The Industry 5.0 paradigm has a human-centered vision of the industrial scenario and foresees a close collaboration between humans and robots. Industrial manufacturing environments must be easily adaptable to different task requirements, possibly taking into account the ergonomics and production line flexibility. Therefore, external sensing infrastructures such as cameras and motion capture systems may not be sufficient or suitable as they limit the shop floor reconfigurability and increase setup costs. In this paper, we present the technological advancements leading to the realization of ProxySKIN, a skin-like sensory system based on networks of distributed proximity sensors and tactile sensors. This technology is designed to cover large areas of the robot body and to provide a comprehensive perception of the surrounding space. ProxySKIN architecture is built on top of CySkin, a flexible artificial skin conceived to provide robots with the sense of touch, and arrays of Time-of-Flight (ToF) sensors. We provide a characterization of the arrays of proximity sensors and we motivate the design choices that lead to ProxySKIN, analyzing the effects of light interference on a ToF, due to the activity of other sensing devices. The obtained results show that a large number of proximity sensors can be embedded in our distributed sensing architecture and incorporated onto the body of a robotic platform, opening new scenarios for complex applications.
This paper describes the optimal implementation of three newly conceived sensors for both health and environmental applications, utilizing a wide range of detection methods and complex nanocomposites. The first one is inorganic and based on matrices of calcium oxide, the second is based on protein arrays and a third one is based on Langmuir-Blodgett laccase multi-layers. Special attention was paid to detecting substances significant to the environment (such as carbon dioxide) and medicine (drug administration, cancer diagnosis and prognosis) by means of amperometric, quartz crystal microbalance with frequency (QCM_F) and quartz crystal microbalance with dissipation monitoring (QCM_D) technologies. The resulting three implemented nanosensors are described here along with proofs of principle and their corresponding applications.
This work presents a feedback closed-loop platform to be used for viscosity or viscoelasticity sensing of Newtonian or non-Newtonian fluids. The system consists of a photothermally excited microcantilever working in a digital Phase-Locked Loop, in which the phase between the excitation signal to the cantilever and the reference demodulating signals is chosen and imposed in the loop. General analytical models to describe the frequency and amplitude of oscillation of the cantilever immersed in viscous and viscoelastic fluids are derived and validated against experiments. In particular, the sensitivity of the sensor to variations of viscosity of Newtonian fluids, or to variations of elastic/viscous modulus of non-Newtonian fluids, are studied. Interestingly, it is demonstrated the possibility of controlling the sensitivity of the system to variations of these parameters by choosing the appropriate imposed phase in the loop. A working point with maximum sensitivity can be used for real-time detection of small changes of rheological parameters with low-noise and fast-transient response. Conversely, a working point with zero sensitivity to variations of rheological parameters can be potentially used to decouple the effect of simultaneous external factors acting on the resonator.
A significant upgrading of a recently introduced biosensor system, called potentiometric alternating biosensor is presented. The transducer consists of a light‐addressable silicon chip, which provides regions properly modified and functionalized to yield sensitivity to either pH or redox potentials. The computer controlled system drives an array of light sources, allowing two‐dimensional signal acquisition and processing. The system can provide multiparameter information related to the local modifications made on the sensing surface of the transducer. This work presents a detailed description of the measuring principles and the spatial resolution obtainable with the system. In addition, the complete circuit design is presented, both for signal conditioning, and for the bidimensional matrix addressing. A typical experiment for selective measurements is presented.
Starting from the late 1980’s, scanning probe microscopy has progressively diffused in Italy until today. In this paper, we provide a brief account of the main historical events and a current picture of the distribution of the active groups. A survey was prepared by LimeSurvey, made of six sections asking for personal and institutional data, human resources, equipment available, fields of interest, research projects, educational/dissemination activities, and two relevant publications in the last six years. It turns out that the Italian community includes more than seventy groups and two companies. It is widely diffused, although mostly concentrated near large academic and research institutions, often in locations where prominent Italian researchers have operated. This community is active in many scientific fields and can produce research of high international quality. It shows a wide competence, as proven by the list of research works published in journals ranked within the top 20% class. The diffusion of SPM microscopes in industry is still sporadic, possibly due to extensive collaborations between the research institutions and industries themselves. The authors hope that this work might be useful to the community and beyond, and that it might stimulate the formation of a more structured network.