Ping Hu

Dr. Ping Hu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
PHPing Hu
Ping Hu
JTJoseph A. Turner
Joseph A. Turner
Ultrasonic scattering occurs when elastic waves interact with interfaces within heterogeneous media. Diffuse ultrasonic backscatter measurements are used to capture the effective grain scattering within a polycrystal for extracting microstructural information. Recently, a mode-conversion scattering model was developed to describe the longitudinal-to-transverse ultrasonic scattering within polycrystalline materials and successfully applied to determine the material spatial correlation length L by fitting experimental results with the theoretical model. The mode-conversion model may allow additional microstructural information, such as grain shape, to be assessed. In this article, a theoretical extension of the previous mode-conversion ultrasonic scattering model is presented. The transverse-to-transverse (T-T) scattering can be measured by an experimental configuration with both source and receiving transducers oriented at angles between the first and second critical angles, including pitch-catch and pulse-echo measurements. The model is used to determine the correlation length from a sample of 1040 steel through pulse-echo T-T scattering measurements using 7.5 and 10 MHz transducers. The results show that the derived T-T model works well for lower frequencies but the results for higher frequencies reveal deficiencies in the model.

7 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
ZPZhixin Peng
Zhixin Peng
WXWei Xu
Wei Xu
YLYang Liu
Yang Liu
KZKai Zhao
Kai Zhao
PHPing Hu
Ping Hu
Because of rapid heating, cooling, and solidification during metal additive manufacturing (AM), the resulting products exhibit strong anisotropy and are at risk of quality problems from metallurgical defects. The defects and anisotropy affect the fatigue resistance and material properties, including mechanical, electrical, and magnetic properties, which limit the applications of the additively manufactured components in the field of engineering. In this study, the anisotropy of laser power bed fusion 316L stainless steel components was first measured by conventional destructive approaches using metallographic methods, X-ray diffraction (XRD), and electron backscatter diffraction (EBSD). Then, anisotropy was also evaluated by ultrasonic nondestructive characterization using the wave speed, attenuation, and diffuse backscatter results. The results from the destructive and nondestructive methods were compared. The wave speed fluctuated in a small range, while the attenuation and diffuse backscatter results were varied depending on the build direction. Furthermore, a laser power bed fusion 316L stainless steel sample with a series of artificial defects along the build direction was investigated via laser ultrasonic testing, which is more commonly used for AM defect detection. The corresponding ultrasonic imaging was improved with the synthetic aperture focusing technique (SAFT), which was found to be in good agreement with the results from the digital radiograph (DR). The outcomes of this study provide additional information for anisotropy evaluation and defect detection for improving the quality of additively manufactured products.

2 July 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
XLXiongbing Li
Xiongbing Li
DLDuo Lyu
Duo Lyu
Yongfeng SongYongfeng Song
Yongfeng Song
SZShuzeng Zhang
Shuzeng Zhang
PHPing Hu
Ping Hu
Hyunjo JeongHyunjo Jeong
Hyunjo Jeong
Determination of the sensitivity of a transducer is essential in evaluating its central frequency and effective bandwidth, its electroacoustic conversion capability, or the measurement ability of an ultrasonic test system. In this work, a calibration method based on self-reciprocity is proposed for the determination of transducer sensitivity, which can be applied to both planar and focused transducers. The two-port electrical network of the experimental setup is analyzed and a simplified measurement procedure is described in which the ‘impedance mismatch’ problem is solved and only input and output currents are needed. An acoustic transfer function is introduced, both to reduce the effects of wave energy loss on the determination of transducer sensitivity and to help extract the effective geometrical parameters of the transducer through these measured output current signals. The effects of diffraction, attenuation and effective geometrical parameters on sensitivity determination are discussed in this work; the experimental results show that when all these factors are taken into account, accurate sensitivities for both planar and focused transducers can be obtained at various experimental distances.

28 August 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
XZXingyu Zhou
Xingyu Zhou
JXJia Xie
Jia Xie
YHYixuan He
Yixuan He
PHPing Hu
Ping Hu
Laser Powder Bed Fusion (LPBF) has revolutionized high-end manufacturing, particularly in aerospace and biomedical fields. However, internal defects such as pores, cracks, and inclusions compromise the structural integrity and service reliability of LPBF components. Laser ultrasonics, a non-contact, broadband non-destructive testing (NDT) method, offers a promising solution for detecting and characterizing these defects. This study systematically investigated laser ultrasonic testing technology for LPBF-fabricated Ti6Al4V using a combined approach of physics-driven simulation modeling and experimental validation. To accurately model material anisotropy, a finite element model was developed that integrated Voronoi algorithm-generated polycrystalline microstructures with orientation-dependent elastic tensors, providing a comprehensive representation of the material’s microstructural heterogeneity. Simulation results revealed that while sub-100-μm defects yield weak ultrasonic scattering signals, the Synthetic Aperture Focusing Technique (SAFT) markedly improves the detection and imaging performance for such small-scale defects. Experimental validation using a laser ultrasonic system identified a 90 μm internal defect in the LPBF Ti6Al4V specimen, though a 75 μm defect was undetectable. This highlights the need for enhanced sensitivity. A signal processing method combining time-truncation principal component analysis (PCA) with targeted noise reduction and SAFT was proposed to reduce high-frequency noise and improve high-resolution imaging, enhancing defect detection accuracy. This study provides theoretical foundations and technical support for high-precision defect detection in metal additive manufacturing components, with significant implications for quality control in high-end equipment manufacturing.