This article proposes a passivity method synthesized by an adaptive neuro fuzzy inference system (ANFIS) to control a grid-tied nine-level packed E-cell (PEC9) inverter. PEC9 is an optimized components count of single-phase, single-dc-source, compact multilevel converter with an appealing feature of dc capacitors horizontal extension. Indeed, PEC9 forms a single auxiliary dc-bus to actively balance its voltages so as grid-tied controller would not be charge of capacitors voltages balancing. Hence, the proposed intelligent-based passivity control (IPC) is designed using only the dynamical model of the PEC9 inverter current. The zero dynamics of state variable errors are obtained and a damping coefficient matrix is presented to theoretically analyze the convergence rate of PEC9 inverter currents under the proposed control functions. In addition, various operating margins of damping coefficients are inquired. So, using the margins, a trained ANFIS as an online estimator tracks the damping injections. It precisely regulates the damping coefficients in unstable conditions; thus, the excellent PEC9 inverter operation is guaranteed. Experiments and simulations validate high reliable performance of the proposed IPC technique under various grid-tied operational conditions.
27 October 2021 in IEEE Transactions on Industrial Electronics
In this article, we propose a sliding fractional-order (FO) control strategy to provide robustness feature for integrating a multilevel converter into the power grid under the system parameter uncertainties, nonlinear load alterations, and grid voltage sag. All dynamics achieved from the input capacitors and output inductances of the multilevel converter are utilized to design the proposed sliding fractional surfaces (SFSs) such that a robust operation of the grid-tied converter-based system is achieved. Then, an SFS-based Lyapunov function is built to assess the proposed controller stability. A thorough analysis of the Lyapunov function is carried out for distinguishing suitable boundaries of the controller coefficients when the error components of the system state variables are changed, accordingly. Using the derivative of Lyapunov function and SFS, a comprehensive evaluation is executed to detail the regulation procedure for the robustness and fractional PI controller coefficients. Finally, a closed-loop system using the converter current dynamics aims to discern the differences between different values of FO. Experimental tests using dSPACE-1202 along with MATLAB/Simulink simulations are employed to verify the effectiveness of the proposed control technique for providing proper harmonic compensation, enhanced power quality, unity power factor, voltage sag tolerance, and very low total harmonic distortion grid current.
This paper proposes a robust control technique based on Differential Flatness Theory (DFT) for a grid-tied Distributed Generation (DG) to mitigate several uncertainties while controlling the DG for its main functions. A recently introduced structure named Dumbbell Type (D-type) Switched-Capacitor Multilevel Converter (SC-MLC) with a single DC source, utilizing only ten switches with no further series diodes, is employed as an interfacing converter. The DFT enriched by the Lyapunov criterion is developed for the SC-MLC to guarantee both the stable performance of the proposed DG-based supply system and the robustness feature against any unwanted uncertainties. The control inputs of the D-type converter are initially shaped using the reactive and active power-based flat outputs without the observance of stability issues. To attain the proposed robust control inputs, a Lyapunov function is properly defined and engaged in providing the global asymptotic stability for the grid-tied multilevel converter by means of the proportional and integral errors of the flat outputs under the model uncertainties and parameter change. Lyapunov coefficients are subsequently assessed through their related active and reactive power errors. Both simulation and experimental results are employed to verify the validity of the proposed controller. The proposed method provides advantages such as robustness, accurate power sharing ability, and direct control of active and reactive power flows.
This paper proposes a hierarchical multi-stage approach based on a distributed level phasor measurement unit (µPMU) at local controllers and a phasor data concentrator (PDC) at the central control unit to restore system voltage when it exceeds the limits recommended by the IEEE 1547-2018 standard. The proposed algorithm does not need an accurate system model or employ optimization solutions. Therefore, it has less implementation complexity and would be popular among distribution network service providers (DNSPs) and distribution network operators (DNOs) as it does not suffer from cost and computational complexity limitations. A PMU-PDC-based communication platform has been developed as a more efficient alternative to the supervisory control and data acquisition (SCADA) system, and provides superior characteristics, including a higher sample rate, higher data resolutions, and faster communication. The proposed coordinated algorithm aims to postpone power generation curtailment in distributed energy resources (DERs) with overvoltage problems (local DERs) by incorporating all the DERs that are not subjected to voltage violation (remote DERs) by absorbing their maximum reactive power capacity. If the system voltage has not recovered after absorbing all of the reactive power capacity of all the DERs, a reduced active power curtailment proposed by the algorithm is then applied to the system to control the voltage. The proposed strategy has been simulated in MATLAB and applied to IEEE 13-bus and IEEE 33-bus radial distribution benchmark systems to validate the performance of the system, in terms of its ability to coordinate voltage control and the accuracy of the PMU-PDC-based communication interface.