Pedro Júdice

Dr. Pedro Júdice

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2021 in British Journal of Sports Medicine
Verified
Journal Article
Open access
PDF file
JMJan M Mühlen
Jan M Mühlen
JSJulie Stang
Julie Stang
ESEsben Lykke Skovgaard
Esben Lykke Skovgaard
PJPedro Júdice
Pedro Júdice
PMPablo Molina-Garcia
Pablo Molina-Garcia
MSMoritz Schumann
Moritz Schumann
Assessing vital signs such as heart rate (HR) by wearable devices in a lifestyle-related environment provides widespread opportunities for public health related research and applications. Commonly, consumer wearable devices assessing HR are based on photoplethysmography (PPG), where HR is determined by absorption and reflection of emitted light by the blood. However, methodological differences and shortcomings in the validation process hamper the comparability of the validity of various wearable devices assessing HR. Towards Intelligent Health and Well-Being: Network of Physical Activity Assessment (INTERLIVE) is a joint European initiative of six universities and one industrial partner. The consortium was founded in 2019 and strives towards developing best-practice recommendations for evaluating the validity of consumer wearables and smartphones. This expert statement presents a best-practice validation protocol for consumer wearables assessing HR by PPG. The recommendations were developed through the following multi-stage process: (1) a systematic literature review based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses, (2) an unstructured review of the wider literature pertaining to factors that may introduce bias during the validation of these devices and (3) evidence-informed expert opinions of the INTERLIVE Network. A total of 44 articles were deemed eligible and retrieved through our systematic literature review. Based on these studies, a wider literature review and our evidence-informed expert opinions, we propose a validation framework with standardised recommendations using six domains: considerations for the target population, criterion measure, index measure, testing conditions, data processing and the statistical analysis. As such, this paper presents recommendations to standardise the validity testing and reporting of PPG-based HR wearables used by consumers. Moreover, checklists are provided to guide the validation protocol development and reporting. This will ensure that manufacturers, consumers, healthcare providers and researchers use wearables safely and to its full potential.

4 March 2017 in International Journal of Behavioral Nutrition and Physical Activity
Verified
Journal Article
Open access
PDF file
PJPedro Júdice
Pedro Júdice
ASAnaliza M. Silva
Analiza M. Silva
JBJuliane Berria
Juliane Berria
EPEdio Luiz Petroski
Edio Luiz Petroski
UEUlf Ekelund
Ulf Ekelund
LSLuis Sardinha
Luis Sardinha
Strong evidence indicates that moderate-vigorous physical activity (MVPA) is positively associated with fitness in youth, independent of total sedentary-time. Sedentary-time appears negatively associated with fitness only when it replaces MVPA. However, whether different sedentary-patterns affect health-related fitness is unknown. The associations between MVPA and sedentary-patterns with physical fitness were examined in 2698 youths (1262 boys) aged 13.4 ± 2.28 years. Sedentary-time (counts · minute−1 < 100) and PA were objectively measured by accelerometry. Each break (≥100 counts · min−1 < 2295) in sedentary-time and the frequency of daily bouts in non-prolonged (<30 min) and prolonged (≥30 min) sedentary-time were determined. The FITNESSGRAM® test battery was used to assess fitness. A standardized fitness composite-score (z-score) was calculated by summing the individual z-scores of the five tests adjusted to age and sex. Positive associations between MVPA and fitness were observed in both boys (β = 0.013, 95% CI: 0.005; 0.021) and girls (β = 0.014, 95% CI: 0.006; 0.022), independent of sedentary-patterns. Modest associations were found for the breaks in sedentary-time with fitness (β = 0.026, 95% CI: 0.009; 0.042), independent of total sedentary-time and MVPA in boys. In girls, non-prolonged sedentary bouts were positively associated with fitness (β = 0.014, 95% CI: 0.003; 0.024), independent of total sedentary-time and MVPA. These results reinforce that, independent of the time and patterns of sedentary behavior, MVPA is consistently associated with fitness in youth. Modest and inconsistent associations were found for sedentary behaviors. Breaking-up sedentary-time in boys and non-prolonged sedentary bouts in girls were positively associated with fitness, independent of total sedentary-time and MVPA. In order to enhance youth’s fitness, public health recommendations should primarily target MVPA, still, suggestion to reduce and break-up sedentary-time may also be considered.

24 December 2020 in British Journal of Sports Medicine
Verified
Journal Article
Open access
PDF file
WJWilliam Johnston
William Johnston
PJPedro Júdice
Pedro Júdice
PMPablo Molina-Garcia
Pablo Molina-Garcia
JMJan M Mühlen
Jan M Mühlen
ESEsben Lykke Skovgaard
Esben Lykke Skovgaard
LSLuis Sardinha
Luis Sardinha
Consumer wearable and smartphone devices provide an accessible means to objectively measure physical activity (PA) through step counts. With the increasing proliferation of this technology, consumers, practitioners and researchers are interested in leveraging these devices as a means to track and facilitate PA behavioural change. However, while the acceptance of these devices is increasing, the validity of many consumer devices have not been rigorously and transparently evaluated. The Towards Intelligent Health and Well-Being Network of Physical Activity Assessment (INTERLIVE) is a joint European initiative of six universities and one industrial partner. The consortium was founded in 2019 and strives to develop best-practice recommendations for evaluating the validity of consumer wearables and smartphones. This expert statement presents a best-practice consumer wearable and smartphone step counter validation protocol. A two-step process was used to aggregate data and form a scientific foundation for the development of an optimal and feasible validation protocol: (1) a systematic literature review and (2) additional searches of the wider literature pertaining to factors that may introduce bias during the validation of these devices. The systematic literature review process identified 2897 potential articles, with 85 articles deemed eligible for the final dataset. From the synthesised data, we identified a set of six key domains to be considered during design and reporting of validation studies: target population, criterion measure, index measure, validation conditions, data processing and statistical analysis. Based on these six domains, a set of key variables of interest were identified and a ‘basic’ and ‘advanced’ multistage protocol for the validation of consumer wearable and smartphone step counters was developed. The INTERLIVE consortium recommends that the proposed protocol is used when considering the validation of any consumer wearable or smartphone step counter. Checklists have been provided to guide validation protocol development and reporting. The network also provide guidance for future research activities, highlighting the imminent need for the development of feasible alternative ‘gold-standard’ criterion measures for free-living validation. Adherence to these validation and reporting standards will help ensure methodological and reporting consistency, facilitating comparison between consumer devices. Ultimately, this will ensure that as these devices are integrated into standard medical care, consumers, practitioners, industry and researchers can use this technology safely and to its full potential.

1 April 2016 in Clinical Nutrition
Verified
Journal Article
Closed access
CMCatarina N. Matias
Catarina N. Matias
DSDiana Santos
Diana Santos
PJPedro Júdice
Pedro Júdice
JMJoão P. Magalhães
João P. Magalhães
CMCláudia S. Minderico
Cláudia S. Minderico
ASAnaliza M. Silva
Analiza M. Silva

14 October 2015 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
PJPedro Júdice
Pedro Júdice
MHMarc T. Hamilton
Marc T. Hamilton
LSLuis Sardinha
Luis Sardinha
TZTheodore W. Zderic
Theodore W. Zderic
ASAnaliza M. Silva
Analiza M. Silva

17 December 2018 in International Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
Francesco CampaFrancesco Campa
Francesco Campa
GSGabriele Semprini
Gabriele Semprini
PJPedro Júdice
Pedro Júdice
GMGianluca Messina
Gianluca Messina
STStefania Toselli
Stefania Toselli
This study aimed to evaluate the associations of anthropometry, functional movement patterns (FMP) and physical performance characteristics with repeated-sprint ability (RSA) in male youth soccer players. Thirty six athletes (ages 16.6±0.5 years, BMI 22.0±1.3 kg/m2) completed the RSA test and other physical tests including countermovement jump with (CMJA) and without the help of arms (CMJ), 10-m and 20-m straight-line sprints, Yo-Yo Intermittent Recovery Test Level 1 (Yo-Yo), and functional movement screen (FMS). In addition, a battery of anthropometric variables was measured. RSA performance components such as best time (BT), mean time (MT) and sprint decrement were calculated. Results showed that measures of physical performance derived from horizontal plane in 10-m and 20-m sprints, were more strongly associated (p<0.01) with RSA performance than those obtained with CMJ or CMJA (p<0.05). High correlations (p<0.01) were found between MT, BT and Yo-Yo distance (r=−0.79, r=−0.67, respectively), as well as with FMS scores (r=−0.68, r=−0.58, respectively). Anthropometric measures, such as fat mass, upper fat area, thigh fat area, calf muscle area, and endomorphy were associated with RSA components (p<0.05). Predictors for the RSA performance identified in the stepwise multivariate analysis included Yo-Yo distance, time in sprints, FMP, and calf muscle area.