Semih Bal

Mr. Semih Bal

Budapest University of Technology and Economics
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2020 in Polymers
Verified
Journal Article
Open access
PDF file
GCGergely Csányi
Gergely Csányi
Semih BalSemih Bal
Semih Bal
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
The effect of short-term (3- and 6-h-long) periodic thermal aging was investigated at three different temperatures on PVC cables and PVC films. Three different temperatures (110, 125, and 140 °C) were used for aging PVC cables and one (110 °C) for PVC films. PVC films were prepared for the investigation containing 0, 30, 40, and 50 weight percent of dioctyl phthalate plasticizer (DOP). The effect of short-term thermal aging was monitored by electrical (dielectric spectrum and voltage response measurement) and mechanical (Shore D hardness) methods. From the loss factor measurements, different deducted quantities were calculated and compared with Shore D hardness, which has been shown to be a parameter reflecting the effect of short-term thermal aging on PVC insulation. The measurements revealed that Shore D hardness is not the best property for monitoring aging. Instead, increasing dissipated power and the shifting behavior of tan δ–frequency curves proved to be the best phenomena for assessing the impact of thermal aging. Simple deducted quantities may provide a basis for following short-term thermal aging.

1 June 2023 in Symmetry
Verified
Journal Article
Open access
PDF file
Semih BalSemih Bal
Semih Bal
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
The increasing penetration of distributed generation sources in low-voltage distribution grids, electric vehicles, and new appliances from the consumer side can generate short repetitive overloads on the low-voltage cable network. This work investigates the change in the dielectric properties of low-voltage cable insulation caused by short-term overloads, examining how the cable structure affects the dielectric characteristics of the cable specimens in the case of cyclic short-term thermal aging. PVC-insulated low-voltage cable samples were exposed to an accelerated aging test in a temperature-controlled oven after changing their structures by removing different layers. Three aging cycles, each of six hours, were applied to the samples. After each cycle, the tan δ and capacitance were measured by an Omicron DIRANA Dielectric Response Analyzer in the laboratory at room temperature 24 ± 0.5 °C. Furthermore, the polarization and depolarization currents were also studied. The results show that changing the cable structure impacts the dielectric parameters; in particular, the effect of the belting layer is significant. From the point of view of aging, the PVC belting layer protects the diffusion of the plasticizers of the inner structure. The findings of the study show that an asymmetric aging phenomenon can be observed in different polymeric components of the cables, even though the cables were aged in an air-circulated oven ensuring a homogeneous temperature distribution in the samples.

15 March 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Semih BalSemih Bal
Semih Bal
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
The distribution grid comprises cables with diverse constructions. The insulating material used in low-voltage (LV) distribution cables is predominantly PVC. Furthermore, the presence of cables with different structures in the grid poses challenges in detecting the aging of the cable network. Finding a universal and dependable condition-monitoring technique that can be applied to various types of cables is indeed a challenge. The diverse construction and materials used in different cables make it difficult to identify a single monitoring approach that can effectively assess the condition of all cables. To address this issue, this study aims to compare the thermal aging behavior of different LV distribution cables with various structures, i.e., one cable contains a PVC belting layer, while the other contains filler material. The growing adoption of distributed generation sources, electric vehicles, and new consumer appliances in low-voltage distribution grids can lead to short, repetitive overloads on the low-voltage cable network. Hence, these cable samples were exposed to short-term cyclic accelerated aging in the climate chamber at 110 °C. The cable’s overall behavior under thermal stress was evaluated through frequency and time domain electrical measurements (including tan δ and extended voltage response) and a mechanical measurement (Shore D). The tan δ was measured in the frequency range of 20 Hz–500 kHz by using the Wayne-Kerr impedance analyzer. The extended voltage response measurement was conducted using a C# application developed in-house specifically for laboratory measurements in the .NET environment. The study observed a strong correlation between the different measurement methods used, indicating that electrical methods have the potential to be adopted as a non-destructive condition-monitoring technique.

24 April 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Semih BalSemih Bal
Semih Bal
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
The widespread use of renewable energy sources has considerably expanded distributed generation. An unbalanced load on distribution cables may also result from the recent increase in novel appliances and electric vehicles, the reverse power flow may create short-term overloads. These transient overloads increase the temperature for a short time beyond the limit, which causes degradation. However, the temperature distribution on the cable is not even. Therefore, the cable components are not degraded evenly and similarly. This publication describes the change in electrical properties of low-voltage cables caused by short-term cyclic artificial ageing to track the impact of these brief temperature rises. This study examines how cable structure affects the dielectric characteristics of cable specimens. Four cable samples, each measuring 50 cm in length (SZAMKAM 0.6/1 kV 16 mm2× 4 manufactured by Prysmian MKM Kft, Hungary) put through an accelerated ageing test in a temperature-controlled oven after changing their structures by removing their layers. Three rounds, each of six hours, accelerated thermal ageing were applied. After each round of ageing, the dielectric parameter tanδ and capacitance were measured by Dirana Dielectric Response Analyzer in the laboratory at room temperature 24±0.5∘C. Furthermore, the polarization and depolarization currents were also studied. The results show that changing the cable structure impacts the dielectric parameters, especially the effect of belting layer is significant. From point of view of aging the PVC belting layer protects the diffusion of plasticizers of inner structure.