Ultrasound localization microscopy (ULM) based on ultrafast ultrasound imaging of circulating microbubbles (MB) can image microvascular blood flows in vivo up to the micron scale. Takayasu arteritis (TA) has an increased vascularisation of the thickened arterial wall when active. We aimed to perform vasa vasorum ULM of the carotid wall and demonstrate that ULM can provide imaging markers to assess the TA activity. Patients with TA were consecutively included with assessment of activity by the National Institute of Health criteria: 5 had active TA (median age 35.8 [24.5-46.0] years) and 11 had quiescent TA (37.2 [31.7-47.3] years). ULM was performed using a 6.4 MHz probe and a dedicated imaging sequence (plane waves with 8 angles, frame rate 500 Hz), coupled with the intravenous injection of MB. Individual MB were localised at a subwavelength scale then tracked, allowing the reconstruction of the vasa vasorum flow anatomy and velocity. ULM allowed to show microvessels and to measure their flow velocity within the arterial wall. The number of MB detected per second in the wall was 121 [80-146] in active cases vs. 10 [6-15] in quiescent cases (p = 0.0005), with a mean velocity of 40.5 [39.0-42.9] mm.s-1 in active cases. ULM allows visualisation of microvessels within the thickened carotid wall in TA, with significantly greater MB density in active cases. ULM provides a precise visualisation in vivo of the vasa vasorum and gives access to the arterial wall vascularisation quantification. French Society of Cardiology. ART (Technological Research Accelerator) biomedical ultrasound program of INSERM, France.
Importance: High lipoprotein(a) (Lp[a]) levels are involved in the development of cardiovascular events, particularly in myocardial infarction, stroke, and peripheral artery disease. Studies assessing the Lp(a) levels associated with adverse lower-limb events are lacking.Objective: To assess the association between Lp(a) levels and incidence of major adverse limb events in unselected hospitalized patients.Design, Setting, and Participants: This large retrospective monocentric cohort study was conducted from January 1, 2000, to December 31, 2020. Data were derived from the clinical information system of the Hôpital Européen Georges-Pompidou, a Paris-based university hospital. Patients who underwent at least 1 Lp(a) measurement at the center during the study period were included. Patients who had no follow-up data or who had the first Lp(a) measurement after the study outcome had occurred were excluded. Data analyses were performed from May 2021 to January 2022.Main Outcomes and Measures: The primary outcome was the first inpatient major adverse limb event, defined as a major amputation, peripheral endovascular revascularization, or peripheral surgical revascularization, during follow-up. Secondary outcomes included individual components of the primary outcome. Lipoprotein(a) levels were categorized as follows: normal (<50 mg/dL), high (50 to <134 mg/dL), and very high (≥134 mg/dL); to convert Lp(a) values to milligrams per liter, multiply by 0.1.Results: A total of 16 513 patients (median [IQR] age, 58.2 [49.0-66.7] years; 9774 men [59.2%]) were included in the cohort. The median (IQR) Lp(a) level was 24 (10.0-60.0) mg/dL. The 1-year incidence of major adverse limb event was 2.44% in the overall population and 4.54% among patients with very high Lp(a) levels. High (adjusted accelerated failure time [AFT] exponential estimate: 0.43; 95% CI, 0.24-0.78; Benjamini-Hochberg–corrected P = .01) and very high (adjusted AFT exponential estimate: 0.17; 95% CI, 0.07-0.40; Benjamini-Hochberg–corrected P < .001) Lp(a) levels were independently associated with an increased risk of major adverse limb event.Conclusions and Relevance: Results of this study showed that higher Lp(a) levels were independently associated with an increased risk of a major adverse limb event in hospitalized patients. The Lp(a) measurement needs to be taken into account to improve lower-limb vascular risk assessment.
Blood pressure measurement is the most widely performed clinical exam to predict mortality risk. The gold standard for its noninvasive assessment is the auscultatory method, which relies on listening to the so-called “Korotkoff sounds” in a stethoscope placed at the outlet of a pneumatic arm cuff. However, more than a century after their discovery, the origin of these sounds is still debated, which implies a number of clinical limitations. We imaged the Korotkoff sound generation in vivo at thousands of images per second using ultrafast ultrasound. We showed with both experience and theory that Korotkoff sounds are paradoxically not sound waves emerging from the brachial artery but rather shear vibrations conveyed in surrounding tissues by the nonlinear pulse wave propagation. When these shear vibrations reached the stethoscope, they were synchronous, correlated, and comparable in intensity with the Korotkoff sounds. Understanding this mechanism could ultimately improve blood pressure measurement and provide additional understanding of arterial mechanical properties.
Doppler ultrasound is the premier modality to analyze blood flow dynamics in clinical practice. With conventional systems, Doppler can either provide a time-resolved quantification of the flow dynamics in sample volumes (spectral Doppler) or an average Doppler velocity/power [color flow imaging (CFI)] in a wide field of view (FOV) but with a limited frame rate. The recent development of ultrafast parallel systems made it possible to evaluate simultaneously color, power, and spectral Doppler in a wide FOV and at high-frame rates but at the expense of signal-to-noise ratio (SNR). However, like conventional Doppler, ultrafast Doppler is subject to aliasing for large velocities and/or large depths. In a recent study, staggered multi-pulse repetition frequency (PRF) sequences were investigated to dealias color-Doppler images. In this work, we exploit the broadband nature of pulse-echo ultrasound and propose a dual-wavelength approach for CFI dealiasing with a constant PRF. We tested the dual-wavelength bandpass processing, in silico, in laminar flow phantom and validated it in vivo in human carotid arteries ( n = 25). The in silico results showed that the Nyquist velocity could be extended up to four times the theoretical limit. In vivo, dealiased CFI were highly consistent with unfolded Spectral Doppler ( r 2 =0.83, y=1.1x+0.1, N=25) and provided consistent vector flow images. Our results demonstrate that dual-wavelength processing is an efficient method for high-velocity CFI.