Small-pitch 3D pixel sensors have been developed to equip the innermost layers of the ATLAS and CMS tracker upgrades at the High Luminosity LHC. They feature 50 × 50 and 25 × 100 m geometries and are fabricated on p-type Si–Si Direct Wafer Bonded substrates of 150 m active thickness with a single-sided process. Due to the short inter-electrode distance, charge trapping effects are strongly mitigated, making these sensors extremely radiation hard. Results from beam test measurements of 3D pixel modules irradiated at large fluences () indeed demonstrated high efficiency at maximum bias voltages of the order of 150 V. However, the downscaled sensor structure also lends itself to high electric fields as the bias voltage is increased, meaning that premature electrical breakdown due to impact ionization is a concern. In this study, TCAD simulations incorporating advanced surface and bulk damage models are used to investigate the leakage current and breakdown behavior of these sensors. Simulations are compared with measured characteristics of 3D diodes irradiated with neutrons at fluences up to 1.5 × 10. The dependence of the breakdown voltage on geometrical parameters (e.g., the n column radius and the gap between the n column tip and the highly doped p handle wafer) is also discussed for optimization purposes.
This paper addresses the complex behavior of Single-Electron Bipolar Avalanche Transistors (SEBATs) through a comprehensive modeling approach. TCAD simulations were used to analyze the behavior of the device during avalanche pulses triggered by electron injection. The simulations consider the avalanche process and charge flow and include the parasitic capacitances and resistances. A SPICE model is proposed using parameters extracted from the TCAD simulations. Both TCAD and SPICE simulations are validated against experimental results obtained on 150 nm CMOS devices and are employed to provide a clear understanding of the phenomena observed experimentally during SEBAT operation. The impact of parasitic elements on device operation is studied using simulations. This work enables the optimization of SEBAT devices and their integration in circuits for better signal-to-noise ratios, efficiency, and potential applications in sensing and digitizing low-level signals.
A design modification to an existing border termination for active‐edge planar radiation detectors is proposed, which enables a dead area reduction and a much larger breakdown voltage to be achieved, with a minor increase in the fabrication complexity. ‘Technology Computer‐Aided Design’ simulations allowed the device performance of different variants of the proposed structure to be investigated also in comparison with the existing one. Among considered designs, the new border terminations with 2(3) guard rings, featuring a dead area at the edge of ∼90(120) μm, can withstand more than 375(500) V for all oxide charge density values up to 3 × 10 12 cm −2 . These characteristics make them appealing for X‐ray imaging applications at free‐electron laser facilities.
A design modification to an existing 3D-trenched pixel detector is proposed, aimed at an improved fabrication yield. The device concept is studied and its performance is evaluated by TCAD simulations, in comparison to the existing one. Although the modified design features a less uniform electric field distribution, it is still expected to yield a very good timing performance and high radiation tolerance, also exploiting charge multiplication effects.
1 January 2021 in Journal of Physics: Conference Series
Applications at the High Luminosity LHC (HL-LHC) have required the development of a new generation of 3D pixel sensors with increased pixel granularity, extreme radiation hardness and low material budget. To this purpose, new 3D pixels have small pitch (e.g., 50×50 or 25×100 μm2) and reduced active thickness (∼100 μm). Owing to the small inter-electrode spacing (∼28 μm in the most aggressive designs). These 3D pixels are expected to be radiation hard even after irradiation at the hadron fluences. Indeed, they are of interest for the innermost tracking layers of ATLAS and CMS (∼2×1016 neq cm−2), and beyond. In order to estimate the charge collection efficiency (CCE) after irradiation, TCAD simulations can be conveniently used, providing useful information for the optimization of sensor design and fabrication technology. Within the AIDA-2020 project, with reference to the new single-sided 3D technology from FBK (Trento, Italy), we have simulated the CCE of pixel sensors with different inter-electrode spacing irradiated at different fluences. For these simulations, a 2D domain was used, consisting of a horizontal slice taken at half the depth of a 3D sensor. Simulations consider the hit of a minimum ionizing particle, described by the Heavy Ion model at different points within the active area. In addition, bulk radiation damage is accounted by using advanced deep-level trap models. This paper reports a comprehensive description of the simulation results based on a radiation model validated by comparison to experimental results from n-in-p strip detectors at 248 K and 900 V bias.