Arterial pulse waves (PWs) such as blood pressure and photoplethysmogram (PPG) signals contain a wealth of information on the cardiovascular (CV) system that can be exploited to assess vascular age and identify individuals at elevated CV risk. We review the possibilities, limitations, complementarity, and differences of reduced-order, biophysical models of arterial PW propagation, as well as theoretical and empirical methods for analyzing PW signals and extracting clinically relevant information for vascular age assessment. We provide detailed mathematical derivations of these models and theoretical methods, showing how they are related to each other. Finally, we outline directions for future research to realize the potential of modeling and analysis of PW signals for accurate assessment of vascular age in both the clinic and in daily life.
29 November 2019 in IEEE Journal of Biomedical and Health Informatics
Goal: We introduce a novel approach to estimate cardiac output (CO) and central systolic blood pressure (cSBP) from noninvasive measurements of peripheral cuff-pressure and pulse wave velocity (PWV). Methods: The adjustment of a previously validated one-dimensional arterial tree model is achieved via an optimization process. In the optimization loop, compliance and resistance of the generic arterial tree model as well as aortic flow are adjusted so that simulated brachial systolic and diastolic pressures and cf-PWV converge towards the measured brachial systolic and diastolic pressures and cf-PWV. The process is repeated until full convergence in terms of both brachial pressures and PWV is reached. To assess the accuracy of the proposed framework, we implemented the algorithm on in vivo anonymized data from 20 subjects and compared the method-derived estimates of CO and cSBP to patient-specific measurements obtained with Mobil-O-Graph apparatus (central pressure) and two-dimensional transthoracic echocardiography (aortic blood flow). Results: Both CO and cSBP estimates were found to be in good agreement with the reference values achieving an RMSE of 0.36 L/min and 2.46 mmHg, respectively. Low biases were reported, namely -0.04±0.36 L/min for CO predictions and -0.27±2.51 mmHg for cSBP predictions. Significance: Our one-dimensional model can be successfully “tuned” to partially patient-specific standards by using noninvasive, easily obtained peripheral measurement data. The in vivo evaluation demonstrated that this method can potentially be used to obtain central aortic hemodynamic parameters in a noninvasive and accurate way.
Cardiac and aortic characteristics are crucial for cardiovascular disease detection. However, noninvasive estimation of aortic hemodynamics and cardiac contractility is still challenging. This paper investigated the potential of estimating aortic systolic pressure (aSBP), cardiac output (CO), and end-systolic elastance (Ees) from cuff-pressure and pulse wave velocity (PWV) using regression analysis. The importance of incorporating ejection fraction (EF) as additional input for estimating Eeswas also assessed. The models, including Random Forest, Support Vector Regressor, Ridge, Gradient Boosting, were trained/validated using synthetic data (n = 4,018) from an in-silico model. When cuff-pressure and PWV were used as inputs, the normalized-RMSEs/correlations for aSBP, CO, and Ees(best-performing models) were 3.36 ± 0.74%/0.99, 7.60 ± 0.68%/0.96, and 16.96 ± 0.64%/0.37, respectively. Using EF as additional input for estimating Eessignificantly improved the predictions (7.00 ± 0.78%/0.92). Results showed that the use of noninvasive pressure measurements allows estimating aSBP and CO with acceptable accuracy. In contrast, Eescannot be predicted from pressure signals alone. Addition of the EF information greatly improves the estimated Ees. Accuracy of the model-derived aSBP compared to in-vivo aSBP (n = 783) was very satisfactory (5.26 ± 2.30%/0.97). Future in-vivo evaluation of CO and Eesestimations remains to be conducted. This novel methodology has potential to improve the noninvasive monitoring of aortic hemodynamics and cardiac contractility.
13 May 2021 in Frontiers in Bioengineering and Biotechnology
In-vivo assessment of aortic characteristic impedance (Zao) and total arterial compliance (CT) has been hampered by the need for either invasive or inconvenient and expensive methods to access simultaneous recordings of aortic pressure and flow, wall thickness, and cross-sectional area. In contrast, regional pulse wave velocity (PWV) measurements are non-invasive and clinically available. In this study, we present a non-invasive method for estimating Zao and CT using cuff pressure, carotid-femoral PWV (cfPWV), and carotid-radial PWV (crPWV). Regression analysis is employed for both Zao and CT. The regressors are trained and tested using a pool of virtual subjects (n = 3,818) generated from a previously validated in-silico model. Predictions achieved an accuracy of 7.40%, r = 0.90, and 6.26%, r = 0.95, for Zao, and CT, respectively. The proposed approach constitutes a step forward to non-invasive screening of elastic vascular properties in humans by exploiting easily obtained measurements. This study could introduce a valuable tool for assessing arterial stiffness reducing the cost and the complexity of the required measuring techniques. Further clinical studies are required to validate the method in-vivo.
Background: Arrhythmia symptoms are frequent complaints in children and often require a pediatric cardiology evaluation. Data regarding the clinical utility of wearable technologies are limited in children. We hypothesize that an Apple Watch can capture arrhythmias in children. Methods: We present an analysis of patients ≤18 years-of-age who had signs of an arrhythmia documented by an Apple Watch. We include patients evaluated at our center over a 4-year-period and highlight those receiving a formal arrhythmia diagnosis. We evaluate the role of the Apple Watch in arrhythmia diagnosis, the results of other ambulatory cardiac monitoring studies, and findings of any EP studies. Results: We identify 145 electronic-medical-record identifications of Apple Watch, and find arrhythmias confirmed in 41 patients (28%) [mean age 13.8 ± 3.2 years]. The arrythmias include: 36 SVT (88%), 3 VT (7%), 1 heart block (2.5%) and wide 1 complex tachycardia (2.5%). We show that invasive EP study confirmed diagnosis in 34 of the 36 patients (94%) with SVT (2 non-inducible). We find that the Apple Watch helped prompt a workup resulting in a new arrhythmia diagnosis for 29 patients (71%). We note traditional ambulatory cardiac monitors were worn by 35 patients (85%), which did not detect arrhythmias in 10 patients (29%). In 73 patients who used an Apple Watch for recreational or self-directed heart rate monitoring, 18 (25%) sought care due to device findings without any arrhythmias identified. Conclusion: We demonstrate that the Apple Watch can record arrhythmia events in children, including events not identified on traditionally used ambulatory monitors.
18 October 2021 in European Heart Journal - Digital Health
Vascular ageing biomarkers have been found to be predictive of cardiovascular risk independently of classical risk factors, yet are not widely used in clinical practice. In this review, we present two basic approaches for using machine learning (ML) to assess vascular age: parameter estimation and risk classification. We then summarize their role in developing new techniques to assess vascular ageing quickly and accurately. We discuss the methods used to validate ML-based markers, the evidence for their clinical utility, and key directions for future research. The review is complemented by case studies of the use of ML in vascular age assessment which can be replicated using freely available data and code.