In this paper, to improve the speed control performance of PMSM direct drive servo systems under low-speed operation, a composite control strategy based on rotor position tracking (RPTC) and deadbeat predictive current (DPCC) is proposed, and a dual-loop control framework is established for the position loop-current loop. RPTC converts the speed command into real-time rotor position trajectory to smoothly track the rotor position, which can effectively eliminate the speed calculation error, and the strategy shows good speed following performance and anti-disturbance capability in low-speed conditions; The DPCC based on the “two-step prediction” is used to compensate for the effect of control delay, and the influence of inverter nonlinear factors is reduced by deadtime compensation, which effectively improves the dynamic performance of the current loop, and further enhances the speed control performance under low-speed. The efficacy of the proposed composite control strategies is validated through the presentation of extensive comparative simulations and experimental results.
1 February 2016 in IOP Conference Series: Materials Science and Engineering
The authors carried out a theoretical and experimental study of dual stator winding squirrel cage asynchronous generator (DSWA) behaviour in the presence of saturation regime (non-sinusoidal) due to the variable speed operation. The main aims are the determination of the relations of calculating the equivalent parameters of the machine windings, FEM validation of parameters and characteristics with free FEMM 4.2 computing software and the practice experimental tests for verifying them. Issue is limited to three phase range of double stator winding cage-asynchronous generator of small sized powers, the most currently used in the small adjustable speed wind or hydro power plants. The tests were carried out using three-phase asynchronous generator having rated power of 6 [kVA].
18 June 2015 in IOP Conference Series: Materials Science and Engineering
In the present paper is carried out a theoretical and experimental study of dual stator winding squirrel cage asynchronous generator (DSWA) behavior in the presence of saturation regime (non-sinusoidal) due to the variable speed operation. The main aims are the determination of the relations of calculating the equivalent parameters of the machine windings to optimal design using a Matlab code. Issue is limited to three phase range of double stator winding cage-induction generator of small sized powers, the most currently used in the small adjustable speed wind or hydro power plants. The tests were carried out using three-phase asynchronous generator having rated power of 6 [kVA].
13 December 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In this paper, a dynamic current control strategy based on reduced-order observer (ROO) is proposed for dual stator-winding induction generator (DWIG), in order to suppress the disturbances and to improve the current dynamic response. Because of two stator windings, the mathematical model of DWIG is more complex and has higher order and more coupling terms, which makes poor current dynamic performance. In the proposed control strategy, by establishing the mathematical relations between the control winding (CW) current, power winding (PW) currents and rotor flux, the total disturbances of CW current are determined, observed by ROO and introduced into the current-control loop for feedforward compensation. The influence of observer parameters and parameter mismatch on the stability, rapidity and disturbance-rejection ability is also analyzed, which guides the parameter tuning of the ROO. The simulation and experiments verify the validity of the proposed current controller. The dynamic performance of is improved and the dynamic regulation time of current is shortened by more than half compared to traditional proportional-integral current controller. Moreover, the proposed current control strategy also has good robustness under the variation of machine parameters.
12 January 2018 in IOP Conference Series: Materials Science and Engineering
The water feeding system of the urban and rural localities is mainly collected with feed pipes which can have different lengths and different levels. Before using, water must be treated. Since the treatment take place in the tanks, the pressure in the inlet of the station must be diminished. Many times the pressure must be reduced with 5-15 Barr and this is possible using valves, cavils, and so on. The flow capacity of the water consumption is highly fluctuating during one day, depending on the season, etc. This paper presents a method to use the hydroelectric potential of the feed pipes using a hydraulic turbine instead of the classical methods for decreasing the pressure. To avoid the dissipation of water and a good behavior of the power parameters it is used an asynchronous generator (AG) which is coupled at the electrical distribution network through a static frequency converter (SFC). The turbine has a simple structure without the classical devices (used to regulate the turbine blades). The speed of rotation is variable, depending on the necessary flow capacity in the outlet of the treatment station. The most important element of the automation is the static frequency converter (SFC) which allows speeds between 0 and 1.5 of the rated speed of rotation and the flow capacity varies accordingly with it.
In an effort to introduce a low cost (PM less), low power electric wind or hydro generators, this paper reports on preliminary design aspects, equivalent magnetic circuit and 3D FEM analysis of a 2.5 KVA, 250-1000 rpm, reactive homo-heteropolar brushless synchronous machine (RHHBSM).