Bhavna Gupta

Ms. Bhavna Gupta

Neuroscience, Michigan State University, East Lansing, Michigan, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
BGBhavna Gupta
Bhavna Gupta
MPMason Perillo
Mason Perillo
JSJames Siegenthaler
James Siegenthaler
ICIsabelle Christensen
Isabelle Christensen
MWMatthew P. Welch
Matthew P. Welch
EPErin Purcell
Erin Purcell
Neurotransmitter release is important to study in order to better understand neurological diseases and treatment approaches. Serotonin is a neurotransmitter known to play key roles in the etiology of neuropsychiatric disorders. Fast-scan cyclic voltammetry (FSCV) has enabled the detection of neurochemicals, including serotonin, on a sub-second timescale via the well-established carbon fiber microelectrode (CFME). However, poor chronic stability and biofouling, i.e., the adsorption of interferent proteins to the electrode surface upon implantation, pose challenges in the natural physiological environment. We have recently developed a uniquely designed, freestanding, all-diamond boron-doped diamond microelectrode (BDDME) for electrochemical measurements. Key potential advantages of the device include customizable electrode site layouts, a wider working potential window, improved stability, and resistance to biofouling. Here, we present a first report on the electrochemical behavior of the BDDME in comparison with CFME by investigating in vitro serotonin (5-HT) responses with varying FSCV waveform parameters and biofouling conditions. While the CFME delivered lower limits of detection, we also found that BDDMEs showed more sustained 5-HT responses to increasing or changing FSCV waveform-switching potential and frequency, as well as to higher analyte concentrations. Biofouling-induced current reductions were significantly less pronounced at the BDDME when using a “Jackson” waveform compared to CFMEs. These findings are important steps towards the development and optimization of the BDDME as a chronically implanted biosensor for in vivo neurotransmitter detection.

19 July 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
MPMason Perillo
Mason Perillo
BGBhavna Gupta
Bhavna Gupta
JSJames Siegenthaler
James Siegenthaler
ICIsabelle Christensen
Isabelle Christensen
BKBrandon Kepros
Brandon Kepros
EPErin Purcell
Erin Purcell
Fast-scan cyclic voltammetry (FSCV) is an electrochemical sensing technique that can be used for neurochemical sensing with high spatiotemporal resolution. Carbon fiber microelectrodes (CFMEs) are traditionally used as FSCV sensors. However, CFMEs are prone to electrochemical fouling caused by oxidative byproducts of repeated serotonin (5-HT) exposure, which makes them less suitable as chronic 5-HT sensors. Our team is developing a boron-doped diamond microelectrode (BDDME) that has previously been shown to be relatively resistant to fouling caused by protein adsorption (biofouling). We sought to determine if this BDDME exhibits resistance to electrochemical fouling, which we explored on electrodes fabricated with either femtosecond laser cutting or physical cleaving. We recorded the oxidation current response after 25 repeated injections of 5-HT in a flow-injection cell and compared the current drop from the first with the last injection. The 5-HT responses were compared with dopamine (DA), a neurochemical that is known to produce minimal fouling oxidative byproducts and has a stable repeated response. Physical cleaving of the BDDME yielded a reduction in fouling due to 5-HT compared with the CFME and the femtosecond laser cut BDDME. However, the femtosecond laser cut BDDME exhibited a large increase in sensitivity over the cleaved BDDME. An extended stability analysis was conducted for all device types following 5-HT fouling tests. This analysis demonstrated an improvement in the long-term stability of boron-doped diamond over CFMEs, as well as a diminishing sensitivity of the laser-cut BDDME over time. This work reports the electrochemical fouling performance of the BDDME when it is repeatedly exposed to DA or 5-HT, which informs the development of a chronic, diamond-based electrochemical sensor for long-term neurotransmitter measurements in vivo.

15 June 2026 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
BGBhavna Gupta
Bhavna Gupta
ACAnirban Chakraborty
Anirban Chakraborty
ASAkash Saxena
Akash Saxena
MMMichael G. Moore
Michael G. Moore
QWQuentin A. Whitsitt
Quentin A. Whitsitt
EPErin Purcell
Erin Purcell
The foreign body reaction to implanted electrodes in the brain has long been recognized as a major challenge impacting the performance and reliability of indwelling neurotechnologies. Spatially resolved transcriptomic approaches have enabled high-resolution mapping of cellular and molecular dynamics at the device-tissue interface, yielding novel insight into both acute and chronic tissue responses. Recent whole-transcriptome profiling methods generate exceptionally dense gene expression datasets from individual samples, offering unprecedented resolution and analytical power. Yet, limited studies have explored aggregated results from larger datasets and sample-to-sample variation within an implanted cohort using such techniques due to high costs and complicated downstream analyses. In this work, we provide a comprehensive report of spatial transcriptomics data collected from an expanded cohort of rats ( n = 14 rats) implanted with silicon microelectrode arrays in the motor cortices for 1 week (acute) and 6 weeks (chronic). This larger dataset enabled us to explore the variation in results across samples, assess outliers, and examine potential batch effects. We employed differential expression analysis to identify top differentially expressed genes (DEGs) in spatially defined regions at the device-tissue interface to reveal novel biomarkers in the aggregated dataset. We assessed sample-to-sample variabilities, and applied a factorization strategy to identify prominent cell-type contributors of the top DEGs. Using network-based co-expression analysis, we identified gene modules, hub genes, and central regulatory processes governing the device-tissue interface. Our results show: (a) greater variation of top DEGs across samples at the 1-week time point with notable microglial and astroglial cell-type contributors, (b) lower variation of top DEGs across samples and a shift to prominent astroglial cell-type contributors at the 6-week time point, and (c) novel biomarkers that suggest major macrophage- and microglial mediated processes and homeostasis events at the 1-week time point, and greater tissue remodeling, apoptotic and synaptic changes at the 6-week time point. These findings support previous ideas on the evolving tissue response to implanted devices, and present novel details on biomarkers, biological processes and sample variation. Additionally, this study provides a framework for assessing larger datasets employing high-dimensional spatial transcriptomics and highlight key considerations related to across-sample variability and batch effects.

1 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MPMason Perillo
Mason Perillo
BGBhavna Gupta
Bhavna Gupta
JSJames Siegenthaler
James Siegenthaler
ICIsabelle Christensen
Isabelle Christensen
BKBrandon Kepros
Brandon Kepros
EPErin Purcell
Erin Purcell
Fast-scan cyclic voltammetry (FSCV) is an electrochemical sensing technique that can be used for neurochemical sensing with high spatiotemporal resolution. Carbon fiber microelectrodes (CFMEs) are traditionally used as FSCV sensors. However, CFMEs are prone to electrochemical fouling caused by oxidative byproducts of repeated serotonin (5-HT) exposure, which makes them less suitable as a chronic 5-HT sensor. Our team is developing a boron-doped diamond microelectrode (BDDME) that has previously been shown to be relatively resistant to fouling caused by protein adsorption (biofouling). We sought to determine if the BDDME exhibits resistance to electrochemical fouling, which we explored on electrodes fabricated with either femtosecond laser cutting or physical cleaving. We recorded the oxidation current response after 25 repeated injections of 5-HT in a flow-injection-cell and compared the current drop from the first to the last injection. The 5-HT responses were compared to dopamine (DA), a neurochemical that is known to produce minimal fouling oxidative byproducts and have a stable repeated response. Physical cleaving of the BDDME yielded a reduction in fouling due to 5-HT compared to the CFME and the femtosecond laser cut BDDME. However, the femtosecond laser cut BDDME exhibited a large increase in sensitivity over the cleaved BDDME. An extended stability analysis was conducted for all device types following 5-HT fouling tests. This analysis demonstrated an improvement in the long-term stability of boron doped diamond over CFMEs, as well as a diminishing sensitivity of the laser cut BDDME over time. This work reports the electrochemical fouling performance of the BDDME when it is repeatedly exposed to DA or 5-HT, which informs the development of a chronic, diamond-based electrochemical sensor for long-term neurotransmitter measurements in vivo.