During epidemics or pandemics affecting the respiratory systems, hospital equipment such as ventilators may become insufficient and different solutions can be considered. In fast spreading respiratory illnesses such as COVID-19 due to the rapidly increasing number of patients, ventilatory machine insufficiencies may appear. It may be considered to use one hospital ventilator for more than one patient by dividing the airway of the machine with a specially designed splitter. The aim of this study was to determine whether a ventilator can be modified to provide ventilation of two or more patients simultaneously by using 3D designed and manufactured splitters. A two-port and four-port splitter were designed in Autodesk Fusion 360 computer program and manufactured by 3D printer using PolyJet technology (Stratasys J750). Two sets of splitters were used to adapt to the ventilator during trial process: one for inspiratory and one for expiratory outputs. Two intensive care specialists voluntarily tried this study on themselves. It was concluded from the study that 3D designed and manufactured two-port splitter can be used to separate the airway of a single ventilator to multiple patients within a very limited indication and time interval.
Light amplification by stimulated emission of radiation (laser) is one of the most recent treatment modalities in dentistry. Low‐level laser therapy (LLLT) is suggested to have biostimulating and analgesic effects through direct irradiation without causing thermal response. There are few studies that have investigated the efficacy of laser therapy in temporomandibular disorders (TMD), especially in reduced mouth opening. The case report here evaluates performance of LLLT with a diode laser for temporomandibular clicking and postoperative findings were evaluated in two cases of TMD patients. First patient had a history of limited mouth opening and pain in temporomandibular joint (TMJ) region since nine months. Second patient’s main complaint was his restricted mouth opening, which was progressed in one year. LLLT was performed with a 685 nm red probed diode laser that has an energy density of 6.2 J/cm 2 , three times a week for one month, and application time was 30 seconds (685 nm, 25 mW, 30 s, 0.02 Hz, and 6.2 J/cm 2 ) (BTL‐2000, Portative Laser Therapy Device). The treatment protocol was decided according to the literature. One year later patients were evaluated and there were no changes. This application suggested that LLLT is an appropriate treatment for TMD related pain and limited mouth opening and should be considered as an alternative to other methods.
1 January 2018 in The Journal of Advanced Prosthodontics