S. Motta

S. Motta

Auto-generated profile, based on publicly available information

S. Motta

Paul Scherrer Institute

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
SMS Motta
S Motta
JCJeppe Brage Christensen
Jeppe Brage Christensen
FFF Frei
F Frei
PPP Peier
P Peier
EYE G Yukihara
E G Yukihara
Objective. This work aims at investigating the response of various thermally stimulated luminescence detectors (TLDs) and optically stimulated luminescence detectors (OSLDs) for dosimetry of ultra-high dose rate electron beams. The study was driven by the challenges of dosimetry at ultra-high dose rates and the importance of dosimetry for FLASH radiotherapy and radiobiology experiments. Approach. Three types of TLDs (LiF:Mg,Ti; LiF:Mg,Cu,P; CaF 2 :Tm) and one type of OSLD (Al 2 O 3 :C) were irradiated in a 15 MeV electron beam with instantaneous dose rates in the (1–324) kGy s −1 range. Reference dosimetry was carried out with an integrating current transformer, which was calibrated in absorbed dose to water against a reference ionization chamber. Additionally, dose rate independent BeO OSLDs were employed as a reference. Beam non-uniformity was addressed using a matrix of TLDs/OSLDs. Main results. The investigated TLDs were shown to be dose rate independent within the experimental uncertainties, which take into account the uncertainty of the dosimetry protocol and the irradiation uncertainty. The relative deviation between the TLDs and the reference dose was lower than 4 % for all dose rates. A decreasing response with the dose rate was observed for Al 2 O 3 :C OSLDs, but still within 10 % from the reference dose. Significance. The precision of the investigated luminescence detectors make them suitable for dosimetry of ultra-high dose rate electron beams. Specifically, the dose rate independence of the TLDs can support the investigation of the beam uniformity as a function of the dose rate, which is one of the challenges of the employed beam. Al 2 O 3 :C OSLDs provided high precision measurements, but the decreasing response with the dose rate needs to be confirmed by additional experiments.

17 February 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
SMS Motta
S Motta
JCJeppe Brage Christensen
Jeppe Brage Christensen
MTM Togno
M Togno
RSR Schäfer
R Schäfer
SSS Safai
S Safai
EYE G Yukihara
E G Yukihara
Objective. This work aims at characterizing LiF:Mg,Ti thermoluminescence detectors (TLDs) for dosimetry of a 250 MeV proton beam delivered at ultra-high dose rates (UHDR). Possible dose rate effects in LiF:Mg,Ti, as well as its usability for dosimetry of narrow proton beams are investigated. Approach. LiF:Mg,Ti (TLD-100TM Microcubes, 1 mm × 1 mm × 1 mm) was packaged in matrices of 5 × 5 detectors. The center of each matrix was irradiated with single-spot low-LET (energy >244 MeV) proton beam in the (1–4500) Gy s−1 average dose rates range. A beam reconstruction procedure was applied to the detectors irradiated at the highest dose rate (Gaussian beam sigma <2 mm) to correct for volumetric averaging effects. Reference dosimetry was carried out with a diamond detector and radiochromic films. The delivered number of protons was measured by a Faraday cup, which was employed to normalize the detector responses. Main results. The lateral beam spread obtained from the beam reconstruction agreed with the one derived from the radiochromic film measurements. No dose rates effects were observed in LiF:Mg,Ti for the investigated dose rates within 3% (k = 1). On average, the dose response of the TLDs agreed with the reference detectors within their uncertainties. The largest deviation (−5%) was measured at 4500 Gy s−1. Significance. The dose rate independence of LiF:Mg,Ti TLDs makes them suitable for dosimetry of UHDR proton beams. Additionally, the combination of a matrix of TLDs and the beam reconstruction can be applied to determine the beam profile of narrow proton beams.

2 February 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
SMS Motta
S Motta
RBRiccardo Dal Bello
Riccardo Dal Bello
JCJeppe Brage Christensen
Jeppe Brage Christensen
LBLily Bossin
Lily Bossin
EYE G Yukihara
E G Yukihara
Objective. The aim of this work is to investigate the dose rate dependence of thermoluminescence and optically stimulated luminescence detectors (TLDs and OSLDs) in a wide uniform ultra-high dose rate electron beam and demonstrate the potential use of TLDs and OSLDs to correct the ion recombination in air-filled ionization chambers. This study avoids previously reported complications related to the field size and homogeneity. Approach. Two types of OSLDs (BeO and Al 2 O 3 :C) and three types of TLDs (LiF:Mg,Ti, LiF:Mg,Cu,P, CaF 2 :Tm) were irradiated simultaneously in a uniform 16 MeV electron beam generated by a clinically decommissioned C-Arm LINAC, modified to deliver doses per pulse between 8.3 × 10 −4 Gy and 1.255 Gy, corresponding to instantaneous dose rates between 2 × 10 2 Gy s −1 and 3 × 10 5 Gy s −1 . A prototype ultra-thin parallel plate ionization chamber was employed as reference detector. Main results. Reproducible results were achieved both at conventional (standard deviation of the data <2%) and at the highest dose per pulse (standard deviation of the data <4%). No trend in the dose rate response of the TLDs and OSLDs was observed in the investigated dose per pulse range. The Al 2 O 3 :C OSLD was found to be the most precise detector, with a standard deviation of the data <2% at all investigated dose rates and dose levels. Significance. The dose rate independence of the investigated TLDs and OSLDs make them good candidates for dosimetry at ultra-high dose rates, at least up to 3 × 10 5 Gy s −1 . A dose rate independent method to measure the dose per pulse is proposed, which can be applied to characterize ultra-high dose rate electron beams and correct for ion recombination in ionization chambers.

12 September 2023 in Radiation Measurements
Verified
Journal Article
Open access
SMS. Motta
S. Motta
JCJ.B. Christensen
J.B. Christensen
EYE.G. Yukihara
E.G. Yukihara

10 October 2024 in Radiation Measurements
Verified
Journal Article
Open access
SMS. Motta
S. Motta
EYE.G. Yukihara
E.G. Yukihara