Michele Di Dio

Dr. Michele Di Dio

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2023 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
Santosh KumarSantosh Kumar
Santosh Kumar
VBVijesh Bhagat
Vijesh Bhagat
PSPrakash Sahu
Prakash Sahu
MCMithliesh Kumar Chaube
Mithliesh Kumar Chaube
ABAjoy Kumar Behera
Ajoy Kumar Behera
SASaeed Alsamhi
Saeed Alsamhi

4 March 2024 in Cancers
Verified
Journal Article
Open access
PDF file
APAlberto Piana
Alberto Piana
DADaniele Amparore
Daniele Amparore
MSMichele Sica
Michele Sica
GVGabriele Volpi
Gabriele Volpi
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
Michele Di DioMichele Di Dio
Michele Di Dio
The aim of “Precision Surgery” is to reduce the impact of surgeries on patients’ global health. In this context, over the last years, the use of three-dimensional virtual models (3DVMs) of organs has allowed for intraoperative guidance, showing hidden anatomical targets, thus limiting healthy-tissue dissections and subsequent damage during an operation. In order to provide an automatic 3DVM overlapping in the surgical field, we developed and tested a new software, called “ikidney”, based on convolutional neural networks (CNNs). From January 2022 to April 2023, patients affected by organ-confined renal masses amenable to RAPN were enrolled. A bioengineer, a software developer, and a surgeon collaborated to create hyper-accurate 3D models for automatic 3D AR-guided RAPN, using CNNs. For each patient, demographic and clinical data were collected. A total of 13 patients were included in the present study. The average anchoring time was 11 (6–13) s. Unintended 3D-model automatic co-registration temporary failures happened in a static setting in one patient, while this happened in one patient in a dynamic setting. There was one failure; in this single case, an ultrasound drop-in probe was used to detect the neoplasm, and the surgery was performed under ultrasound guidance instead of AR guidance. No major intraoperative nor postoperative complications (i.e., Clavien Dindo > 2) were recorded. The employment of AI has unveiled several new scenarios in clinical practice, thanks to its ability to perform specific tasks autonomously. We employed CNNs for an automatic 3DVM overlapping during RAPN, thus improving the accuracy of the superimposition process.

28 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
PPPietro Piazzolla
Pietro Piazzolla
GMGiorgia Marullo
Giorgia Marullo
Chiara InnocenteChiara Innocente
Chiara Innocente
Federico SalernoFederico Salerno
Federico Salerno
FPFrancesco Porpiglia
Francesco Porpiglia
Background: Addressing intraoperative bleeding remains a significant challenge in the field of robotic surgery. This research endeavors to pioneer a groundbreaking solution utilizing convolutional neural networks (CNNs). The objective is to establish a system capable of forecasting instances of intraoperative bleeding during robot-assisted radical prostatectomy (RARP) and promptly notify the surgeon about bleeding risks. Methods: To achieve this, a multi-task learning (MTL) CNN was introduced, leveraging a modified version of the U-Net architecture. The aim was to categorize video input as either “absence of blood accumulation” (0) or “presence of blood accumulation” (1). To facilitate seamless interaction with the neural networks, the Bleeding Artificial Intelligence-based Detector (BLAIR) software was created using the Python Keras API and built upon the PyQT framework. A subsequent clinical assessment of BLAIR’s efficacy was performed, comparing its bleeding identification performance against that of a urologist. Various perioperative variables were also gathered. For optimal MTL-CNN training parameterization, a multi-task loss function was adopted to enhance the accuracy of event detection by taking advantage of surgical tools’ semantic segmentation. Additionally, the Multiple Correspondence Analysis (MCA) approach was employed to assess software performance. Results: The MTL-CNN demonstrated a remarkable event recognition accuracy of 90.63%. When evaluating BLAIR’s predictive ability and its capacity to pre-warn surgeons of potential bleeding incidents, the density plot highlighted a striking similarity between BLAIR and human assessments. In fact, BLAIR exhibited a faster response. Notably, the MCA analysis revealed no discernible distinction between the software and human performance in accurately identifying instances of bleeding. Conclusion: The BLAIR software proved its competence by achieving over 90% accuracy in predicting bleeding events during RARP. This accomplishment underscores the potential of AI to assist surgeons during interventions. This study exemplifies the positive impact AI applications can have on surgical procedures.

Verified
Journal Article
Open access
PDF file
SBSabrina Bossio
Sabrina Bossio
Anna PerriAnna Perri
Anna Perri
RGRaffaella Gallo
Raffaella Gallo
ABAnna De Bartolo
Anna De Bartolo
Vittoria RagoVittoria Rago
Vittoria Rago
Antonio AversaAntonio Aversa
Antonio Aversa
Alpha-lipoic acid (ALA) is a natural antioxidant dithiol compound, exerting antiproliferative and antimetastatic effects in various cancer cell lines. In our study, we demonstrated that ALA reduces the cell growth of prostate cancer cells LNCaP and DU-145. Western blot results revealed that in both cancer cells, ALA, by upregulating pmTOR expression, reduced the protein content of two autophagy initiation markers, Beclin-1 and MAPLC3. Concomitantly, MTT assays showed that chloroquine (CQ) exposure, a well-known autophagy inhibitor, reduced cells’ viability. This was more evident for treatment using the combination ALA + CQ, suggesting that ALA can reduce cells’ viability by inhibiting autophagy. In addition, in DU-145 cells we observed that ALA affected the oxidative/redox balance system by deregulating the KEAP1/Nrf2/p62 signaling pathway. ALA decreased ROS production, SOD1 and GSTP1 protein expression, and significantly reduced the cytosolic and nuclear content of the transcription factor Nrf2, concomitantly downregulating p62, suggesting that ALA disrupted p62-Nrf2 feedback loop. Conversely, in LNCaP cells, ALA exposure upregulated both SOD1 and p62 protein expression, but did not affect the KEAP1/Nrf2/p62 signaling pathway. In addition, wound-healing, Western blot, and immunofluorescence assays evidenced that ALA significantly reduced the motility of LNCaP and DU-145 cells and downregulated the protein expression of TGFβ1 and vimentin and the deposition of fibronectin. Finally, a soft agar assay revealed that ALA decreased the colony formation of both the prostate cancer cells by affecting the anchorage independent growth. Collectively, our in vitro evidence demonstrated that in prostate cancer cells, ALA reduces cell growth and counteracts both migration and invasion. Further studies are needed in order to achieve a better understanding of the underlined molecular mechanisms.

16 November 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MSMichele Sica
Michele Sica
PPPietro Piazzolla
Pietro Piazzolla
DADaniele Amparore
Daniele Amparore
PVPaolo Verri
Paolo Verri
SCSabrina De Cillis
Sabrina De Cillis
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
More than ever, precision surgery is making its way into modern surgery for functional organ preservation. This is possible mainly due to the increasing number of technologies available, including 3D models, virtual reality, augmented reality, and artificial intelligence. Intraoperative surgical navigation represents an interesting application of these technologies, allowing to understand in detail the surgical anatomy, planning a patient-tailored approach. Automatic superimposition comes into this context to optimally perform surgery as accurately as possible. Through a dedicated software (the first version) called iKidney, it is possible to superimpose the images using 3D models and live endoscopic images during partial nephrectomy, targeting the renal mass only. The patient is 31 years old with a 28 mm totally endophytic right-sided renal mass, with a PADUA score of 9. Thanks to the automatic superimposition and selective clamping, an enucleoresection of the renal mass alone was performed with no major postoperative complication (i.e., Clavien–Dindo < 2). iKidney-guided partial nephrectomy is safe, feasible, and yields excellent results in terms of organ preservation and functional outcomes. Further validation studies are needed to improve the prototype software, particularly to improve the rotational axes and avoid human help. Furthermore, it is important to reduce the costs associated with these technologies to increase its use in smaller hospitals.

10 July 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Michele Di DioMichele Di Dio
Michele Di Dio
SBSimona Barbuto
Simona Barbuto
CBClaudio Bisegna
Claudio Bisegna
ABAndrea Bellin
Andrea Bellin
MBMario Boccia
Mario Boccia
Enrico CheccucciEnrico Checcucci
Enrico Checcucci
Recently, 3D models (3DM) gained popularity in urology, especially in nephron-sparing interventions (NSI). Up to now, the application of artificial intelligence (AI) techniques alone does not allow us to obtain a 3DM adequate to plan a robot-assisted partial nephrectomy (RAPN). Integration of AI with computer vision algorithms seems promising as it allows to speed up the process. Herein, we present a 3DM realized with the integration of AI and a computer vision approach (CVA), displaying the utility of AI-based Hyper Accuracy Three-dimensional (HA3D®) models in preoperative planning and intraoperative decision-making process of challenging robotic NSI. A 54-year-old Caucasian female with no past medical history was referred to the urologist for incidental detection of the right renal mass. Preoperative contrast-enhanced abdominal CT confirmed a 35 × 25 mm lesion on the anterior surface of the upper pole (PADUA 7), with no signs of distant metastasis. CT images in DICOM format were processed to obtain a HA3D® model. RAPN was performed using Da Vinci Xi surgical system in a three-arm configuration. The enucleation strategy was achieved after selective clamping of the tumor-feeding artery. Overall operative time was 85 min (14 min of warm ischemia time). No intra-, peri- and post-operative complications were recorded. Histopathological examination revealed a ccRCC (stage pT1aNxMx). AI is breaking new ground in medical image analysis panorama, with enormous potential in organ/tissue classification and segmentation, thus obtaining 3DM automatically and repetitively. Realized with the integration of AI and CVA, the results of our 3DM were accurate as demonstrated during NSI, proving the potentialities of this approach for HA3D® models’ reconstruction.