Alberto Piana

Dr. Alberto Piana

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2022 in European Urology
Verified
Journal Article
Closed access
APAlberto Piana
Alberto Piana
AGAndrea Gallioli
Andrea Gallioli
DADaniele Amparore
Daniele Amparore
PDPietro Diana
Pietro Diana
ATAngelo Territo
Angelo Territo
ABAlberto Breda
Alberto Breda

4 March 2024 in Cancers
Verified
Journal Article
Open access
PDF file
APAlberto Piana
Alberto Piana
DADaniele Amparore
Daniele Amparore
MSMichele Sica
Michele Sica
GVGabriele Volpi
Gabriele Volpi
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
Michele Di DioMichele Di Dio
Michele Di Dio
The aim of “Precision Surgery” is to reduce the impact of surgeries on patients’ global health. In this context, over the last years, the use of three-dimensional virtual models (3DVMs) of organs has allowed for intraoperative guidance, showing hidden anatomical targets, thus limiting healthy-tissue dissections and subsequent damage during an operation. In order to provide an automatic 3DVM overlapping in the surgical field, we developed and tested a new software, called “ikidney”, based on convolutional neural networks (CNNs). From January 2022 to April 2023, patients affected by organ-confined renal masses amenable to RAPN were enrolled. A bioengineer, a software developer, and a surgeon collaborated to create hyper-accurate 3D models for automatic 3D AR-guided RAPN, using CNNs. For each patient, demographic and clinical data were collected. A total of 13 patients were included in the present study. The average anchoring time was 11 (6–13) s. Unintended 3D-model automatic co-registration temporary failures happened in a static setting in one patient, while this happened in one patient in a dynamic setting. There was one failure; in this single case, an ultrasound drop-in probe was used to detect the neoplasm, and the surgery was performed under ultrasound guidance instead of AR guidance. No major intraoperative nor postoperative complications (i.e., Clavien Dindo > 2) were recorded. The employment of AI has unveiled several new scenarios in clinical practice, thanks to its ability to perform specific tasks autonomously. We employed CNNs for an automatic 3DVM overlapping during RAPN, thus improving the accuracy of the superimposition process.

28 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
PPPietro Piazzolla
Pietro Piazzolla
GMGiorgia Marullo
Giorgia Marullo
Chiara InnocenteChiara Innocente
Chiara Innocente
Federico SalernoFederico Salerno
Federico Salerno
FPFrancesco Porpiglia
Francesco Porpiglia
Background: Addressing intraoperative bleeding remains a significant challenge in the field of robotic surgery. This research endeavors to pioneer a groundbreaking solution utilizing convolutional neural networks (CNNs). The objective is to establish a system capable of forecasting instances of intraoperative bleeding during robot-assisted radical prostatectomy (RARP) and promptly notify the surgeon about bleeding risks. Methods: To achieve this, a multi-task learning (MTL) CNN was introduced, leveraging a modified version of the U-Net architecture. The aim was to categorize video input as either “absence of blood accumulation” (0) or “presence of blood accumulation” (1). To facilitate seamless interaction with the neural networks, the Bleeding Artificial Intelligence-based Detector (BLAIR) software was created using the Python Keras API and built upon the PyQT framework. A subsequent clinical assessment of BLAIR’s efficacy was performed, comparing its bleeding identification performance against that of a urologist. Various perioperative variables were also gathered. For optimal MTL-CNN training parameterization, a multi-task loss function was adopted to enhance the accuracy of event detection by taking advantage of surgical tools’ semantic segmentation. Additionally, the Multiple Correspondence Analysis (MCA) approach was employed to assess software performance. Results: The MTL-CNN demonstrated a remarkable event recognition accuracy of 90.63%. When evaluating BLAIR’s predictive ability and its capacity to pre-warn surgeons of potential bleeding incidents, the density plot highlighted a striking similarity between BLAIR and human assessments. In fact, BLAIR exhibited a faster response. Notably, the MCA analysis revealed no discernible distinction between the software and human performance in accurately identifying instances of bleeding. Conclusion: The BLAIR software proved its competence by achieving over 90% accuracy in predicting bleeding events during RARP. This accomplishment underscores the potential of AI to assist surgeons during interventions. This study exemplifies the positive impact AI applications can have on surgical procedures.

1 December 2021 in European Urology
Verified
Journal Article
Closed access
ATAngelo Territo
Angelo Territo
APAlberto Piana
Alberto Piana
MFMatteo Fontana
Matteo Fontana
PDPietro Diana
Pietro Diana
AGAndrea Gallioli
Andrea Gallioli
ABAlberto Breda
Alberto Breda

Verified
Journal Article
Open access
PDF file
ASAntoni Sánchez-Puy
Antoni Sánchez-Puy
ABAlejandra Bravo-Balado
Alejandra Bravo-Balado
PDPietro Diana
Pietro Diana
Michael BaboudjianMichael Baboudjian
Michael Baboudjian
APAlberto Piana
Alberto Piana
EEEsteban Emiliani
Esteban Emiliani
(1) Background: New pulse modulation (PM) technologies in Holmium:YAG lasers are available for urinary stone treatment, but little is known about them. We aim to systematically evaluate the published evidence in terms of their lithotripsy performance. (2) Methods: A systematic electronic search was performed (MEDLINE, Scopus, and Cochrane databases). We included all relevant publications, including randomized controlled trials, non-randomized comparative and non-comparative studies, and in-vitro studies investigating Holmium:YAG lithotripsy performance employing any new PM. (3) Results: Initial search yielded 203 studies; 24 studies were included after selection: 15 in-vitro, 9 in-vivo. 10 In-vitro compared Moses with regular PM, 1 compared Quanta’s, 1 Dornier MedTech’s, 2 Moses with super Thulium Fiber Laser, and 1 compared Moses with Quanta PMs. Six out of seven comparative studies found a statistically significant difference in favor of new-generation PM technologies in terms of operative time and five out of six in fragmentation time; two studies evaluated retropulsion, both in favor of new-generation PM. There were no statistically significant differences regarding stone-free rate, lasing and operative time, and complications between Moses and regular PM when data were meta-analyzed. (4) Conclusions: Moses PM seems to have better lithotripsy performance than regular modes in in-vitro studies, but there are still some doubts about its in-vivo results. Little is known about the other PMs. Although some results favor Quanta PMs, further studies are needed.

16 November 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MSMichele Sica
Michele Sica
PPPietro Piazzolla
Pietro Piazzolla
DADaniele Amparore
Daniele Amparore
PVPaolo Verri
Paolo Verri
SCSabrina De Cillis
Sabrina De Cillis
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
More than ever, precision surgery is making its way into modern surgery for functional organ preservation. This is possible mainly due to the increasing number of technologies available, including 3D models, virtual reality, augmented reality, and artificial intelligence. Intraoperative surgical navigation represents an interesting application of these technologies, allowing to understand in detail the surgical anatomy, planning a patient-tailored approach. Automatic superimposition comes into this context to optimally perform surgery as accurately as possible. Through a dedicated software (the first version) called iKidney, it is possible to superimpose the images using 3D models and live endoscopic images during partial nephrectomy, targeting the renal mass only. The patient is 31 years old with a 28 mm totally endophytic right-sided renal mass, with a PADUA score of 9. Thanks to the automatic superimposition and selective clamping, an enucleoresection of the renal mass alone was performed with no major postoperative complication (i.e., Clavien–Dindo < 2). iKidney-guided partial nephrectomy is safe, feasible, and yields excellent results in terms of organ preservation and functional outcomes. Further validation studies are needed to improve the prototype software, particularly to improve the rotational axes and avoid human help. Furthermore, it is important to reduce the costs associated with these technologies to increase its use in smaller hospitals.