C.K. Yen

Dr. C.K. Yen


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CPCheng-Tang Pan
Cheng-Tang Pan
MFMark D. Francisco
Mark D. Francisco
CYC.K. Yen
C.K. Yen
SWShao-Yu Wang
Shao-Yu Wang
YSYow-Ling Shiue
Yow-Ling Shiue
One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventing possible pre-analytical error in the specimen collection and even more discomfort and pain to the patient. This paper is a review of the scientific publications on the different developed low-cost vein finder prototypes utilizing camera assisted near infrared (NIR) light technology. Methods: Electronic databases were searched online, these included PubMed (PMC), MEDLINE, Science Direct, ResearchGate, and Institute of Electrical and Electronics Engineers (IEEE) Xplore digital library. Specifically, publications with the terms vein finder prototype, NIR technology, vein detection, and infrared imaging were screened. In addition, reference lists were used to further review related publications. Results: Cannulation challenges medical practitioners because of the different factors that can be reduced by the utilization of a vein finder. A limited number of publications regarding the assessment of personnel performing cannulation were observed. Moreover, variations in methodology, number of patients, type of patients according to their demographics and materials used in the assessment of the developed prototypes were noted. Some studies were limited with regard to the actual human testing of the prototype. Conclusions: The development of a low-cost effective near infrared (NIR) vein finder remains in the phase of improvement. Since, it is being challenged by different human factors, increasing the number of parameters and participants/human for actual testing of the prototypes must also be taken into consideration for possible commercialization. Finally, it was noted that publications regarding the assessment of the performance of phlebotomists using vein finders were limited.

28 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZHZheng-Yu Hoe
Zheng-Yu Hoe
CCChun-Chieh Chang
Chun-Chieh Chang
JCJia-Jin Chen
Jia-Jin Chen
CYC.K. Yen
C.K. Yen
SWShao-Yu Wang
Shao-Yu Wang
CPCheng-Tang Pan
Cheng-Tang Pan
This research aimed to develop a direct-write near-field electrospinning system (DW-NFES) with three-axis positioning of controllable speed, torque and position to produce sizable and high-quality piezoelectric fibers for sensing purposes. Sensor devices with high electrical response signals were developed and tested. To achieve DW-NFES purpose, a servo motor controller was designed to develop a high response rate, accurate positioning, and stable mobile device through the calculation of bandwidth and system time delay. With this retooled system of DW-NFES, controllable and uniform size fibers in terms of diameters, stretching force, and interspaces can be obtained. Sensor devices can be made selectively without a complicated lithography process. The characteristics of this DW-NFES platform were featured by high response rate, accurate positioning, and stable movement to make fibers with high piezoelectric property. In this study, polyvinylidene fluoride (PVDF) was used to explore and enhance their sensing quality through the platform. The parametric study of the process factors on piezoelectric sensing signals mainly included the concentration of electrospinning PVDF solution, high voltage electric field, and collection speed. Finally, the surface morphology and piezoelectric properties of the as-electrospun PVDF fibers were examined by scanning electron microscopy (SEM) and characterized by electrical response measurement techniques. The results showed that the fiber spinning speed of the DW-NFES system could be increased to ~125 from ~20 mm/s and the accuracy precision was improved to ~1 from ~50 μm, compared to conventional step motor system. The fiber diameter reached ~10 μm, and the electrospinning pitch reached to as small as ~10 μm. The piezoelectric output voltage of the electrospun fibers was increased ~28.6% from ~97.2 to ~125 mV; the current was increased ~27.6% from ~163 to ~208 nA, suggesting that the piezoelectric signals can be enhanced significantly by using this retooled system. Finally, an external control module (Arduino-MAGE) was introduced to control the PVDF piezoelectric fiber sensors integrated as a sensing array. The behavior of long-term sedentary patients can be successfully detected by this module system to prevent the patients from the bedsores.