James Siegenthaler

Dr. James Siegenthaler

Fraunhofer USA Center Midwest
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
EPErin Purcell
Erin Purcell
MBMichael F. Becker
Michael F. Becker
YGYue Guo
Yue Guo
SHSeth Hara
Seth Hara
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
WLWen Li
Wen Li
Carbon-based electrodes combined with fast-scan cyclic voltammetry (FSCV) enable neurochemical sensing with high spatiotemporal resolution and sensitivity. While their attractive electrochemical and conductive properties have established a long history of use in the detection of neurotransmitters both in vitro and in vivo, carbon fiber microelectrodes (CFMEs) also have limitations in their fabrication, flexibility, and chronic stability. Diamond is a form of carbon with a more rigid bonding structure (sp3-hybridized) which can become conductive when boron-doped. Boron-doped diamond (BDD) is characterized by an extremely wide potential window, low background current, and good biocompatibility. Additionally, methods for processing and patterning diamond allow for high-throughput batch fabrication and customization of electrode arrays with unique architectures. While tradeoffs in sensitivity can undermine the advantages of BDD as a neurochemical sensor, there are numerous untapped opportunities to further improve performance, including anodic pretreatment, or optimization of the FSCV waveform, instrumentation, sp2/sp3 character, doping, surface characteristics, and signal processing. Here, we review the state-of-the-art in diamond electrodes for neurochemical sensing and discuss potential opportunities for future advancements of the technology. We highlight our team’s progress with the development of an all-diamond fiber ultramicroelectrode as a novel approach to advance the performance and applications of diamond-based neurochemical sensors.

26 September 2022 in EcoMat
Verified
Journal Article
Open access
HXHongyuan Xu
Hongyuan Xu
ZKZhao Kong
Zhao Kong
JSJames Siegenthaler
James Siegenthaler
BZBocong Zheng
Bocong Zheng
YTYihong Tong
Yihong Tong
Hong JinHong Jin
Hong Jin
With the advantages of superior energy density, lithium‐sulfur batteries (LSBs) have been considered as one of the promising next‐generation batteries. However, some key issues, such as the shuttle effect of the intermediate lithium polysulfides, poor conductivity of the sulfur, Li2S and Li2S2, and huge volume variation during charge/discharge process, have hindered its development. In this respect, a variety of nanomaterials have been used to overcome the above‐mentioned defects. Among them, two‐dimensional (2D) nanomaterials present unique merits for enhancing the electrochemical performance of LSBs owing to their unique structural properties. Nevertheless, the variation of 2D nanomaterials used in LSBs is rarely discussed. Herein, this work systematically reviews the state‐of‐the‐art progress in LSB cathode development through 2D materials such as graphene, MXenes, 2D compounds, and so forth. With a comprehensive analysis, the challenges and perspectives for 2D nanomaterials in LSBs application are proposed and discussed. image

14 May 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
Pramod Kumar GuptaPramod Kumar Gupta
Pramod Kumar Gupta
JSJames Siegenthaler
James Siegenthaler
Nanomaterial advancements have heralded a new era in electrochemical sensing by enabling the precise modification of boron-doped diamond (BDD) electrodes. This review investigates recent remarkable advances, challenges, and potential future directions of nanomaterial-modified BDD electrodes for biosensing applications, emphasizing their game-changing potential. This review begins by investigating the intrinsic properties of boron-doped diamond electrodes, emphasizing their inherent advantages in electrochemical biosensing. Following that, it embarks on an illuminating journey through the spectrum of nanomaterials that have revolutionized these electrodes. These materials include carbon-based nanomaterials, metal and metal oxide nanostructures, their combinations, patterned nanostructures on BDDs, and other nanomaterials, each with unique properties that can be used to tailor BDD electrodes to specific applications. Throughout this article, we explain how these nanomaterials improve BDD electrodes, from accelerated electron transfer kinetics to increased surface area and sensitivity, promising unprecedented performance. Beyond experimentation, it investigates the challenges—stability, reproducibility, and scalability—associated with the use of nanomaterials in BDD electrode modifications, as well as the ecological and economic implications. Furthermore, the future prospects of nanomaterial-modified BDD electrodes hold the key to addressing pressing contemporary research challenges.

25 May 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
BGBhavna Gupta
Bhavna Gupta
MPMason Perillo
Mason Perillo
JSJames Siegenthaler
James Siegenthaler
ICIsabelle Christensen
Isabelle Christensen
MWMatthew P. Welch
Matthew P. Welch
EPErin Purcell
Erin Purcell
Neurotransmitter release is important to study in order to better understand neurological diseases and treatment approaches. Serotonin is a neurotransmitter known to play key roles in the etiology of neuropsychiatric disorders. Fast-scan cyclic voltammetry (FSCV) has enabled the detection of neurochemicals, including serotonin, on a sub-second timescale via the well-established carbon fiber microelectrode (CFME). However, poor chronic stability and biofouling, i.e., the adsorption of interferent proteins to the electrode surface upon implantation, pose challenges in the natural physiological environment. We have recently developed a uniquely designed, freestanding, all-diamond boron-doped diamond microelectrode (BDDME) for electrochemical measurements. Key potential advantages of the device include customizable electrode site layouts, a wider working potential window, improved stability, and resistance to biofouling. Here, we present a first report on the electrochemical behavior of the BDDME in comparison with CFME by investigating in vitro serotonin (5-HT) responses with varying FSCV waveform parameters and biofouling conditions. While the CFME delivered lower limits of detection, we also found that BDDMEs showed more sustained 5-HT responses to increasing or changing FSCV waveform-switching potential and frequency, as well as to higher analyte concentrations. Biofouling-induced current reductions were significantly less pronounced at the BDDME when using a “Jackson” waveform compared to CFMEs. These findings are important steps towards the development and optimization of the BDDME as a chronically implanted biosensor for in vivo neurotransmitter detection.

17 May 2024 in Advanced Functional Materials
Verified
Journal Article
Open access
MDMitchell Delemeester
Mitchell Delemeester
KPKendell M. Pawelec
Kendell M. Pawelec
JHJeremy M.L. Hix
Jeremy M.L. Hix
JSJames Siegenthaler
James Siegenthaler
MLMicah Lissy
Micah Lissy
ESErik M. Shapiro
Erik M. Shapiro
3D‐printed biomaterial implants are revolutionizing personalized medicine for tissue repair, especially in orthopedics. In this study, a radiopaque bismuth oxide (Bi2O3) doped polycaprolactone (PCL) composite is developed and implemented to enable the use of diagnostic X‐ray technologies, especially spectral photon counting X‐ray computed tomography (SPCCT), for comprehensive tissue engineering scaffold (TES) monitoring. PCL filament with homogeneous Bi2O3 nanoparticle (NP) dispersion (0.8 to 11.7 wt%) is first fabricated. TES are then 3D printed with the composite filament, optimizing printing parameters for small features and severely overhung geometries. These composite TES are characterized via micro‐computed tomography (µCT), tensile testing, and a cytocompatibility study, with 2 wt% Bi2O3 NPs providing improved tensile properties, equivalent cytocompatibility to neat PCL, and excellent radiographic distinguishability. Radiographic performance is validated in situ by imaging 4 and 7 wt% Bi2O3 doped PCL TES in a mouse model with µCT, showing excellent agreement with in vitro measurements. Subsequently, CT image‐derived swine menisci are 3D printed with composite filament and re‐implanted in corresponding swine legs ex vivo. Re‐imaging the swine legs via clinical CT allows facile identification of device location and alignment. Finally, the emergent technology of SPCCT unambiguously distinguishes the implanted meniscus in situ via color K‐edge imaging.

8 January 2025 in Advanced Materials Technologies
Verified
Journal Article
Open access
MPMason Perillo
Mason Perillo
BGBhavna Gupta
Bhavna Gupta
ASAkash Saxena
Akash Saxena
AVAlexandra P. Veltri
Alexandra P. Veltri
WLWen Li
Wen Li
EPErin Purcell
Erin Purcell
Fast‐scan cyclic voltammetry (FSCV) is a popular approach for real‐time neurochemical sensing. Using a carbon‐fiber microelectrode (CFME), sensitive neurochemical sensing can be achieved in the acute setting with sub‐second resolution for monoamine neurotransmitters. However, to study neuropsychiatric conditions and neurological functions, it is often of interest to perform longitudinal monitoring of neurotransmitters over chronic timepoints. Despite notable successes, there remains substantial room for improvement in chronic neurochemical sensing performance. Electrode fouling and cellular encapsulation that can occur following surgical implantation can lead to diminished sensor performance over time. Additionally, working and reference electrodes can suffer from etching and polarization that can hinder their longevity and stability. Here, this work reviews current challenges facing chronic neurochemical sensors and discusses state‐of‐the‐art advancements in electrode material and device design choices. This work covers how the biological environment can negatively affect sensing performance and how device design can mitigate these effects. This work also provides examples of state‐of‐the‐art electrode technologies that have been developed to improve chronic neurochemical sensing. Improvements in FSCV as a tool for chronic neurotransmitter sensing will open new opportunities to study neurodegenerative and neuropsychiatric diseases, develop feedback systems for neuromodulation, and explore the neurochemical underpinnings of normal brain function and behavior.