Robert Dłucik

Dr. Robert Dłucik


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2023 in Expert Review of Medical Devices
Verified
Journal Article
Closed access
RDRobert Dłucik
Robert Dłucik
BOBogusława Orzechowska-Wylęgała
Bogusława Orzechowska-Wylęgała
DDDaniel Dłucik
Daniel Dłucik
DPDomenico Puzzolo
Domenico Puzzolo
GSGiuseppe Santoro
Giuseppe Santoro
GAGiuseppe Acri
Giuseppe Acri
The aim of the present study was to propose the clinical efficacy of the different dentin matrix obtained from three devices (BonMaker, Tooth Transformer, and Smart Dentin Grinder) and to show thei...

Verified
Journal Article
Open access
PDF file
RDRobert Dłucik
Robert Dłucik
MFMarcel Firlej
Marcel Firlej
KBKatarzyna Bogus
Katarzyna Bogus
DDDaniel Dłucik
Daniel Dłucik
BOBogusława Ewa Orzechowska-Wylęgała
Bogusława Ewa Orzechowska-Wylęgała
Objective: This study aimed to compare the efficacy of Sticky Tooth (ST) derived from ground teeth and Sticky Bone (SB) based on equine bone and human allograft in maxillary bone defect regeneration through histological examination. Materials and Methods: Forty patients underwent maxillary alveolar ridge regeneration using four different biomaterials: Sticky Tooth processed with the BonMaker device (n = 10), Sticky Tooth prepared with the Smart Dentin Grinder (n = 10) Sticky Bone derived from an equine xenograft (n = 10), and Sticky Bone derived from human allografts (n = 10). CBCT imaging was performed preoperatively, post-regeneration, and during follow-up. Histological and quantitative statistical evaluation was conducted on biopsy samples obtained four months post-regeneration at the time of implant placement. Results: Successful alveolar ridge regeneration was achieved in all 40 patients. Histological analyses confirmed good integration between the biomaterials and bone tissue without signs of inflammation. Conclusion: Histological comparisons demonstrated that both ST and SB are effective biomaterials for bone regeneration. However, ST exhibited a faster bone healing process compared to xenograft and allograft SB.

Verified
Journal Article
Open access
PDF file
RDRobert Dłucik
Robert Dłucik
ASAlberto Scoglio
Alberto Scoglio
DPDomenico Puzzolo
Domenico Puzzolo
BTBarbara Testagrossa
Barbara Testagrossa
AAAngela Alibrandi
Angela Alibrandi
GAGiuseppe Acri
Giuseppe Acri
Dentin-derived biomaterials are hierarchical collagen–mineral composites increasingly used as bio-based scaffolds for bone regeneration. However, the effect of prolonged storage of extracted teeth on their physicochemical integrity remains unclear. This study evaluated the stability of dentin-derived biomaterials following long-term refrigerated storage (up to six years) using Raman spectroscopy. Extracted human teeth were processed using three preparation systems (BonMaker, Tooth Transformer, and Smart Dentin Grinder), and Raman-derived indices describing mineral and collagen structure were compared with freshly extracted controls. No time-dependent changes were observed in mineral crystallinity, carbonate substitution, or collagen-related parameters, indicating preservation of the collagen–mineral interface during storage. In contrast, the observed differences were primarily associated with processing pathways. Tooth Transformer and Smart Dentin Grinder exhibited Raman profiles closely resembling native dentin, whereas BonMaker showed reduced mineral content and altered mineral–matrix balance consistent with its demineralization protocol. These findings demonstrate that dentin behaves as a structurally stable hierarchical composite, reflecting intrinsic structural organization that limits physicochemical degradation over time. Long-term storage does not compromise dentin integrity, supporting its use as a reliable source of biomaterial for regenerative applications and future tooth banking strategies.

15 June 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
RDRobert Dłucik
Robert Dłucik
AMAnna Mertas
Anna Mertas
ZCZenon Czuba
Zenon Czuba
KZKarolina Ziaja
Karolina Ziaja
BOBogusława Ewa Orzechowska-Wylęgała
Bogusława Ewa Orzechowska-Wylęgała
Dentin derived from extracted human teeth has emerged as a promising autogenous biomaterial for bone regeneration. The growing interest in tooth-derived graft materials has also stimulated the development of tooth-banking concepts, in which extracted teeth are preserved for future regenerative applications. However, microbial contamination remains a potential concern, particularly when teeth are stored for prolonged periods before processing and clinical use. This in vitro study evaluated the microbiological status of dentin biomaterials prepared from human teeth stored under long-term refrigerated conditions and subsequently processed using three commercially available dentin-processing systems: BonMaker (BM), Tooth Transformer (TT), and Smart Dentin Grinder (SDG). A total of 72 extracted teeth collected between 2018 and 2025 were allocated to experimental groups and processed into 24 pooled dentin samples. Additionally, five freshly extracted teeth served as controls. Microbiological assessment was performed before and after processing using Schaedler Broth K3 culture media under aerobic and anaerobic conditions. Microorganisms isolated from positive cultures were identified using MALDI-TOF mass spectrometry. Baseline microbiological assessment detected bacterial contamination in 2 of 24 pooled dentin samples (8.3%) and in 4 of 5 control teeth (80.0%). The identified microorganisms included Staphylococcus epidermidis, Actinomyces viscosus, Streptococcus anginosus, Streptococcus mutans, and Staphylococcus hominis. No detectable microbial growth was observed in any sample following processing with BM, TT, or SDG, irrespective of storage duration, including teeth stored under refrigerated conditions for up to seven years. These findings suggest that the investigated dentin-processing protocols effectively eliminated microbiologically detectable contamination in dentin derived from long-term refrigerated human teeth. The results support the microbiological safety of dentin-derived biomaterials and provide preliminary microbiological evidence supporting the feasibility of future tooth-banking strategies. Further studies employing molecular microbiological techniques and larger sample sizes are required to confirm these findings.

Verified
Journal Article
Open access
PDF file
RDRobert Dłucik
Robert Dłucik
AMAnna Mertas
Anna Mertas
ZCZenon Czuba
Zenon Czuba
KZKarolina Ziaja
Karolina Ziaja
BOBogusława Ewa Orzechowska-Wylęgała
Bogusława Ewa Orzechowska-Wylęgała
Dentin derived from extracted human teeth has emerged as a promising autogenous biomaterial for bone regeneration owing to its structural and biological similarity to bone tissue. Growing clinical interest in dentin-derived graft materials has also stimulated the development of tooth-banking concepts, in which extracted teeth are preserved for future regenerative applications. However, microbiological contamination remains one of the principal concerns associated with long-term storage before clinical use. This in vitro study evaluated the microbiological status of dentin biomaterials prepared from human teeth stored under long-term refrigerated conditions (approximately 4 °C) and subsequently processed using three commercially available dentin-processing systems: BonMaker (BM), Tooth Transformer (TT), and Smart Dentin Grinder (SDG). A total of 72 extracted teeth collected between 2018 and 2025 were allocated to experimental groups and processed into 24 pooled dentin samples. Five freshly extracted teeth served as controls. Culture-based microbiological assessment was performed before and after dentin processing using Schaedler Broth K3 culture media under aerobic and anaerobic conditions. Microorganisms isolated from positive cultures were identified by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Baseline microbiological assessment detected bacterial contamination in 2 of 24 pooled dentin samples (8.3%) and in 4 of 5 control teeth (80.0%). The identified microorganisms included Staphylococcus epidermidis, Actinomyces viscosus, Streptococcus anginosus, Streptococcus mutans, and Staphylococcus hominis. No microbiologically detectable bacterial growth by culture-based methods was observed following processing with BM, TT, or SDG, irrespective of storage duration, including teeth preserved under refrigerated conditions for up to seven years. Within the limitations of this culture-based investigation, the evaluated dentin-processing protocols effectively eliminated microbiologically detectable cultivable bacterial contamination from long-term refrigerated dentin samples. These findings provide preliminary culture-based microbiological evidence supporting the feasibility of long-term refrigerated tooth preservation under the investigated storage conditions as one component of future tooth-banking research. Since culture-based microbiological methods do not detect viable but non-culturable microorganisms or other non-cultivable pathogens, the present findings should not be interpreted as evidence of complete sterility, overall biological safety, or the superiority of refrigerated storage over alternative preservation methods. Further studies employing molecular microbiological techniques together with biological and physicochemical analyses are required to comprehensively validate long-term tooth-banking protocols.