Solar energy utilization in the industry has grown substantially, resulting in heightened recognition of renewable energy sources from power plants and intelligent grid systems. One of the most important challenges in the solar energy field is detecting anomalies in photovoltaic systems. This paper aims to address this by using various machine learning algorithms and regression models to identify internal and external abnormalities in PV components. The goal is to determine which models can most accurately distinguish between normal and abnormal behavior of PV systems. Three different approaches have been investigated for detecting anomalies in solar power plants in India. The first model is based on a physical model, the second on a support vector machine (SVM) regression model, and the third on an SVM classification model. Grey wolf optimizer was used for tuning the hyper model for all models. Our findings will clarify that the SVM classification model is the best model for anomaly identification in solar power plants by classifying inverter states into two categories (normal and fault).
This study presents the use of a vision-based fuzzy-PID lane-keeping control system for the simulation of a single-track bicycle model. The lane-keeping system (LKS) processes images to identify the lateral deviation of the vehicle from the desired reference track and generates a steering control command to correct the deviation. The LKS was compared to other lane-keeping control methods, such as Ziegler–Nichols proportional derivative (PD) and model predictive control (MPC), in terms of response time and settling time. The fuzzy-PID controller had the best performance, with fewer oscillations and a faster response time compared to the other methods. The PD controller was not as robust under various conditions due to changing parameters, while the MPC was not accurate enough due to similar reasons. However, the fuzzy-PID controller showed the best performance, with a maximum lateral deviation of 2 cm, a settling time of 12 s, and Kp and Kd values of 0.01 and 0.06, respectively. Overall, this work demonstrates the potential of using fuzzy-PID control for effective lane recognition and lane-keeping in vehicles.
11 December 2023 in Multimedia Tools and Applications
This paper presents a simple mathematical and Simulink model of a two-phase hybrid stepper motor, where ignoring the permeance space harmonics of the hybrid stepper motor is regarded as the main physical assumption in this article. Moreover, the dq transformation method is adopted as the main mathematical approach for the derivation of the proposed model, where simple voltages, currents, and torque equations are obtained and used to build the proposed Simulink and circuit model of the stepper motor. The validity and the effectiveness of the proposed model are examined by comparing its results with the results collected from the Simulink model in the library of Matlab. The obtained simulation results showed that the proposed model achieved a high simplicity and high accuracy when compared with conventional models.
In the proposed work, the MATLAB program was used to model and simulate the performance of the investigated two-stage adsorption chiller with and without heat recovery using an activated carbon/methanol pair. The simulated model results were then validated by the experimental results conducted by Millennium Industries. The model was based on 10th order differential equations; six of them were used to predict bed, evaporator and condenser temperatures while the other four equations were used to calculate the adsorption isotherm and adsorption kinetics. The detailed validation is stated in the next paragraphs; for example, it clearly notes that the simulation model results for the two-stage air cooled chiller are well compared with the experimental data in terms of cooling capacity (6.7 kW for the model compared with 6.14 kW from the experimental results at the same conditions). The Coefficient of Performance (COP) predicted by this simulation was 0.4, which is very close to that given by the Carnot cycle working at the same operating conditions. The model optimized the switching time, adsorption/desorption time and heat recovery time to maximize both cooling capacity and COP. The model optimized the adsorption/desorption cycle time (300 to 400 s), switching cycle time (50 s) and heat recovery cycle time (30 s). The temporal history of bed, evaporator and condenser temperatures is provided by this model for both heat recovery and without heat recovery chiller operation modes. The importance of this study is that it will be used as a basis for future series production.
To compensate for the lack of fossil fuel-based energy production systems, hybrid renewable energy systems (HRES) would be a useful solution. Investigating different design conditions and components would help industry professionals, engineers, and policymakers in producing and designing optimal systems. In this article, different tracker systems, including vertical, horizontal, and two-axis trackers in an off-grid HRES that includes photovoltaic (PV), wind turbine (WT), diesel generator (Gen), and battery (Bat) are considered. The goal is to find the optimum (OP) combination of an HRES in seven locations (Loc) in Saudi Arabia. The proposed load demand is 988.97 kWh/day, and the peak load is 212.34 kW. The results of the cost of energies (COEs) range between 0.108 to 0.143 USD/kWh. Secondly, the optimum size of the PV panels with different trackers is calculated. The HRES uses 100 kW PV in combination with other components. Additionally, the size of the PVs where 100% PV panels are used to reach the load demand in the selected locations is found. Finally, two sensitivity analyses (Sens) on the proposed PV and tracker costs and solar GHIs are conducted. The main goal of the article is to find the most cost-effective tracker system under different conditions while considering environmental aspects such as the CO2 social penalty. The results show an increase of 35% in power production from PV (compared to not using a tracker) when using a two-axis tracker system. However, it is not always cost-effective. The increase in power production when using vertical and horizontal trackers (HT) is also significant. The findings show that introducing a specific tracker for all locations depends on renewable resources such as wind speed and solar GHI, as well as economic inputs. Overall, for GHIs higher than 5.5 kWh/m2/day, the vertical tracker (VT) is cost-effective.