Maura Milczewski

Dr. Maura Milczewski


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2012 in Sensors
Verified
Journal Article
Open access
PDF file
MMMaura Milczewski
Maura Milczewski
JSJean Carlos Cardozo Da Silva
Jean Carlos Cardozo Da Silva
CMCicero Martelli
Cicero Martelli
LGLeandro Grabarski
Leandro Grabarski
IAIlda Abe
Ilda Abe
HKHypolito José Kalinowski
Hypolito José Kalinowski
The aim of this work is to show the possibility of using fiber optic sensors to instrument inside parts of an artificial maxilla and measure internal tension transmitted by the orthodontic and orthopedic appliances to the dentition and the adjacent bone. Bragg gratings written in a standard optical fiber were used to monitor the maxillary teeth and a multiplexed fiber was used to monitor the surface of the maxillary bone, transversally to the longest axis of the teeth. A Universal Test Machine was used to evaluate the sensitivity of the sensor to the vertical and lateral forces applied on the teeth. A wavelength shift of approximately 0.30 nm was detected when applying loads ranging from 0 to 20 N. By applying forces using the standard orthodontic appliances installed on the dentition it was possible to detect a range of forces between 0.025 N to 0.035 N during the activation of the arch wire and extra-oral forces. The use of the internal sensors in an artificial model made possible the monitoring of the resulting forces on the internal parts of the teeth and at the position where the strain takes place within the maxilla. The sensors detected that the orthodontic forces were not transmitted to the surface of the maxilla. This information is important to elucidate and to correlate undesirable effects as tooth root absorption and local pain during the orthodontic treatment.

17 October 2012
Verified
Conference Paper
Closed access
LKLeandro Zen Karam
Leandro Zen Karam
MMMaura Milczewski
Maura Milczewski
HKHypolito José Kalinowski
Hypolito José Kalinowski
The objective of this study is to propose a new method to monitor the response of the periodontal ligament (PDL) to loading to understand its mechanical and physical properties. Fiber optic sensors are used to monitor internal strain (με) in the PDL in a pig mandible simulating longitudinal forces applied on the tooth. This consists therefore of an in vitro study. Results show that the sensor is sensitive to investigate external loading and unloading in the PDL. The results can help the study of PDL properties.