Faruk Emir

Dr. Faruk Emir

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Prosthodontic Research
Verified
Journal Article
Open access
PDF file
FEFaruk Emir
Faruk Emir
SASimel Ayyildiz
Simel Ayyildiz
Purpose: This study aimed to evaluate the trueness and precision of complete-arch models printed with three-dimensional printers via three different printing technologies. Methods: An arch-shaped master model was designed using software (RapidForm XOR2, 3D Systems Inc., USA), and the digital master model was printed 10 times with three-dimensional printers using stereolithography (SLA), direct light processing (DLP), and Polyjet technology (n = 30). The printed models were then scanned with an industrial scanner to create the respective digital models. All digital models were compared with the master model, and an evaluation of the trueness was performed by model superimposition with Geomagic Control software (3D Systems, Rock Hill, SC, USA). Precision was determined for each case by superimposing some combination of the 10 datasets in each group. Results: The trueness of the printed models was 46.2 µm for the DLP printer, 51.6 µm for the SLA printer, and 58.6 µm for the Polyjet printer. The DLP models were significantly better than the Polyjet models (p = .005). However, the Polyjet models (30.4 µm) were more precise than the SLA (37.6 µm) and DLP (43.6 µm) models (p < .001, p = .016). Furthermore, the SLA (11.8 µm) was the most accurate printer in the Z-direction (p = .016, p = .002). Conclusions: The 3D printing technologies showed significant differences in the precision and trueness of complete-arch measurements. Although DLP was more accurate other tested 3D printers, the accuracy of all 3D printed models was within clinical tolerance, and they were clinically acceptable and could be used for the production of fixed restorations.

6 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GCGULSUM CEYLAN
GULSUM CEYLAN
GOGulsum Sayin Ozel
Gulsum Sayin Ozel
GMGözde Memişoglu
Gözde Memişoglu
FEFaruk Emir
Faruk Emir
SŞSevgin Şen
Sevgin Şen
This study evaluates the preference rates for smile designs created by professionals or by Artificial Intelligence (AI) among dentists, dentistry students, and laypeople. Four cases with symmetrical and asymmetrical features were selected based on the Facial Flow (FF) concept from the database of the Smile Designer app regarding anatomical facial points. Two smile designs were created for each selected case: one using Artificial Intelligence (AI) and one created manually. An online survey assessed participants’ preferences for the different smile designs. The chi-square test “Pearson’s and Fisher’s exact test (P)” was used to analyze the survey data. A total of 628 people completed the study. Dentists preferred the manually-created smile design for the first three cases. For Case 4, dentists who used the Smile Designer program preferred the manually-created design (55.88%), while those who did not use the program preferred the AI-generated design (55.84%). There was a significant difference in esthetic perception between dentists and dental students (p = 0.001) and between dentists and laypeople (p = 0.001) for Case 1, only between dentists and dental students (p = 0.003) for Case 2, and only between dentists and laypeople (p = 0.001) for Case 3. Furthermore, we found that females (p = 0.007) and orthodontists (p = 0.025) had a higher preference for the AI-generated design in this case compared to males and other dental specialties for Case 3. While age, education level, and clinical experience did not significantly impact dentists’ preference for manually-created or AI-generated smile designs (p > 0.05), our results suggest that there were some differences in preference for Case 3. Overall, our findings suggest that the use of AI-generated smile designs for symmetric faces is acceptable to both dentists and laypeople and can offer time-saving benefits for clinicians.

1 October 2019 in Journal of Prosthodontic Research
Verified
Journal Article
Closed access
FEFaruk Emir
Faruk Emir
SASimel Ayyıldız
Simel Ayyıldız
The purpose of this study was to evaluate the trueness and precision of eight different extraoral laboratory scanners using three-dimensional (3D) analysis method. An arch-shaped master model was designed with a computer software (Rapidform XOR2) and manufactured with a 3D printer (Projet 3510 MP). Then the master model was digitized with an industrial 3D scanner (ATOS Core 200). With each scanner master model was scanned ten times and stereolithography (.stl) data were imported into 3D analysis software (Geomagic Control). Accuracy was determined with evaluating trueness and precision. Trueness of the scanners were 27.5 μm for 7 series; 30.9 μm for D640; 26.8 μm for D710; 33.3 μm for Activity 102; 32.4 μm for Tizian Smart-Scan; 21.6 μm for NeWay; 26.1 μm for inEOS X5 and 17,47 μm for D2000. 28.2 μm for laser; 32.9 μm for white light and 21.7 μm for blue light scanners. Significant differences were found between scanners (p < .001), (p < .001). Precision of the scanners were 30.1 μm for 7 series; 31.7 μm for D640; 26.3 μm for D710; 22.7 μm for Activity 102; 25.1 μm for Tizian Smart-Scan; 15.7 μm for NeWay; 26.1 μm for inEOS X5; 16.6 μm for D2000. 29.2 μm for laser; 24.4 μm for white light and 19.2 μm for blue light scanners. Significant differences were found between scanners (p < .001), (p = .027). The systems that had the best combination of trueness and precision for complete-arch scanning were D2000 and NeWay. Scanners using blue-light showed more accurate results than the white-light and laser scanners.

15 January 2020 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
SASimel Ayyildiz
Simel Ayyildiz
CŞCem Şahin
Cem Şahin
FEFaruk Emir
Faruk Emir
BEBahadır Ersu
Bahadır Ersu

1 January 2015 in Case Reports in Dentistry
Verified
Journal Article
Open access
PDF file
SASimel Ayyildiz
Simel Ayyildiz
FEFaruk Emir
Faruk Emir
CSCem Sahin
Cem Sahin
Light amplification by stimulated emission of radiation (laser) is one of the most recent treatment modalities in dentistry. Low‐level laser therapy (LLLT) is suggested to have biostimulating and analgesic effects through direct irradiation without causing thermal response. There are few studies that have investigated the efficacy of laser therapy in temporomandibular disorders (TMD), especially in reduced mouth opening. The case report here evaluates performance of LLLT with a diode laser for temporomandibular clicking and postoperative findings were evaluated in two cases of TMD patients. First patient had a history of limited mouth opening and pain in temporomandibular joint (TMJ) region since nine months. Second patient’s main complaint was his restricted mouth opening, which was progressed in one year. LLLT was performed with a 685 nm red probed diode laser that has an energy density of 6.2 J/cm 2 , three times a week for one month, and application time was 30 seconds (685 nm, 25 mW, 30 s, 0.02 Hz, and 6.2 J/cm 2 ) (BTL‐2000, Portative Laser Therapy Device). The treatment protocol was decided according to the literature. One year later patients were evaluated and there were no changes. This application suggested that LLLT is an appropriate treatment for TMD related pain and limited mouth opening and should be considered as an alternative to other methods.

1 January 2018 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
FEFaruk Emir
Faruk Emir
SASimel Ayyildiz
Simel Ayyildiz
CSCem Sahin
Cem Sahin
Emir F, et al. J Adv Prosthodont. 2018 Apr;10(2):93-100. https://doi.org/10.4047/jap.2018.10.2.93