Harmonic loads and unbalanced loading in a distribution transformer lead to higher losses, an increase in temperature which leads to premature failure, and a shorter lifetime. To prevent these difficulties, the rated power of a transformer supplying non-linear loads or unbalanced load is reduced; commonly known as derating. In this paper, an alternative to traditional loss based derating is proposed. It is shown that derating might actually not be required when contrasted with the traditional approach. A perspective is presented on how to make the kVA rating "adaptive" and utilise the same kVA rating with or without harmonics. Actual field data is presented to support this viewpoint.
1 November 2017 in International Journal of Electrical Power & Energy Systems
The paper presents a physics-based method to calculate in real time the distribution of temperature in the active part of liquid immersed power transformers (LIPT) in a transient thermal processes during grid operation. The method is based on the detailed dynamic thermal-hydraulic network model (THNM). Commonly, up to now, lumped models have been used, whereby the temperatures are calculated at a few points (top-oil and hot-spot), and the parameters are determined from basic or extended temperature-rise tests and/or field operation. Numerous simplifications are made in such models and the accuracy of calculation decreases when the transformer operates outside the range of tested values (cooling stage, loading). The dynamic THNM reaches the optimum of accuracy and simplicity, being feasible for on-line application. The paper presents fundamental equations of dynamic THNM, which are structurally different from static THNM equations. The paper offers the numerical solver for the case of a closed-loop thermosyphon. To apply the method for real transformer grid operation, there is a need to develop details as in static THNM, which has been used to calculate the distribution of the temperatures in LIPT thermal design. The paper proves the concept of dynamic THNM using the experimental results of a closed-loop thermosyphon small-scale model, previously published by authors from McGill University in 2017. The comparison of dynamic THNM with measurements on that model are presented in the paper.
The paper presents the results of experimental research on radiator batteries for cooling oil immersed power transformers. A special test set up was built, consisting of a tank and heaters, simulating the active part of the transformer, and a radiator bank, with the pump in the pipe connecting the tank and the radiators. Fans were mounted below (vertical blowing) and on the side (horizontal blowing). The main parameters measured include: temperatures, oil flow and pressures in characteristic positions. The motivation behind the experimental research lies in the somewhat higher discrepancy between oil flows through the radiators calculated using detailed thermal-hydraulic model from the results of heat run tests in the case of forced oil flow and the application of the radiators for the outer cooling. Since the calculated oil flows were higher than the values obtained from the heat run test it was obvious that there are some additional pressure drops along the oil path. The hypothesis is that these pressure drops appear in the top and bottom head of the radiators. Corresponding measurements, analysis and steps taken to fine tune the detailed thermal-hydraulic model are presented in the paper.