Jason David

Mr. Jason David

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020
Verified
Conference Paper
Closed access
DDDilini Darmawardana
Dilini Darmawardana
JDJason David
Jason David
SPSarath Perera
Sarath Perera
DRDuane Robinson
Duane Robinson
JMJan Meyer
Jan Meyer
UJUpuli Jayatunga
Upuli Jayatunga
High frequency (HF) emissions in the range of 2-150 kHz (or Supraharmonics) originating due to the internal switching operation of power electronic devices are an emerging power quality concern in electricity distribution networks. Among many HF sources, electric vehicle (EV) chargers play an important role. However, the present understanding related to the behaviour of HF emissions due to EV charging is limited. Therefore, in this paper, HF emissions caused by charging of two EVs using their on-board chargers and a DC fast charging station are investigated. The findings of the study are expected to improve understanding related to HF emissions from EVs and provide important insights into modelling of EV chargers for HF studies.

28 October 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
WXWilsun Xu
Wilsun Xu
RLRoberto Langella
Roberto Langella
Antonio BracaleAntonio Bracale
Antonio Bracale
YSYuanyuan Sun
Yuanyuan Sun
KLKuo Lung Lian
Kuo Lung Lian
JDJason David
Jason David
Inverter-based resources (IBRs) are a new type of generators entering power systems. Industries are concerned about the harmonic impact caused by IBR plants. How to model IBRs for harmonic studies has, therefore, become an important topic. This industry application-oriented tutorial paper presents a comprehensive review and analysis of the harmonic behaviors of IBR units, covering their harmonic characteristics, advanced and practical harmonic models, methods for model parameter determination and more. Lab test results on a physical IBR unit are presented to substantiate the findings. It is hoped this paper will clarify the confusion between the harmonic models of VSC (voltage source converter) based IBR units versus LCC (line commutated converter) based loads. Furthermore, a comparison between IBRs and synchronous generators reveals many similarities in their harmonic behaviors.

29 May 2024 in Energies
Verified
Journal Article
Open access
PDF file
Kasun PeirisKasun Peiris
Kasun Peiris
SESean Elphick
Sean Elphick
JDJason David
Jason David
Duane RobinsonDuane Robinson
Duane Robinson
In recent years, integration of solar photovoltaic (PV) systems into distribution networks has been increasing rapidly, as it has become the most promising renewable energy source (RES) in the transition of power generation from centralised to decentralised systems. With the power electronic (PE) interfaces that use high-frequency internal switching, all renewable energy sources are considered to be harmonic emitters, especially near switching frequencies, i.e., above 2 kHz. This paper evaluates the behaviour of high-frequency harmonics in the 2–20 kHz range due to the parallel operation of multiple solar PV inverters connected to a low-voltage (LV) network. The circulation current component that flows within the installation due to the low impedance paths at higher frequencies is analysed. Summation of high-frequency harmonic currents is observed with phase diversity analysis. The circulating current component can become 14 times higher than the grid current component at higher frequencies.

19 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
JDJason David
Jason David
PCPhilip Ciufo
Philip Ciufo
SESean Elphick
Sean Elphick
Duane RobinsonDuane Robinson
Duane Robinson
Low voltage devices connected to public electricity supply networks can be subjected to a wide range of voltage quality, including sustained overvoltage. Assessing the impact of sustained overvoltage on devices connected to the distribution network is important in determining the appropriate variance of standard voltage levels without unduly impacting the utility and customers from a technical and economic perspective. Therefore, a clear understanding of the impact that sustained overvoltage has on the lifetime of the connected equipment is a necessary task. This paper investigates the impact of sustained overvoltage through a series of accelerated-life testing experiments on a custom designed test device representative of a common interface between the power supply and distribution network, a switch mode power supply. The switch mode power supply with combined rectifier and filtering capacitor represents one of the most common front ends of LV equipment in modern appliances, and the work here concentrates on the impact of overvoltage on capacitor ageing. The results of the testing indicate that there is an accelerated ageing impact correlated with the applied voltage magnitude. Furthermore, analysis shows that mismatches between appliance voltage rating and sustained network voltage, leading to accelerated ageing, may result in premature device failure without the consumer being aware of the root cause.

1 November 2017
Verified
Conference Paper
Closed access
JDJason David
Jason David
SESean Elphick
Sean Elphick
MCMatthew Crawford
Matthew Crawford
Research at the Australian Power Quality & Reliability Centre has identified sustained overvoltage to be a common phenomenon with serious impacts on a range of components connected to the electricity supply network. Whilst there are many causes for the issue it has been determined that the continued proliferation of distributed energy resources like small scale PV solar systems, may have considerable influence on the network's voltage. This paper investigates the reasons behind the continued increase in voltage levels and the impact it is having on connected devices. Research and experimental work has been carried out to quantify these effects showing that overvoltage scenarios can be detrimental to equipment lifetimes. The components of interest presented here are AC motors and Switch Mode Power Supplies. Suggestions to further revise the allowable voltage range in Australian low voltage distribution networks are also presented in the interests of mitigating the stress placed on components.

29 March 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SESean Elphick
Sean Elphick
Duane RobinsonDuane Robinson
Duane Robinson
SPSarath Perera
Sarath Perera
JKJonathan Knott
Jonathan Knott
JDJason David
Jason David
GDGerrard Drury
Gerrard Drury
Voltage rise caused by high levels of distributed generation is manifesting as voltage regulation challenges for many electricity network service providers. In this environment it would be ideal to reduce supply voltage magnitudes, however, many network operators are hesitant to do so due to concerns related to consumer appliance performance at reduced supply voltage magnitudes. Voltage regulation requirements are defined by network standards and network service providers must ensure voltages remain within specified limits. Through an evaluation of domestic appliance performance when supplied at various voltage magnitudes, this paper examines the impact of varying voltage levels on residential appliances. Equipment energy demand, operation and actuation were monitored for each applied voltage magnitude. While no equipment failures were recorded, appliance behaviour varied significantly with applied voltage magnitude. Individual appliance conservation voltage reduction (CVR) factors have also been established. The results highlight the importance of good voltage regulation and provide substantiated appliance performance figures for future studies. The outcomes of this paper allow electricity network service providers to understand the implications of supply voltage magnitude on domestic appliance performance, whether it be understating of the impact of higher voltage magnitudes caused by distributed generation or implications of reducing voltage magnitudes to provide headroom for distributed generation integration.