Shao-Yu Wang

Mr. Shao-Yu Wang

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CPCheng-Tang Pan
Cheng-Tang Pan
MFMark D. Francisco
Mark D. Francisco
CYC.K. Yen
C.K. Yen
SWShao-Yu Wang
Shao-Yu Wang
YSYow-Ling Shiue
Yow-Ling Shiue
One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventing possible pre-analytical error in the specimen collection and even more discomfort and pain to the patient. This paper is a review of the scientific publications on the different developed low-cost vein finder prototypes utilizing camera assisted near infrared (NIR) light technology. Methods: Electronic databases were searched online, these included PubMed (PMC), MEDLINE, Science Direct, ResearchGate, and Institute of Electrical and Electronics Engineers (IEEE) Xplore digital library. Specifically, publications with the terms vein finder prototype, NIR technology, vein detection, and infrared imaging were screened. In addition, reference lists were used to further review related publications. Results: Cannulation challenges medical practitioners because of the different factors that can be reduced by the utilization of a vein finder. A limited number of publications regarding the assessment of personnel performing cannulation were observed. Moreover, variations in methodology, number of patients, type of patients according to their demographics and materials used in the assessment of the developed prototypes were noted. Some studies were limited with regard to the actual human testing of the prototype. Conclusions: The development of a low-cost effective near infrared (NIR) vein finder remains in the phase of improvement. Since, it is being challenged by different human factors, increasing the number of parameters and participants/human for actual testing of the prototypes must also be taken into consideration for possible commercialization. Finally, it was noted that publications regarding the assessment of the performance of phlebotomists using vein finders were limited.

16 April 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
DLDa-Huei Lee
Da-Huei Lee
Cheng-Hsin ChuangCheng-Hsin Chuang
Cheng-Hsin Chuang
MSMuhammad Omar Shaikh
Muhammad Omar Shaikh
YDYong-Syuan Dai
Yong-Syuan Dai
SWShao-Yu Wang
Shao-Yu Wang
CPCheng-Tang Pan
Cheng-Tang Pan
Piezoresistive tactile sensors made using nanocomposite polymeric materials have been shown to possess good flexibility, electrical performance, and sensitivity. However, the sensing performance, especially in the low-pressure range, can be significantly improved by enabling uniform dispersion of the filler material and utilization of effective structural designs that improve the tactile sensing performance. In this study, a novel flexible piezoresistive tactile sensor with a grid-type microstructure was fabricated using polymer composites comprising multi-walled carbon nanotubes (MWCNTs) as the conductive filler and polydimethylsiloxane (PDMS) as the polymeric matrix. The research focused on improving the tactile sensor performance by enabling uniform dispersion of filler material and optimizing sensor design and structure. The doping weight ratio of MWCNTs in PDMS varied from 1 wt.% to 10 wt.% using the same grid structure-sensing layer (line width, line spacing, and thickness of 1 mm). The sensor with a 7 wt.% doping ratio had the most stable performance, with an observed sensitivity of 6.821 kPa−1 in the lower pressure range of 10–20 kPa and 0.029 kPa−1 in the saturation range of 30–200 kPa. Furthermore, the dimensions of the grid structure were optimized and the relationship between grid structure, sensitivity, and sensing range was correlated. The equation between pressure and resistance output was derived to validate the principle of piezoresistance. For the grid structure, dimensions with line width, line spacing, and thickness of 1, 1, and 0.5 mm were shown to have the most stable and improved response. The observed sensitivity was 0.2704 kPa−1 in the lower pressure range of 50–130 kPa and 0.0968 kPa−1 in the saturation range of 140–200 kPa. The piezoresistive response, which was mainly related to the quantum tunneling effect, can be optimized based on the dopant concentration and the grid microstructure. Furthermore, the tactile sensor showed a repeatable response, and the accuracy was not affected by temperature changes in the range of 10 to 40 °C and humidity variations from 50 to 80%. The maximum error fluctuation was about 5.6% with a response delay time of about 1.6 ms when cyclic loading tests were performed under a normal force of 1 N for 10,200 cycles. Consequently, the proposed tactile sensor shows practical feasibility for a wide range of wearable technologies and robotic applications such as touch detection and grasping.

23 December 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
Wen-Fan ChenWen-Fan Chen
Wen-Fan Chen
HOHsin‐You Ou
Hsin‐You Ou
KLKeng-Hao Liu
Keng-Hao Liu
ZLZhi-Yun Li
Zhi-Yun Li
CLChien-Chang Liao
Chien-Chang Liao
CPCheng-Tang Pan
Cheng-Tang Pan
Cancer is one of the common diseases. Quantitative biomarkers extracted from standard-of-care computed tomography (CT) scan can create a robust clinical decision tool for the diagnosis of hepatocellular carcinoma (HCC). According to the current clinical methods, the situation usually accounts for high expenditure of time and resources. To improve the current clinical diagnosis and therapeutic procedure, this paper proposes a deep learning-based approach, called Successive Encoder-Decoder (SED), to assist in the automatic interpretation of liver lesion/tumor segmentation through CT images. The SED framework consists of two different encoder-decoder networks connected in series. The first network aims to remove unwanted voxels and organs and to extract liver locations from CT images. The second network uses the results of the first network to further segment the lesions. For practical purpose, the predicted lesions on individual CTs were extracted and reconstructed on 3D images. The experiments conducted on 4300 CT images and LiTS dataset demonstrate that the liver segmentation and the tumor prediction achieved 0.92 and 0.75 in Dice score, respectively, by as-proposed SED method.

28 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZHZheng-Yu Hoe
Zheng-Yu Hoe
CCChun-Chieh Chang
Chun-Chieh Chang
JCJia-Jin Chen
Jia-Jin Chen
CYC.K. Yen
C.K. Yen
SWShao-Yu Wang
Shao-Yu Wang
CPCheng-Tang Pan
Cheng-Tang Pan
This research aimed to develop a direct-write near-field electrospinning system (DW-NFES) with three-axis positioning of controllable speed, torque and position to produce sizable and high-quality piezoelectric fibers for sensing purposes. Sensor devices with high electrical response signals were developed and tested. To achieve DW-NFES purpose, a servo motor controller was designed to develop a high response rate, accurate positioning, and stable mobile device through the calculation of bandwidth and system time delay. With this retooled system of DW-NFES, controllable and uniform size fibers in terms of diameters, stretching force, and interspaces can be obtained. Sensor devices can be made selectively without a complicated lithography process. The characteristics of this DW-NFES platform were featured by high response rate, accurate positioning, and stable movement to make fibers with high piezoelectric property. In this study, polyvinylidene fluoride (PVDF) was used to explore and enhance their sensing quality through the platform. The parametric study of the process factors on piezoelectric sensing signals mainly included the concentration of electrospinning PVDF solution, high voltage electric field, and collection speed. Finally, the surface morphology and piezoelectric properties of the as-electrospun PVDF fibers were examined by scanning electron microscopy (SEM) and characterized by electrical response measurement techniques. The results showed that the fiber spinning speed of the DW-NFES system could be increased to ~125 from ~20 mm/s and the accuracy precision was improved to ~1 from ~50 μm, compared to conventional step motor system. The fiber diameter reached ~10 μm, and the electrospinning pitch reached to as small as ~10 μm. The piezoelectric output voltage of the electrospun fibers was increased ~28.6% from ~97.2 to ~125 mV; the current was increased ~27.6% from ~163 to ~208 nA, suggesting that the piezoelectric signals can be enhanced significantly by using this retooled system. Finally, an external control module (Arduino-MAGE) was introduced to control the PVDF piezoelectric fiber sensors integrated as a sensing array. The behavior of long-term sedentary patients can be successfully detected by this module system to prevent the patients from the bedsores.

30 May 2019 in Polymers
Verified
Journal Article
Open access
PDF file
CPCheng-Tang Pan
Cheng-Tang Pan
SWShao-Yu Wang
Shao-Yu Wang
CYChung-Kun Yen
Chung-Kun Yen
CHChien-Kai Ho
Chien-Kai Ho
JYJhan-Foug Yen
Jhan-Foug Yen
YSYow-Ling Shiue
Yow-Ling Shiue
The electronic package interconnects electronic signals from one area to another and package delamination is a serious problem in the configuration of materials. This study focused on decreasing the delamination of the low-profile fine pitch ball grid array (LFBGA) and plastic ball grid array (PBGA) packages in terms of polymer thermal issue, metal bonding and bonding mechanisms. PBGA and LFBGA are a very common type of packaging processes in the electronics industry. The present study dealt first with delamination of the LFBGA packaging, through characterization and determination of physical and chemical properties such as surface roughness, surface energy, and contact angle. The relationship between surface roughness and delamination was verified through various roughness bonding experiments. In addition, the surface energy was determined by measuring the contact angle after cleaning the metal surface of Cu, Ni and Cr with Ar + O2 gas, and, this gas plasma treatment was applied to enhance the adhesive properties. The compositions of the surface were analyzed through an X-ray photoelectron spectroscopy (XPS). Also, the delamination issue between the corner of the heat sink cap and the epoxy resin was observed for delamination of the LFBGA packaging. Further, this study analyzed the PBGA packaging process through the finite element analysis simulation software ANSYS. To improve the heat sink cap delamination issue of the PBGA, a new chamfer design of the corner seat was streamlined to decrease the stress value and delamination. Besides, the simulation results demonstrated that the stress value reduced after increasing the shoulder length. The results implicate that the stress value is inversely proportional to the shoulder width and the chamfer radius. This study demonstrated that the optimization in design was able reduce the delamination phenomena in configuration material.

11 November 2023 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
YJYanli Jiang
Yanli Jiang
FFFengxian Fan
Fengxian Fan
PZPengfei Zhang
Pengfei Zhang
JWJun Wang
Jun Wang
WHWenjing Huang
Wenjing Huang
JZJing Zhang
Jing Zhang