading cause of death and disability worldwide, with nearly 90% of the deaths coming from low- and middle-income countries. Severe cases of brain injury often require a craniectomy, succeeded by cranioplasty surgery to restore the integrity of the skull for both cerebral protection and cosmetic purposes. The current paper proposes a study on developing and implementing an integrative surgery management system for cranial reconstructions using bespoke implants as an accessible and cost-effective solution. Bespoke cranial implants were designed for three patients and subsequent cranioplasties were performed. Overall dimensional accuracy was evaluated on all three axes and surface roughness was measured with a minimum value of 2.209 μm for Ra on the convex and concave surfaces of the 3D-printed prototype implants. Improvements in patient compliance and quality of life were reported in postoperative evaluations of all patients involved in the study. No complications were registered from both short-term and long-term monitoring. Material and processing costs were lower compared to a metal 3D-printed implants through the usage of readily available tools and materials, such as standardized and regulated bone cement materials, for the manufacturing of the final bespoke cranial implants. Intraoperative times were reduced through the pre-planning management stages, leading to a better implant fit and overall patient satisfaction.

27 February 2025 in Metals
Verified
Journal Article
Open access
PDF file
MRMiguel López Ríos
Miguel López Ríos
Julia C. Mirza-RoscaJulia C. Mirza-Rosca
Julia C. Mirza-Rosca
IMIleana Mariana Mateș
Ileana Mariana Mateș
VGVictor Geantă
Victor Geantă
Ionelia VoiculescuIonelia Voiculescu
Ionelia Voiculescu
High-entropy alloys are novel metallic materials distinguished by very special mechanical and chemical properties that are superior to classical alloys, attracting high global interest for the study and development thereof for different applications. This work presents the creation and characterisation of an FeMoTaTiZr high-entropy alloy composed of chemical constituents with relatively low biotoxicity for human use, suitable for medical tools such as surgical scissors, blades, or other cutting tools. The alloy microstructure is dendritic in an as-cast state. The chemical composition of the FeMoTaTiZr alloy micro-zone revealed that the dendrites especially contain Mo and Ta, while the inter-dendritic matrix contains a mixture of Ti, Fe, and Zr. The structural characterisation of the alloy, carried out via X-ray diffraction, shows that the main phases formed in the FeMoTaTiZr matrix are fcc (Ti7Zr3)0.2 and hcp Ti2Fe after annealing at 900 °C for 2 h, followed by water quenching. After a second heat treatment performed at 900 °C for 15 h in an argon atmosphere followed by argon flow quenching, the homogeneity of the alloy was improved, and a new compound like Fe3.2Mo2.1, Mo0.93Zr0.07, and Zr(MoO4)2 appeared. The microhardness increased over 6% after this heat treatment, from 694 to 800 HV0.5, but after the second annealing and quenching, the hardness decreased to 730 HV0.5. Additionally, a Lactate Dehydrogenase (LDH) cytotoxicity assay was performed. Mesenchymal stem cells proliferated on the new FeMoTaTiZr alloy to a confluence of 80–90% within 10 days of analysis in wells where the cells were cultured on and in the presence of the alloy. When using normal human fibroblasts (NHF), both in wells with cells cultured on metal alloys and in those without alloys, an increase in LDH activity was observed. Therefore, it can be considered that certain cytolysis phenomena (cytotoxicity) occurred because of the more intense proliferation of this cell line due to the overcrowding of the culture surface with cells.

20 May 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
ADAlin Demetrian
Alin Demetrian
MCMihnea Cosmin Costoiu
Mihnea Cosmin Costoiu
ASAugustin Semenescu
Augustin Semenescu
Gigel ParaschivGigel Paraschiv
Gigel Paraschiv
OCOANA ROXANA CHIVU
OANA ROXANA CHIVU
IMIleana Mariana Mateș
Ileana Mariana Mateș
A clean environment is essential for human health and well-being. A significant share of total waste is represented by hospital waste that is produced in increasing quantities by sanitary units, with the appearance of the disposable tools. Taking into account the unfavourable environmental impact, the biological danger that this waste represents, and the restrictive legislation imposed by the European Union, urgent measures are needed to reduce their quantities. In this regard, the paper refers to the design of a completely reusable thoracic drainage system and to the positive implications that this system has on the amount of hospital waste. The research starts with the presentation of the medical system from Romania, continues with the classification of the hospital waste, then highlights the dangers and the risks caused by this and analyzes the impact on the sensitive groups. Furthermore, the paper presents the disposable bicameral and tricameral thoracic drainage device systems used in hospitals and then the advantages of using a completely reusable thoracic drainage system. The paper introduces also a research method based on the “opinion questioning”. The method uses a questionnaire with 23 items, addressed to physicians, because, despite restrictive legislation related to hospital waste management, this is not always respected. Each participant of the study works in a different hospital so that the questioned sample is representative.

10 September 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
I(Ionela Luminita Canuta (Bucuroiu)
Ionela Luminita Canuta (Bucuroiu)
AIAdrian Ioana
Adrian Ioana
IMIleana Mariana Mateș
Ileana Mariana Mateș
ASAugustin Semenescu
Augustin Semenescu
MASSIMO POLLIFRONIMASSIMO POLLIFRONI
MASSIMO POLLIFRONI
This study evaluates the efficiency of biodegradable polyurethane foams as thermal insulation materials compared to conventional materials like expanded polystyrene (EPS). Key parameters analyzed include thermal conductivity, energy savings, CO2 emission reductions, and investment payback periods. Biodegradable polyurethane foams demonstrated a thermal conductivity of 0.022 W/(m·K), significantly lower than EPS's 0.035 W/(m·K), leading to higher energy savings. Calculations reveal an annual energy saving of 443,820 kWh for polyurethane foams, compared to 441,330 kWh for EPS. Financially, polyurethane foams save approximately €53,258.4 annually, while EPS saves €52,959.6. In terms of environmental impact, polyurethane foams reduce CO2 emissions by 88,764 kg annually, versus 88,266 kg for EPS. Despite the higher initial cost of polyurethane foams (€50/m² compared to €30/m² for EPS), the payback period is remarkably short at 0.094 years (1.13 months) compared to EPS's 0.057 years (0.68 months). These findings high-light biodegradable polyurethane foams as a superior option for thermal insulation, offering significant energy, financial, and environmental benefits.

20 April 2025 in Materials
Verified
Journal Article
Open access
PDF file
IMIleana Mariana Mateș
Ileana Mariana Mateș
VGVictor Geantă
Victor Geantă
MDManu Doina
Manu Doina
KHKELEMEN Hajnal
KELEMEN Hajnal
OEOnici Adrian Emanuel
Onici Adrian Emanuel
Ionelia VoiculescuIonelia Voiculescu
Ionelia Voiculescu
In this paper, a new TaMoNbTiZr multielement alloy has been designed, using chemical elements that exhibit extremely low bio-toxicity for the human body. The alloy was obtained by melting in vacuum arc remelting (VAR) equipment MRF ABJ 900 from high-purity chemical elements (99.5%) as mini-ingots having about 40 g weight each. The biocompatible alloys underwent changes in hardness after performing the annealing at 900 °C for 2 h, followed by cooling in water. The new alloy had an average hardness in the cast state of 545 HV0.5, and after heat treatment, it hardened to a value of 984 HV0.5, over 40% higher than that in the casting state, which ensures a longer working period. To use them as materials for medical instruments, their biocompatibility was highlighted through specific laboratory tests. For this, mesenchymal stem cells isolated from bone tissue and a human fibroblast cell line were cultured in vitro on the TaMoNbTiZr alloy’s surface. The biocompatibility of the alloy with the biological environment was evaluated by analyzing cell viability, adhesion, and proliferation, and in parallel, the cytolysis effects manifested by the increase in lactate dehydrogenase activity in the culture media were analyzed.