Erin Purcell

Dr. Erin Purcell


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2015 in Tissue Engineering Part B: Reviews
Verified
Journal Article
Closed access
CTCort H. Thompson
Cort H. Thompson
MZMarissa J. Zoratti
Marissa J. Zoratti
NLNicholas B. Langhals
Nicholas B. Langhals
EPErin Purcell
Erin Purcell
Neural prostheses are electrode arrays implanted in the nervous system that record or stimulate electrical activity in neurons. Rapid growth in the use of neural prostheses in research and clinical applications has occurred in recent years, but instability and poor patency in the tissue–electrode interface undermines the longevity and performance of these devices. The application of tissue engineering strategies to the device interface is a promising approach to improve connectivity and communication between implanted electrodes and local neurons, and several research groups have developed new and innovative modifications to neural prostheses with the goal of seamless device–tissue integration. These approaches can be broadly categorized based on the strategy used to maintain and regenerate neurons at the device interface: (1) redesign of the prosthesis architecture to include finer-scale geometries and/or provide topographical cues to guide regenerating neural outgrowth, (2) incorporation of material coatings and bioactive molecules on the prosthesis to improve neuronal growth, viability, and adhesion, and (3) inclusion of cellular grafts to replenish the local neuron population or provide a target site for reinnervation (biohybrid devices). In addition to stabilizing the contact between neurons and electrodes, the potential to selectively interface specific subpopulations of neurons with individual electrode sites is a key advantage of regenerative interfaces. In this study, we review the development of regenerative interfaces for applications in both the peripheral and central nervous system. Current and future development of regenerative interfaces has the potential to improve the stability and selectivity of neural prostheses, improving the patency and resolution of information transfer between neurons and implanted electrodes.

27 April 2021 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
CTCort H Thompson
Cort H Thompson
ASAkash Saxena
Akash Saxena
NHNicholas Heelan
Nicholas Heelan
JSJoseph Salatino
Joseph Salatino
EPErin Purcell
Erin Purcell
Objective. Intracortical brain interfaces are an ever evolving technology with growing potential for clinical and research applications. The chronic tissue response to these devices traditionally has been characterized by glial scarring, inflammation, oxidative stress, neuronal loss, and blood-brain barrier disruptions. The full complexity of the tissue response to implanted devices is still under investigation. Approach. In this study, we have utilized RNA-sequencing to identify the spatiotemporal gene expression patterns in interfacial (within 100 µm) and distal (500 µm from implant) brain tissue around implanted silicon microelectrode arrays. Naïve, unimplanted tissue served as a control. Main results. The data revealed significant overall differential expression (DE) in contrasts comparing interfacial tissue vs naïve (157 DE genes), interfacial vs distal (94 DE genes), and distal vs naïve tissues (21 DE genes). Our results captured previously characterized mechanisms of the foreign body response, such as astroglial encapsulation, as well as novel mechanisms which have not yet been characterized in the context of indwelling neurotechnologies. In particular, we have observed perturbations in multiple neuron-associated genes which potentially impact the intrinsic function and structure of neurons at the device interface. In addition to neuron-associated genes, the results presented in this study identified significant DE in genes which are associated with oligodendrocyte, microglia, and astrocyte involvement in the chronic tissue response. Significance. The results of this study increase the fundamental understanding of the complexity of tissue response in the brain and provide an expanded toolkit for future investigation into the bio-integration of implanted electronics with tissues in the central nervous system.

12 March 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
CTCort H Thompson
Cort H Thompson
TRTi’aIr E Riggins
Ti’aIr E Riggins
PPParas R Patel
Paras R Patel
CCCynthia A Chestek
Cynthia A Chestek
WLWen Li
Wen Li
EPErin Purcell
Erin Purcell
Innovation in electrode design has produced a myriad of new and creative strategies for interfacing the nervous system with softer, less invasive, more broadly distributed sites with high spatial resolution. However, despite rapid growth in the use of implanted electrode arrays in research and clinical applications, there are no broadly accepted guiding principles for the design of biocompatible chronic recording interfaces in the central nervous system (CNS). Studies suggest that the architecture and flexibility of devices play important roles in determining effective tissue integration: device feature dimensions (varying from ‘sub’- to ‘supra’-cellular scales, 100 µ m), Young’s modulus, and bending modulus have all been identified as key features of design. However, critical knowledge gaps remain in the field with respect to the underlying motivation for these designs: (1) a systematic study of the relationship between device design features (materials, architecture, flexibility), biointegration, and signal quality needs to be performed, including controls for interaction effects between design features, (2) benchmarks for success need to be determined (biological integration, recording performance, longevity, stability), and (3) user results, particularly those that champion a specific design or electrode modification, need to be replicated across laboratories. Finally, the ancillary effects of factors such as tethering, site impedance and insertion method need to be considered. Here, we briefly review observations to-date of device design effects on tissue integration and performance, and then highlight the need for comprehensive and systematic testing of these effects moving forward.

5 October 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
HLHaitao Li
Haitao Li
SPSina Parsnejad
Sina Parsnejad
EAEhsan Ashoori
Ehsan Ashoori
CTCort Thompson
Cort Thompson
EPErin Purcell
Erin Purcell
AMAndrew J. Mason
Andrew J. Mason
High-density on-chip electrochemical biosensor arrays are advancing toward a crucial role in health monitoring and development of new medicines and medical treatments. Nanopore and ion channel based sensors especially have great potential but present demanding resolution/speed/power/area requirements on instrumentation circuits. This paper presents a pixel-level current readout circuit and new group-cluster architecture to address the circuit challenges in high-performance biosensor arrays. Fabricated in 0.5 μm CMOS, this electrochemical voltammetry circuit achieves 7.2 pArms noise in an 11.5-kHz bandwidth and only consumes 21-μ W power and 0.06 mm 2 area per readout channel. Cyclic voltammetry experiments in a potassium ferricyanide solution and patch-clamp whole-cell experiments were performed to validate the circuit's feasibility for electrochemical biosensor applications.

26 January 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
EPErin Purcell
Erin Purcell
MBMichael F. Becker
Michael F. Becker
YGYue Guo
Yue Guo
SHSeth Hara
Seth Hara
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
WLWen Li
Wen Li
Carbon-based electrodes combined with fast-scan cyclic voltammetry (FSCV) enable neurochemical sensing with high spatiotemporal resolution and sensitivity. While their attractive electrochemical and conductive properties have established a long history of use in the detection of neurotransmitters both in vitro and in vivo, carbon fiber microelectrodes (CFMEs) also have limitations in their fabrication, flexibility, and chronic stability. Diamond is a form of carbon with a more rigid bonding structure (sp3-hybridized) which can become conductive when boron-doped. Boron-doped diamond (BDD) is characterized by an extremely wide potential window, low background current, and good biocompatibility. Additionally, methods for processing and patterning diamond allow for high-throughput batch fabrication and customization of electrode arrays with unique architectures. While tradeoffs in sensitivity can undermine the advantages of BDD as a neurochemical sensor, there are numerous untapped opportunities to further improve performance, including anodic pretreatment, or optimization of the FSCV waveform, instrumentation, sp2/sp3 character, doping, surface characteristics, and signal processing. Here, we review the state-of-the-art in diamond electrodes for neurochemical sensing and discuss potential opportunities for future advancements of the technology. We highlight our team’s progress with the development of an all-diamond fiber ultramicroelectrode as a novel approach to advance the performance and applications of diamond-based neurochemical sensors.

17 April 2024 in Accounts of Chemical Research
Verified
Journal Article
Open access
BGBhavna Gupta
Bhavna Gupta
ASAkash Saxena
Akash Saxena
MPMason L. Perillo
Mason L. Perillo
LWLauren C. Wade-Kleyn
Lauren C. Wade-Kleyn
CTCort H. Thompson
Cort H. Thompson
EPErin Purcell
Erin Purcell
ConspectusImplantable neurotechnology enables monitoring and stimulating of the brain signals responsible for performing cognitive, motor, and sensory tasks. Electrode arrays implanted in the brain are increasingly used in the clinic to treat a variety of sources of neurological diseases and injuries. However, the implantation of a foreign body typically initiates a tissue response characterized by physical disruption of vasculature and the neuropil as well as the initiation of inflammation and the induction of reactive glial states. Likewise, electrical stimulation can induce damage to the surrounding tissue depending on the intensity and waveform parameters of the applied stimulus. These phenomena, in turn, are likely influenced by the surface chemistry and characteristics of the materials employed, but further information is needed to effectively link the biological responses observed to specific aspects of device design. In order to inform improved design of implantable neurotechnology, we are investigating the basic science principles governing device-tissue integration. We are employing multiple techniques to characterize the structural, functional, and genetic changes that occur in the cells surrounding implanted electrodes. First, we have developed a new "device-in-slice" technique to capture chronically implanted electrodes within thick slices of live rat brain tissue for interrogation with single-cell electrophysiology and two-photon imaging techniques. Our data revealed several new observations of tissue remodeling surrounding devices: (a) there was significant disruption of dendritic arbors in neurons near implants, where losses were driven asymmetrically on the implant-facing side. (b) There was a significant loss of dendritic spine densities in neurons near implants, with a shift toward more immature (nonfunctional) morphologies. (c) There was a reduction in excitatory neurotransmission surrounding implants, as evidenced by a reduction in the frequency of excitatory postsynaptic currents (EPSCs). Lastly, (d) there were changes in the electrophysiological underpinnings of neuronal spiking regularity. In parallel, we initiated new studies to explore changes in gene expression surrounding devices through spatial transcriptomics, which we applied to both recording and stimulating arrays. We found that (a) device implantation is associated with the induction of hundreds of genes associated with neuroinflammation, glial reactivity, oligodendrocyte function, and cellular metabolism and (b) electrical stimulation induces gene expression associated with damage or plasticity in a manner dependent upon the intensity of the applied stimulus. We are currently developing computational analysis tools to distill biomarkers of device-tissue interactions from large transcriptomics data sets. These results improve the current understanding of the biological response to electrodes implanted in the brain while producing new biomarkers for benchmarking the effects of novel electrode designs on responses. As the next generation of neurotechnology is developed, it will be increasingly important to understand the influence of novel materials, surface chemistries, and implant architectures on device performance as well as the relationship with the induction of specific cellular signaling pathways.