James J. Sohn

James J. Sohn

Auto-generated profile, based on publicly available information

James J. Sohn

Department of Radiation and Cellular Oncology University of Chicago Chicago Illinois USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
JWJing Wang
Jing Wang
Xiaofeng YangXiaofeng Yang
Xiaofeng Yang
BZBoran Zhou
Boran Zhou
JSJames J. Sohn
James J. Sohn
Jun ZhouJun Zhou
Jun Zhou
TLTian Liu
Tian Liu
Ultrasound imaging of the lung has played an important role in managing patients with COVID-19–associated pneumonia and acute respiratory distress syndrome (ARDS). During the COVID-19 pandemic, lung ultrasound (LUS) or point-of-care ultrasound (POCUS) has been a popular diagnostic tool due to its unique imaging capability and logistical advantages over chest X-ray and CT. Pneumonia/ARDS is associated with the sonographic appearances of pleural line irregularities and B-line artefacts, which are caused by interstitial thickening and inflammation, and increase in number with severity. Artificial intelligence (AI), particularly machine learning, is increasingly used as a critical tool that assists clinicians in LUS image reading and COVID-19 decision making. We conducted a systematic review from academic databases (PubMed and Google Scholar) and preprints on arXiv or TechRxiv of the state-of-the-art machine learning technologies for LUS images in COVID-19 diagnosis. Openly accessible LUS datasets are listed. Various machine learning architectures have been employed to evaluate LUS and showed high performance. This paper will summarize the current development of AI for COVID-19 management and the outlook for emerging trends of combining AI-based LUS with robotics, telehealth, and other techniques.

7 July 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
JHJoseph Mark Harms
Joseph Mark Harms
LMLuke Maloney
Luke Maloney
JSJames J. Sohn
James J. Sohn
AEAnna Erickson
Anna Erickson
YLYuting Lin
Yuting Lin
RZRongxiao Zhang
Rongxiao Zhang
In proton-based radiotherapy, proton radiography could allow for direct measurement of the water-equivalent path length (WEPL) in tissue, which can then be used to determine relative stopping power (RSP). Additionally, proton radiographs allow for imaging in the beam’s-eye-view. In this work, a proton radiography technique using a flat-panel imager and a pencil-beam scanning (PBS) system is demonstrated in phantom. Proton PBS plans were delivered on a Varian ProBeam system to a flat-panel imager. Each proton plan consisted of energy layers separated by 4.8 MeV, and a field size of 25 cm × 25 cm. All measured data is binned into a layer-by-layer delivery in post processing. To build a calibration curve correlating detector response to WEPL, the plans were delivered to slabs of solid water of increasing thickness. Pixel-by-pixel detector response in the time/energy domain is then fit as a function of WEPL. Tissue equivalent phantoms are imaged for evaluation of WEPL accuracy. A spatial resolution phantom and a head phantom are also imaged. For all experiments, the detector was run with an effective pixel size of 0.4 mm × 0.4 mm. The proposed method reconstructed RSP with mean errors of 2.65%, −0.14%, and 0.61% for lung, soft tissue, and bone, respectively. In a 40 mm thick spatial resolution phantom, a 2 mm deep pinhole with 1 mm diameter can be seen. The accuracy and spatial resolution of the method show that it could be implemented for patient position verification. Further development could lead to patient-specific verification of RSP to be used for treatment guidance.

6 June 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
RJRunyu Jiang
Runyu Jiang
MMMalvern Madondo
Malvern Madondo
XZXiaoman Zhang
Xiaoman Zhang
YSYuan Shao
Yuan Shao
MMMohammadamin Moradi
Mohammadamin Moradi
ZTZhen Tian
Zhen Tian
Objective. High-dose-rate (HDR) brachytherapy is integral to the standard-of-care for locally advanced cervical cancer (LACC). Currently, selection of brachytherapy applicators relies on physician’s clinical experience, which can lead to variability in treatment quality and outcomes. This study presents a deep learning-based decision-support tool for selecting between interstitial Syed applicators and intracavitary tandem & ovoids applicators. Approach. The network architecture consists of six 3D convolutional-pooling-rectified linear unit blocks, followed by a fully connected block. The input to the network includes three channels: a 3D contour mask of clinical target volume (CTV), organs at risk (OAR), and central tandem, and two 3D distance maps of CTV and OAR voxels relative to the tandem’s central axis. The network outputs a probability score, indicating the suitability of Syed applicators. Binary cross-entropy loss combined with L 1 regularization was used for network training. Main results. A retrospective study was performed on 184 LACC patients with 422 instances of applicator insertion. The data was divided into three sets: Dataset-1 of 163 patients with 372 insertions for training and hyperparameter tuning, Dataset-2 of 17 patients with 36 insertions and Dataset-3 of four complex cases with 14 insertions for testing. Five-fold cross-validation was performed on Dataset-1, during which hyperparameters were heuristically tuned to optimize classification accuracy across the folds. The highest average accuracy was 92.1 ± 3.8%. Using the hyperparameters that resulted in this highest accuracy, the final model was then trained on the full Dataset-1, and evaluated on the other two independent datasets, achieving 96.0% accuracy, 90.9% sensitivity, and 97.4% specificity. Significance. These results demonstrate the potential of our model as a quality assurance tool in LACC HDR brachytherapy, providing feedback on physicians’ applicator choice and supporting continuous improvement in decision-making. Future work will focus on collecting more data for further validation and extending its application for prospective applicator selection.

16 March 2020
Verified
Conference Paper
Closed access
PDF file
JSJames Sohn
James Sohn
WNWei Nie
Wei Nie
SAStephen M. Avery
Stephen M. Avery
XHXiuxiu He
Xiuxiu He
Jun ZhouJun Zhou
Jun Zhou
TLTian Liu
Tian Liu
Protoacoustics, the measurement of the pressure waves emitted by thermal expansion resulting from proton dose deposition, may be used to obtain the depth of the Bragg-peak (BP) by measuring the time-of-flight of the pressure wave. However, using the method in the clinic has a drawback since numerous measured signals were averaged to identify the accurate signal peak from the indistinguishable noises. We proposed a wavelet-based denoising method to significantly reduce noise in collected protoacoustic signals and improve the BP identification accuracy with fewer signal averages. The average 1024 signal, which has been used in the published study, was used as the reference to identify the accurate acoustic location. We used Daubechies (db) 4 wavelet transform to decompose the collected signals to recover the useful protoacoustic signals. Our approach was able to identify the BP signal up to the average 8 signals that correspond to the dose (<1.5 Gy). This denoising technique would be useful for future 2D/3D protoacoustic imaging and make protoacoustic clinically useful for proton range verification.

22 June 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
JSJames J. Sohn
James J. Sohn
SLSara N Lim
Sara N Lim
Indra J DasIndra J Das
Indra J Das
PYPoonam Yadav
Poonam Yadav
Periodic imaging quality assurance (QA) of magnetic resonance imaging linear accelerator (MRL) is critical. The feasibility of a new MRL imaging phantom used for QA in the low field was evaluated with automated image analysis of various parameters for accuracy and reproducibility. The new MRL imaging phantom was scanned across every 30 degrees of the gantry, having the on/off state of the linac in a low-field MRL system using three magnetic resonance imaging sequences: true fast imaging with steady-state precession (TrueFISP), T1 weighted (T1W), and T2 weighted (T2W). The DICOM files were used to calculate the imaging parameters: geometric distortion, uniformity, resolution, signal-to-noise ratio (SNR), and laser alignment. The point spread function (PSF) and edge spread function (ESF) were also calculated for resolution analysis. The phantom data showed a small standard deviation - and high consistency for each imaging parameter. The highest variability in data was observed with the true fast imaging sequence at the calibration angle, which was expected because of low resolution and short scan time (25 sec). The mean magnitude of the largest distortion measured within 200 mm diameter with TrueFISP was 0.31 ± 0.05 mm. The PSF, ESF, signal uniformity, and SNR measurements remained consistent. Laser alignment traditional offsets and angular deviation remained consistent. The new MRL imaging phantom is reliable, reproducible, time effective, and easy to use for a 0.35 T MRL system. The results promise a more streamlined, time-saving, and error-free QA process for low-field MRL adapted in our clinical setting.

28 May 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
JSJames J Sohn
James J Sohn
Indra J DasIndra J Das
Indra J Das
Background. Small field dosimetry presents unique challenges with source occlusion, lateral charged particle equilibrium and detector size. As detector volume decreases, signal strength declines while noise increases, deteriorating the signal-to-noise ratio (SNR). This issue may be compounded by triaxial cables connecting detectors to electrometers. However, effects of cables, critical for precision dosimetry, are often overlooked. There is a need to evaluate triaxial cable and detector impacts on SNR in small fields. The purpose of this study is to evaluate the influence of triaxial cables and microdetectors on signal-to-noise ratios in small-field dosimetry. This study also aims to establish the importance of cable quality assurance for measurement accuracy. Methods. Six 9.1 m length triaxial cables from different manufacturers were tested with six microdetectors (microDiamond, PinPoint, EDGE, Plastic scintillator, microSilicon, SRS-Diode). A 6 MV photon beam (TrueBeam) was used, with a water phantom at 5 cm depth with 0.5 × 0.5 cm2 to 10 × 10 cm2 fields at 600 MU min−1. Readings were acquired using cable-detector permutations with a dedicated electrometer (except the scintillator which has its own). Cables had differing connector types, conductor materials, insulation, and diameters. Detectors had various sensitive volumes, materials, typical signals, and bias voltages. Results. Normalized field output correction factors (FOFs) relative differences of 13.4% and 4.6% between the highest and lowest values across triaxial cables for 0.5 × 0.5 cm2 and 1 × 1 cm2 fields, respectively. The maximum difference in FOF between any cable-detector combinations was 0.2% for the smallest field size. No consistent FOF trend was observed across all detectors when increasing cable diameter. Additionally, the non-normalized FOF differences of 0.9% and 0.3% were observed between cables for 0.5 × 0.5 cm2 and 1 × 1 cm2 fields, respectively. Conclusions. Regular triaxial cable quality assurance is critical for precision small field dosimetry. A national protocol is needed to standardize cable evaluations/calibrations, particularly for small signals (<pC) from modern detectors. This could enhance measurement accuracy and treatment delivery with advanced small-field radiotherapy techniques that promise improved patient outcomes. Further studies should expand detector and cable models tested across institutions to establish robust quality control guidelines.