SUMMARY INTRODUCTION Angiomyolipoma is one of the most common benign solid renal tumors. We investigated the characteristics of renal angiomyolipomas and the clinical outcomes of patients in the last thirteen years. METHODS The medical records of the patients who underwent nephrectomy were reviewed retrospectively from July 2005 to May 2018. The laboratory data, radiology, and pathology reports were recorded. Patients diagnosed with angiomyolipoma were included in the study. RESULTS A total of 28 patients were included in the study, eight of them male. The mean age of the patients was 55.89+14.49 years. The patients were treated with open and laparoscopic techniques. Partial nephrectomy was performed in 12 patients(42.85%). After pathological examination, 23 patients were diagnosed as fat rich, four patients as fat poor, and one as epithelioid angiomyolipoma. There were no recurrences in the follow-up 91.21+48.31 months. CONCLUSION Angiomyolipoma is a rare renal tumor in daily urology practice. Clinicians must be aware of its complications and manage patients well.
Induction heating (IH) technology is very popular in domestic applications because of its efficiency and safe operating properties. Resonant inverter circuits are widely used in IH systems owing to their high efficiency and soft-switching capability. Among the resonant inverters used in IH systems, the single-switch quasi-resonant inverter topology is generally preferred for low-cost and low-output-power applications. Despite the low-cost advantage of the quasi-resonant inverter, the soft-switching range is quite narrow, and it is not stable depending on the electrical parameters of the load that is desired to be heated. In other words, there is a critical relationship between the electrical characteristics of the pan, turn-on, and turn-off times, which are the control parameters of the semiconductor switch, and the safe working conditions. In addition, when the importance of closed-loop control methods is evaluated together with the selection of resonant circuit elements, it is essential to determine whether the load is suitable for heating, and to determine the electrical properties of the load to provide both reliable and efficient operating conditions. This study focuses on a new load-detection method based on circuit analysis for quasi-resonant induction hobs. After determining the load parameters, the turn-on and turn-off times of the semiconductor switch were determined to obtain the lowest possible switching loss. Therefore, the boundary conditions of the semiconductor switch are maintained within these limits. The proposed method and its advantages for the switch safe operating area were theoretically examined and proved through simulations and prototype circuits.
Objective: Renal cell carcinoma (RCC) is a tumor that has a tendency of vascular invasion by extending to the inferior vena cava (IVC) after the renal vein. The total resection of the renal tumor and tumor thrombus is considered the optimal treatment. In our study, we aimed to present the results related to 34 consecutive cases of RCC with tumor thrombus. Material and methods: Of the 442 patients diagnosed with renal tumors between January 2008 and January 2018, 34 (7.6%) had tumor thrombus over the renal vein extending to the IVC. The data of the 34 patients with tumor thrombus were retrospectively reviewed and included in the study. All the 34 patients underwent radical nephrectomy with tumor thrombectomy. The presence of thrombus was evaluated using contrast-enhanced abdominal tomography, magnetic resonance imaging, or color Doppler ultrasonography. The level of thrombus was classified using the Mayo Clinic tumor thrombus classification. Surgery was performed transperitoneally through a modified Chevron incision and mostly in collaboration with other clinics. Complications were classified according to the Clavien system. Results: Of the 34 patients, 22 were males and 12 were females. The mean follow-up period was 36±27.2 months in patients who had a mean age of 61±10.9 years. The mean tumor size was 10.5±3.3 cm. The number of patients according to the thrombus levels I, II, and III were 20, 9, and 5, respectively. The average blood loss was 744±285.4 mL. Radical surgery for all patients who had direct invasion to the vena cava wall and/or level II and III was performed by gastrointestinal and cardiothoracic surgeons. Cardiopulmonary bypass was not performed in any patient. Minor complications (Clavien grades 1-2) were seen in 8 (23.5%) patients, while 2 (5.8%) patients had major complications (Clavien grades 3–5). The mean follow-up period was 36 months (range, 6–72 months). The overall 5-year survival rate was 85.2%. Conclusion: We think that radical nephrectomy and caval thrombectomy is a safe and effective method in patients with RCC without tumor exceeding the diaphragmatic level. We believe that the surgical success rate can be increased using a multidisciplinary approach in selected cases. Cite this article as: Topaktaş R, Ürkmez A, Tokuç E, Kayar R, Kanberoğlu H, Öztürk Mİ. Surgical management of renal cell carcinoma with associated tumor thrombus extending into the inferior vena cava: A 10-year single-center experience. Turk J Urol 2019; 45(5): 345-50.
Induction heating is a commonly used method of heating in household appliances due to its efficiency and high reliability reasons. In induction cookers, resonant inverter circuits are frequently chosen due to their high efficiency and the ability to facilitate soft switching. Among the resonant inverters used in induction cookers, half-bridge series resonant (HBSR) inverter topology is often preferred for applications where a balance between cost and power is required. Despite the numerous circuit designs proposed to enhance the performance of HBSR converters, a standardized design methodology suitable for circuit design dedicated to induction cookers has not yet been established. In this study, a new HBSR inverter design methodology supported by various theoretical equations is proposed for use in household induction cooktops. In the proposed design, the first step involves calculating the equivalent resistance value of the coil. Subsequently, a coil capable of achieving to match this resistance value is designed mechanically. Finally, the capacitance value for the resonance circuit is calculated. Calculating the equivalent resistance value before designing the coil, in particular, enables the practical implementation of a viable coil design. To validate the proposed design methodology, it is necessary to control the power transferred to the resonant circuit. For this purpose, closed-loop power control is achieved using the peak value of coil current through frequency modulation technique. Additionally, it needs to be also proved that the implementation circuit works with soft switching between maximum and minimum switch cut-off current. To assess the compliance of the proposed design method with standards, thermal measurements were taken from semiconductors, EMC measurements were conducted to verify compliance with the IEC 55014-1 standard, and finally, the power transferred to the resonant circuit was calculated using oscilloscope measurements. Using the proposed design method, calculations were performed for a 20cm diameter iron pot with a 2300VA power transfer at 230VAC mains voltage. Subsequently, these calculations were verified using various simulation tools, and finally, a prototype implementation circuit was realized to demonstrate the reliability of the proposed design method.
Due to user safety, efficient heating, easy cleaning, fast heating, and smart design reasons, induction heating technology is very popular in home appliances. The technical developments for the induction technology can be seen in magnetic design, power electronic, and control techniques. These technical developments focus on developing induction heating futures without increase total system cost. In this study, it is aimed to analyze the existing converters which are using for induction cooking and compare them in terms of losses and efficiency. Conventional and AC-AC converters have been analyzed and compared for the single load and double loads conditions. Efficiency, semi-conductor quantity, total system cost, and control flexibility are main topics for comparison.