Ali Mohammad Ali Aljafery

Mr. Ali Mohammad Ali Aljafery

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2024 in Metals
Verified
Journal Article
Open access
PDF file
AAAli Mohammad Ali Aljafery
Ali Mohammad Ali Aljafery
Abdalbseet A FatallaAbdalbseet A Fatalla
Abdalbseet A Fatalla
Julfikar HaiderJulfikar Haider
Julfikar Haider
Objectives: Orthopedics and dentistry have widely utilized titanium alloys as biomaterials for dental implants, but limited research has been conducted on the fabrication of ceramic particle-reinforced Ti composites for further weight reductions. The current study compared titanium–titanium diboride metal composites (Ti-TiB2) with pure titanium (processed by powder metallurgy) in terms of toxicity, corrosion resistance, and wettability. Methods: First, cell lines of a primary dermal fibroblast normal human adult (HDFa) were used to test the cytocompatibility (in vitro) of the composite and pure Ti using an indirect contact approach. Corrosion testing was performed for the materials using electrochemical techniques such as potentiodynamic polarization in a simulated bodily fluid (SBF) in conjunction with a three-electrode electrochemical cell. The entire set of experimental tests was conducted according to the ASTM F746-04 protocol. The contact angles were measured during wettability testing in accordance with ASTM D7334-08. An X-ray diffractometer (XRD) was used to catalog every phase that was visible in the microstructure. A scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy (EDS) were used to determine the chemical composition. Results: The cytotoxicity tests revealed that there was no detectable level of toxicity, and there was no significant difference in the impact of either of the two materials on the viability of human fibroblasts. An increase in the corrosion resistance of the composite (0.036 ± 0.0001 mpy (millimeters per year)) demonstrated the development of a passive oxide coating. According to the findings, the composites showed a greater degree of hydrophilicity (contact angle 44.29° ± 0.28) than did the pure titanium (56.31° ± 0.47). Conclusions/Significance: The Ti-TiB2 composite showed no toxicity and better corrosion resistance and wettability than did pure Ti. The composite could be a suitable alternative to Ti for applications involving dental implants.

11 August 2020 in Nano Biomedicine and Engineering
Verified
Journal Article
Open access
OAOla Mohammed Aljubori
Ola Mohammed Aljubori
AAAli Mohammad Ali Aljafery
Ali Mohammad Ali Aljafery
RARaja'A Mahdi Al-Mussawi
Raja'A Mahdi Al-Mussawi

Verified
Journal Article
Open access
PDF file
AAAli Mohammad Ali Aljafery
Ali Mohammad Ali Aljafery
OAOla M. Al-Jubouri
Ola M. Al-Jubouri
ZWZena Wally
Zena Wally
RARajaa Mahdi Almusawi
Rajaa Mahdi Almusawi
NANoor H. Abdulrudha
Noor H. Abdulrudha
Julfikar HaiderJulfikar Haider
Julfikar Haider
One of the most widely used materials for the fabrication of prosthetic dental parts is acrylic resin. Its reasonable mechanical and physical properties make it a popular material for a wide range of dental applications. Recently, many attempts have been made to improve the mechanical and biological properties of this material, such as by adding fibres, nanoparticles, and nanotubes. The current study aimed to evaluate the effects of adding an antimicrobial agent, Ag-Zn zeolite, on the surface roughness and hardness of the denture base resins. Ag-Zn zeolite particles were chemically prepared and added at different concentrations (0.50 wt.% and 0.75 wt.%) to the heat cure (HC) and cold cure (CC) acrylic resins. Zeolite particles were characterized and confirmed using X-ray diffraction (XRD) and Energy-Dispersive X-ray Spectroscopy (EDX) attached with a Scanning Electron Microscope (SEM). Sixty disk shape specimens (40 mm diameter and 2 mm thickness) were fabricated from the HC and CC resins with and without the zeolite. All the specimens were divided into two main groups based on the acrylic resins, then each was subdivided into three groups (n = 10) according to the concentration of the Ag-Zn zeolite. A surface roughness and a hardness tester were used to measure the surface finish and hardness of the specimens. The analysed data showed that the surface roughness values significantly decreased when 0.50 wt.% and 0.75 wt.% zeolite were incorporated in the HC resin specimens compared to the control group. However, this reduction was not significant in the case of CC resin, while the surface hardness was significantly improved after incorporating 0.50 wt.% and 0.75 wt.% zeolite for both the CC and HC resins. Incorporating Ag-Zn zeolite with acrylic resin materials could be beneficial for improving their surface finish and resistance to surface damage as defined by the higher hardness.

1 March 2018 in Nano Biomedicine and Engineering
Verified
Journal Article
Open access
AAAli Mohammad Ali Aljafery
Ali Mohammad Ali Aljafery

24 September 2024 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
AAAli Mohammad Ali Aljafery
Ali Mohammad Ali Aljafery
Abdalbseet A FatallaAbdalbseet A Fatalla
Abdalbseet A Fatalla
Julfikar HaiderJulfikar Haider
Julfikar Haider

25 August 2023 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
AAAli Mohammad Ali Aljafery
Ali Mohammad Ali Aljafery
Abdalbseet A FatallaAbdalbseet A Fatalla
Abdalbseet A Fatalla
Julfikar HaiderJulfikar Haider
Julfikar Haider
Due to the advantages over other metallic materials, such as superior corrosion resistance, excellent biocompatibility, and favorable mechanical properties, titanium, its alloys and related composites, are frequently utilized in biomedical applications, particularly in orthopedics and dentistry. This work focuses on developing novel titanium-titanium diboride (TiB2; ceramic material) composites for dental implants where TiB2 additions were estimated to be 9 wt.%. In a steel mold, Ti-TiB2 composites were fabricated using a powder metallurgy technique and sintered for five hours at 1200 °C. Microstructural and chemical properties were analyzed by energy dispersive X-ray spectroscopy (EDX), scanning electron microscopy (SEM), and X-ray diffraction (XRD) to evaluate the impact of the TiB2 ceramic addition. Compressive strength, Brinell hardness, porosity, and density, among other mechanical and physical properties, were also measured and characterized. It has been found that adding TiB2 to Ti increases its porosity (35.53%), compressive strength (203.04 MPa), and surface hardness (296.3 kg/mm2) but decreases its density (3.79 gm/cm3). The lightweight and strong composite could be suitable for dental implant applications.