Ming Deng

Ms. Ming Deng


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2013 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MDMing Deng
Ming Deng
XSXiaokang Sun
Xiaokang Sun
MHMeng Han
Meng Han
DLDecai Li
Decai Li
We report a magnetic-field sensor by merging the advantages of optical fiber Michelson interferometers with that of magnetic fluid. Compact and low-cost optical fiber Michelson interferometers were first fabricated by a high-frequency CO2 laser, and then they were inserted into glass capillaries with water-based Fe3O4 magnetic fluid as sensing elements. The sensing characteristics have been investigated and the experimental results show that the reflective spectrum of the fiber-magnetic sensor linearly shifted with the change of the magnetic-field strength that is perpendicular to the axial of the devices. The fiber-magnetic sensor with interference arm’s diameter of 50 μm is most sensitive to the external magnetic field, and the sensitivity is up to 64.9  pm/mT, which is 20 times higher than that of 125 μm diameter.

10 January 2022 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
SGSanfeng Gu
Sanfeng Gu
Danqi FengDanqi Feng
Danqi Feng
TZTianheng Zhang
Tianheng Zhang
SDShudan Deng
Shudan Deng
MLMeng Li
Meng Li
MDMing Deng
Ming Deng
A taper-based in-line Mach-Zehnder interferometer (MZI) coated with the magnetic fluids (MFs) is designed and experimentally verified for the highly sensitive magnetic field measurement. The effect of waist diameter on the characteristic parameters of transmission modes is numerically analyzed by the finite element method (FEM). The sensing MZI (S-MZI) with a waist diameter of ∼8.92 μm is fabricated, in which the multi-mode interference occurs between the fundamental mode (HE11) and cladding modes (HE21 and TM01 modes). The S-MZI has the average sensitivities of 1.180 and 1.305 nm/mT near 1550 nm as the magnetic field increases and decreases in the range of 10.15∼30.44 mT. In order to further improve the measurement sensitivity of the magnetic field, a cascaded MZI (C-MZI) based on the Vernier effect is proposed, which is composed of a reference MZI (R-MZI) without MFs connected in series with the above S-MZI. An evident envelope and shift influenced by the external magnetic field is observed in the transmission spectra of the C-MZI, resulting in the sensitivity being elevated by an amplification factor. The C-MZI shows the average sensitivities of −5.148 and −5.782 nm/mT near 1500 nm, respectively, being ∼4.77 and 4.83 times of those in the single S-MZI. Therefore, the proposed device may have broad applications in the magnetic field measurement in view of the advantages of high sensitivity, low cost, small volume, and simple fabrication.

13 June 2012 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
LXLai-Cai Xu
Lai-Cai Xu
MDMing Deng
Ming Deng
Dewen DuanDewen Duan
Dewen Duan
WWWei-Ping Wen
Wei-Ping Wen
MHMeng Han
Meng Han

12 June 2022 in Photonic Sensors
Verified
Journal Article
Open access
PDF file
WSWei Sun
Wei Sun
XLXiangyu Liu
Xiangyu Liu
MDMing Deng
Ming Deng
A novel fiber-optic magnetic field sensor with high interrogation speed and resolution by using an etched fiber Bragg grating (FBG) in conjunction with a dual-loop optoelectronic oscillator (OEO) is proposed and experimentally demonstrated. A commercial FBG is firstly dipped into mixed hydrofluoric acid solution to remove the cladding layer and then is embedded with the magnetic fluid (MF) as a sensing element. The central wavelength reflected from the FBG is related to the overall time delay of the dual-loop OEO, which determines the oscillating frequency of the OEO. Therefore, the magnetic field can be estimated by measuring the oscillating frequency shift of OEO. The experimental results show that the oscillating frequency linearly increases with the increment of the magnetic field, achieving the sensitivity of 16.3 Hz/Oe with a R -square of 0.991 in the range of 5 mT–10 mT. In addition, the maximum error is within ±0.05 mT in the range of 7 mT–8 mT, which offers potentials in many fields where the high-precision magnetic field measurement is required.

1 April 2022 in Optik
Verified
Journal Article
Closed access
SGSanfeng Gu
Sanfeng Gu
WSWei Sun
Wei Sun
MLMeng Li
Meng Li
ZLZhonghao Li
Zhonghao Li
XNXinhao Nan
Xinhao Nan
MDMing Deng
Ming Deng

21 February 2022 in Plasmonics
Verified
Journal Article
Closed access
PDF file
SGSanfeng Gu
Sanfeng Gu
WSWei Sun
Wei Sun
MLMeng Li
Meng Li
TZTianheng Zhang
Tianheng Zhang
MDMing Deng
Ming Deng