Yanhong Zhang

Prof. Dr. Yanhong Zhang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
GLGuoqing Liu
Guoqing Liu
YZYanhong Zhang
Yanhong Zhang
JRJunqing Ren
Junqing Ren
MXMing Xiao
Ming Xiao
In order to explore the influences of fault dislocations on tunnel stability under seismic action, a nonlinear dynamic simulation method for the rock–fault contact system is proposed. First, considering the deterioration effect of seismic action on the ultimate bearing load of the contact interface between rock mass and fault, a mathematical model is established reflecting the seismic deterioration laws of the contact interface. Then, based on the traditional point-to-point contact type in a geometric mesh, a point-to-surface contact type is also considered, and an improved dynamic contact force method is established, which considers the large sliding characteristics of the contact interface. According to the proposed method, a dynamic finite element calculation for the flow of the rock–fault contact system is designed, and the accuracy of the method is verified by taking a sliding elastic block as an example. Finally, a three-dimensional (3D) calculation model for a deep tunnel through a normal fault is built, and the nonlinear seismic damage characteristics of the tunnel under horizontal seismic action are studied. The results indicate that the relative dislocation between the rock mass and the fault is the main factor that results in lining damage and destruction. The seismic calculation results for the tunnel considering the dynamic interaction between the rock mass and the fault can more objectively reflect the seismic response characteristics of practical engineering. In addition, the influences of different fault thicknesses and dip angles on the seismic response of the tunnel are discussed. This work provides effective technical support for seismic fortification in a tunnel through fault.

13 May 2023 in Buildings
Verified
Journal Article
Open access
PDF file
JXJin Xiao
Jin Xiao
YZYanhong Zhang
Yanhong Zhang
YXYichuan Xing
Yichuan Xing
YJYangyang Jiao
Yangyang Jiao
LZLihong Zhang
Lihong Zhang
The composite post insulator composed of a large diameter mandrel and flange pressed by a one-time integral pultrusion has high strength and good toughness and is widely used in the existing flexible converter valve. For constructing the finite element model of the crimped post insulator, most of the flange surface and the mandrel surface are directly connected, making the simulation model’s stiffness deviate from the actual model and the model distortion. Based on this, this study proposes a new finite element simplified model of crimped composite post insulator based on multi-point constraints (MPC), which accurately simulates the crimping area of mandrel and flange in engineering practice. It verifies the model’s reliability through static tests and characteristic vibration tests. The results show that the difference between the finite element simulation and the test results is within 5%. The finite element modeling method based on MPC local constraints is very reliable in applying crimped composite post insulators. Based on the proposed model, the influence of flange height and thickness on the mechanical properties of composite post insulators is further explored. The results show that the influence of flange height on mechanical properties can be ignored when the height of the insulator stiffener (non-press common area) is constant. Within the allowable thickness range of the flange crimping process, the increase in flange thickness will significantly reduce the maximum bending stress of the insulator and increase its safety margin. It provides a good design idea for the design of crimping composite insulators.

21 April 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JXJin Xiao
Jin Xiao
YZYanhong Zhang
Yanhong Zhang
YXYichuan Xing
Yichuan Xing
YJYangyang Jiao
Yangyang Jiao
LZLihong Zhang
Lihong Zhang
The composite post insulator composed of a large diameter mandrel and flange pressed by one-time integral pultrusion has high strength and good toughness, widely used in the existing flexible converter valve. For constructing the finite element model of the crimped post insulator, most of the flange surface and the mandrel surface are directly connected, making the simulation model's stiffness deviate from the actual model and the model distortion. Based on this, this study proposes a new finite element simplified model of crimped composite post insulator based on Multi-Point Constraints (MPC), which accurately simulates the crimping area of man-drel and flange in engineering practice. It verifies the model's reliability through static tests and characteristic vibration tests. The results show that the difference between the finite element simulation and test results is within 5 %. The finite element modeling method based on MPC local constraints is very reliable in applying crimped composite post insulators. Based on the proposed model, the influence of flange height and thickness on the mechanical properties of composite post-insulators is further explored. The results show that the influence of flange height on mechanical properties can be ignored when the height of the insulator stiff-ener ( non-press common area ) is constant. Within the allowable thickness range of the flange crimping process, the increase in flange thickness will significantly reduce the maximum bend-ing stress of the insulator and increase its safety margin. It provides a good design idea for the design of crimping composite insulators.

7 February 2026 in Buildings
Verified
Journal Article
Open access
PDF file
ZFZeye Feng
Zeye Feng
YZYanhong Zhang
Yanhong Zhang
XHXiao Hu
Xiao Hu
HZHongdong Zhu
Hongdong Zhu
GXGuoliang Xing
Guoliang Xing
To address the challenge that traditional dam model materials are difficult to simultaneously meet the requirements of microstructural similarity, dynamic damage simulation, and environmental friendliness, a novel microparticle mortar simulated concrete was developed. This new material consists of cement, sand, gypsum, mineral oil, water, and baryte sand. Through systematic material mechanical tests, the effects of each component on the material’s strength, density, and elastic modulus were revealed, and the optimal mix ratio was determined. This enabled precise control of low elastic modulus and had a high density, while the material is environmentally friendly, non-toxic, and compatible with direct contact with natural water. Its mechanical properties are highly similar to those of the prototype concrete. Based on a 1:70 geometric scale, a shaking table model test of the concrete gravity dam-reservoir system was conducted. The dynamic response and damage evolution under empty and full reservoir conditions were compared and analyzed. The study shows that this material can accurately simulate the stress-strain relationship and failure mode of prototype concrete. Under the full reservoir condition, the dam’s fundamental frequency showed only a 2.72% deviation from the numerical simulation, and as the seismic excitation amplitude increased, the changes in the fundamental frequency effectively reflected the accumulation of damage. Under the design seismic motion, the measured accelerations and stress responses for both empty and full reservoir conditions were in good agreement with numerical calculations. Under overload conditions, the acceleration amplification factor at the dam crest decreased with damage accumulation, and the dam neck was identified as the seismic weak zone. As the peak ground acceleration (PGA) increased from 0.15 g to 0.70 g, the fundamental frequency changes effectively reflected the damage accumulation process in the dam, while the hydrodynamic pressure at the dam heel showed a linear increase (457% increase). The experimentally measured hydrodynamic pressure distribution was between the rigid dam and elastic dam hydrodynamic pressures, reflecting the real fluid-structure interaction effect. This study provides a reliable material solution and data support for dam seismic physical model testing.

25 May 2023 in Science and Technology of Nuclear Installations
Verified
Journal Article
Open access
PDF file
CYChen Yang
Chen Yang
YGYan Guo
Yan Guo
XHXiao Hu
Xiao Hu
YZYanhong Zhang
Yanhong Zhang
Establishing a dynamic model that accurately describes a realistic pressurized water reactor (PWR) fuel assembly is crucial to precisely evaluate the mechanical properties of the fuel assembly in seismic or loss of coolant accidents (LOCAs). The pluck test combined with the logarithmic decrement method has been widely applied in previous studies to extract fundamental modal parameters to calibrate dynamic models. However, most previous investigations focused on the first cycle of free vibration, which is strongly affected by stiction, baseline shift, drop conditions, and high-order mode interference, leading to inaccurate results. Moreover, these traditional methods cannot be used to extract high-order modal parameters. In this work, a novel experimental method for identifying the nonlinear modal parameters of a PWR fuel assembly is proposed. First, two algorithms are adopted to decompose the free vibration. Second, the local linearized modal parameters are extracted by a single-degree-of-freedom fitting method with a sliding window. Finally, these local linearized modal parameters are summed to obtain the nonlinear relationships between the modal parameters and amplitude. The new method makes more effective use of experimental data, obtains more accurate modal parameters than the logarithmic decrement method, and is capable of extracting high-order modal parameters. In the end, the test results are fitted by a fractional polynomial, which is of great value for numerical simulations.