The development of electric vehicles plays an important role in the field of energy conservation and emission reduction. It is necessary to improve the thermal performance of battery modules in electric vehicles and reduce the power consumption of the battery thermal management system (BTMS). In this study, the heat transfer and flow resistance performance of liquid cold plates with serpentine channels were numerically investigated and optimized. Flow rate (), inlet temperature (Tin), and average heat generation (Q) were selected as key operating parameters, while average temperature (Tave), maximum temperature difference (ΔTmax), and pressure drop (ΔP) were chosen as objective functions. The Response Surface Methodology (RSM) with a face-centered central composite design (CCD) was used to construct regression models. Combined with the multi-objective non-dominated sorting genetic algorithm (NSGA-II), the Pareto-optimal solution was obtained to optimize the operation parameters. The results show that the maximum temperature differences of the cold plate can be controlled within 0.29~3.90 °C, 1.11~15.66 °C, 2.17~31.39 °C, and 3.43~50.92 °C for the discharging rates at 1.0 C, 2.0 C, 3.0 C, and 4.0 C, respectively. The average temperature and maximum temperature difference can be simultaneously optimized by maintaining the pressure drop below 1000 Pa. It is expected that the proposed methods and results can provide theoretical guidance for developing an operational strategy for the BTMS.
An accurate prediction for deep-buried ground heat exchangers (DBGHEs) is the premise for efficient utilization of geothermal energy. Due to the complexity of the geological composition spanning thousands of meters, the configuration of boundary conditions plays a critical role in evaluating DBGHE thermal performance. This paper proposed a three-dimensional model of full-scale DBGHE involving both conductive and convective heat transfer in aquifuge and aquifer layers. The constant inlet temperature and constant heating power boundaries in the DBGHE domain, and the surface–bottom temperature and heat flux boundaries in the rock-soil domain were examined. It was found that the differences in the performance prediction caused by different DBGHE boundary conditions were closely related to the system’s operating time. The relative differences in heat extraction amount and average borehole temperature of 2000 m DBGHE caused by the two inlet boundaries on the 30th day were, respectively, 19.5% and 18.3%, while these differences on the 120th day were decreased to 8.4% and 9.9%, respectively. It was found that the constant inlet temperature boundary was more appropriate than the constant heating power condition for estimating aquifer effects on the performance of DBGHE. For the rock-soil domain, the results showed that the heat extraction amount of DBGHE under the heat flux boundary was 12.6%–13.6% higher than that under the surface–bottom temperature boundary. Particularly, when considering the velocity change of groundwater in the aquifer, the relative difference in heat extraction amount increments caused by the two types of rock-soil boundaries can reach 26.6% on the 120th day. It was also found that the thermal influence radius at the end of a heating season was hardly affected by either the DBGHE inlet or rock-soil domain boundary conditions.
16 February 2023 in Journal of Building Performance Simulation
To simulate the indoor air distribution accurately and quickly, this paper proposed a turbulence calculation model based on the zero-equation model and the SUPG finite element method. The optimal calculation parameters were investigated. The effects of air outlet positions, Reynolds numbers, and obstacle positions on indoor air distribution were studied. The results show that the ranges of Reynolds numbers which satisfy the summer and winter demands of indoor air velocity as the outlet at the right down position are larger than those when the outlet locates left down. When the air outlet locates at the left down position, the velocity non-uniformity coefficients are less than those under the other two conditions. Regardless of whether the air outlet is at the left or right position, the obstacle in the middle of a room can lead to worse velocity uniformity when air velocities in the working zone can meet the velocity demand.