Zoltan Adam Tamus

Dr. Zoltan Adam Tamus

Budapest University of Technology and Economics, Faculty of Electrical Engineering and Informatics
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2018 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Jaroslav HornakJaroslav Hornak
Jaroslav Hornak
Pavel TrnkaPavel Trnka
Pavel Trnka
Petr KadlecPetr Kadlec
Petr Kadlec
Ondřej MichalOndřej Michal
Ondřej Michal
VMVáclav Mentlík
Václav Mentlík
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
Composite insulation materials are an inseparable part of numerous electrical devices because of synergy effect between their individual parts. One of the main aims of the presented study is an introduction of the dielectric properties of nanoscale magnesium oxide powder via Broadband Dielectric Spectroscopy (BDS). These unique results present the behavior of relative permittivity and loss factor in frequency and temperature range. Following the current trends in the application of inorganic nanofillers, this article is complemented by the study of dielectric properties (dielectric strength, volume resistivity, dissipation factor and relative permittivity) of epoxy-based composites depending on the filler amount (0, 0.5, 0.75, 1 and 1.25 weight percent). These parameters are the most important for the design and development of the insulation systems. The X-ray diffraction patterns are presented for pure resin and resin with optimal filler amount (1 wt %), which was estimated according to measurement results. Magnesium oxide nanoparticles were also treated by addition of silane coupling agent ( γ -Glycidoxypropyltrimethoxysilane), in the case of optimal filler loading (1 wt %) as well. Besides previously mentioned parameters, the effects of surface functionalization have been observed by two unique measurement and evaluation techniques which have never been used for this evaluation, i.e., reduced resorption curves (RRCs) and voltage response method (VR). These methods (developed in our departments), extend the possibilities of measurement of composite dielectric responses related to DC voltage application, allow the facile comparability of different materials and could be used for dispersion level evaluation. This fact has been confirmed by X-ray diffraction analyses.

27 November 2020 in Polymers
Verified
Journal Article
Open access
PDF file
GCGergely Csányi
Gergely Csányi
Semih BalSemih Bal
Semih Bal
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
The effect of short-term (3- and 6-h-long) periodic thermal aging was investigated at three different temperatures on PVC cables and PVC films. Three different temperatures (110, 125, and 140 °C) were used for aging PVC cables and one (110 °C) for PVC films. PVC films were prepared for the investigation containing 0, 30, 40, and 50 weight percent of dioctyl phthalate plasticizer (DOP). The effect of short-term thermal aging was monitored by electrical (dielectric spectrum and voltage response measurement) and mechanical (Shore D hardness) methods. From the loss factor measurements, different deducted quantities were calculated and compared with Shore D hardness, which has been shown to be a parameter reflecting the effect of short-term thermal aging on PVC insulation. The measurements revealed that Shore D hardness is not the best property for monitoring aging. Instead, increasing dissipated power and the shifting behavior of tan δ–frequency curves proved to be the best phenomena for assessing the impact of thermal aging. Simple deducted quantities may provide a basis for following short-term thermal aging.

23 September 2019 in Periodica Polytechnica Electrical Engineering and Computer Science
Verified
Journal Article
Closed access
PDF file
Ehtasham MustafaEhtasham Mustafa
Ehtasham Mustafa
Ramy Saad Abdelatty AfiaRamy Saad Abdelatty Afia
Ramy Saad Abdelatty Afia
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
The low voltage cables in the nuclear power plant have the same importance as veins have in the human body. Since, the cables inside the containment are under a number of environmental stress, out which the thermal and radiation stresses are important and become more effective with the presence of oxygen. These stresses cause the degradation of the insulation and hence may lead to insulation failure. To study the behavior of the cables under the nuclear power plant environmental stress, the cables are subjected to accelerated aging tests in laboratories which helps in determining their withstand capacity and degradation behavior in the harsh thermal-radiation environment. In this paper, the accelerated aging tests conditions are discussed with the focus on the role of certain uncertainty factors which effect the aging markers during the condition monitoring of the insulation material of cable after the accelerated aging tests. This review has been put into a framework to better understand the aging process in the low voltage nuclear power plant cables. In the conclusion part, some future directions in the field of the thermal-radiation multi-stress accelerated aging tests and condition monitoring techniques are also identified.

2 November 2015 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
Tamás OroszTamás Orosz
Tamás Orosz
ASAdam Sleisz
Adam Sleisz
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
Because of the strong competition in the equipment market, the aim of the manufacturers is to reduce the product price as much as possible, fulfill the high-quality standards, and improve the reliability and efficiency of the transformers. The capitalization of the costs enables to handle the different economic and technological parameters together in the same cost function. Large power autotransformers are usually designed for specific economic and technical conditions specified by the customer. At the tender design stage, the most economical solution has to be found in a limited time, and a great number of feasible transformer designs have to be compared to find the optimal solution. Nowadays, the solution of this design process is mainly based on the experience of the transformer designer, but mathematical programming models can facilitate the process. It is well known that the design of shell-type power transformers can be optimized by geometric programming. The constructed models of geometric programming can be solved accurately with the interior-point-method-based solvers. According to the results, this kind of modeling is not applicable for the core-form transformers. However, with branch-and-bound search, the geometric programming method can also be used for these cases. This paper introduces a new algorithm, which can also handle the autotransformer designs with different positions of the regulating winding by applying a more general metaheuristic routine to perform the calculation of the short-circuit impedance.

29 October 2020 in Electrical Engineering
Verified
Journal Article
Open access
PDF file
Ehtasham MustafaEhtasham Mustafa
Ehtasham Mustafa
Ramy Saad Abdelatty AfiaRamy Saad Abdelatty Afia
Ramy Saad Abdelatty Afia
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
This paper discusses the effect of thermal stress on the electrical properties, conduction and polarization, of low-voltage CSPE/XLPE-based power cables used in a nuclear power plant. The cables were subjected to an accelerated thermal stress at 120°C for an equivalent service period of 20, 40, 60 and 80 years. The capacitance, tanδ, resistivity at different frequencies and extended voltage response were the methods used for the investigation. A significant variation in the values of tanδ at low frequency, i.e., at 100 Hz, was observed. For the extended voltage response measurement, the decay voltage slope increased, showing the increase in the conduction particles inside the insulation material. While the decrease in return voltage slope showed that the slow polarization processes occurring at very low frequencies were decreased with aging. A strong correlation between the tanδ and decay voltage slope was also observed, which increased as the insulation aging increased. The results showed that the methods could be used for the in situ measurement of conduction and polarization phenomenon in the low-voltage cables, and hence helping in the assessment of the condition of cable insulation.

20 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
Ehtasham MustafaEhtasham Mustafa
Ehtasham Mustafa
Ramy Saad Abdelatty AfiaRamy Saad Abdelatty Afia
Ramy Saad Abdelatty Afia
ONOumaima Nouini
Oumaima Nouini
Zoltan Adam TamusZoltan Adam Tamus
Zoltan Adam Tamus
In a nuclear power plant environment, low-voltage cables experience different stresses during their service life which challenge their integrity. A non-destructive and reliable condition monitoring technique is desired to determine the state of these low-voltage cables during service and for the life extension of nuclear power plants. Hence, in this research work, an EPR/CSPE-based low-voltage cable was exposed to γ-rays for five different absorbed doses. The overall behavior of the cable under stress was characterized by frequency and time domain electrical measurements (capacitance, tan δ, and Extended Voltage Response) and a mechanical measurement (elongation at break). Significant variations in the electrical parameters were observed, as was a decline in the elongation at break values. A strong correlation between the measurement methods was observed, showing the ability of the electrical methods to be adopted as a non-destructive condition monitoring technique.