This article describes the use of FLUENT software to simulate the heat transfer performance of U-tube heat exchangers in the ground source heap pump using the backfill materials of shape-stabilized phase change materials and crushed stone concrete. In this study, the shape-stabilized phase change material is a mixture of decanoic acid and lauric acid with the following mass concentration compositions: decanoic acid = 60%, silica = 10%, and expanded graphite = 6%. The mixture of shape-stabilized phase change material has a coefficient of thermal conductivity of 1.528 W/(m·K) and a latent heat of 109.2 kJ/kg. From the results of a 12-h simulation of the heat transfer dynamics, the heat exchange for a unit borehole depth of backfilling with shape-stabilized phase change material is 1.223 times the heat exchange for a unit borehole depth of backfilling with crushed stone concrete. In addition, the thermal influence radius of the backfill materials of shape-stabilized phase change material is 0.9 times of that of crushed stone concrete. As a result, under the same area of the buried pipes region, the shape-stabilized phase change material backfill can achieve a heat exchange 1.359 times that of crushed stone concrete backfill. Meanwhile, using shape-stabilized phase change material could contain the sustaining decline in coefficient of performance of heat pump at refrigerate condition to a certain extent and the appropriate physical parameters of phase change materials are also crucial.
A district heating (DH) system is one of the most important components of infrastructures in cold areas. Proper DH network design should balance the initial investment and the heat distribution cost of the DH network. Currently, this design is often based on a recommended value for specific pressure loss (R = ∆P/L) in the main lines. This will result in a feasible network design, but probably not be optimal in most cases. The paper develops a novel optimization model to facilitate the design by considering the initial investment in the pipes and the heat distribution costs. The model will generate all possible network scenarios consisting of different series of diameters for each pipe in the flow direction of the network. Then, the annuity on the initial investment, the heat distribution cost, and the total annual cost will be calculated for each network scenario, taking into account the uncertainties of the material prices and the yearly operating time levels. The model is applied to a sample DH network and the results indicate that the model works quite well, clearly identifying the optimal network design and demonstrating that the heat distribution cost is more important than the initial investment in DH network design.
Passive house standard buildings (PHSBs), characterized by exceptional airtightness, present a promising technology for attaining carbon neutrality by 2060. The level of building airtightness is closely associated with air infiltration, which significantly impacts building energy consumption. However, there has been insufficient analysis of air infiltration in highly airtight buildings across diverse climatic regions. The present study involves the numerical simulation of the air infiltration rate (AIR) in an airtight building under varying design conditions during winter and summer, followed by a comprehensive analysis of the corresponding energy demand associated with air infiltration. The simulation results indicate that the building’s AIR ranges from 125 to 423 m3/h, with an average of 189 m3/h under summer design conditions, and from 40 to 344 m3/h, with an average of 198 m3/h under winter design conditions. The statistical findings demonstrate distinct distribution patterns for AIR and energy demand across various climatic regions, exhibiting significant variations in values. The discussion emphasizes the substantial heating load associated with air infiltration, even at a building airtightness level of 0.5 h−1, highlighting the necessity of considering its impact in the design of highly airtight buildings. Furthermore, it is recommended to establish specific airtightness limits for buildings in different climatic regions of China. This study offers theoretical guidance for the airtightness design of highly airtight buildings.
This study proposes to use gas-fired boilers as peak shaving heat sources in heating substations due to their capability to increase the reliability, flexibility and heat capacity without the need to change the district heating network (DHN). However, the design and operational requirements with different connection modes for this kind of DH system are still not clear. This paper presents a systematic study on this kind of DH system, analyzes the connection modes of series and parallel connections between the gas-fired boilers and the heat exchangers. For each connection mode, we figured out the thermal balances and obtained the design and operational parameters including the supply temperatures of the heat exchangers, gas-fired boilers and their variations under different network temperature levels and the base load ratios (β). Under the series connection mode, the design supply temperature of the heat exchangers has no relation with the design peak shaving flow ratio (ω′); it decreases linearly along with smaller β, and the decreasing slope is higher with bigger temperature difference (Δt) of the DHN. However, the design supply temperatures of gas-fired boilers increase linearly when β and/or ω′ are smaller, and the increasing speed is proportional to Δt. For the parallel connection mode, the design supply temperatures of the heat exchangers and gas-fired boilers are all affected by β, ω′ and Δt. The former decreases when β and/or ω′ are smaller, while the latter increases at the same time. Finally, the design peak shaving flow ratio ω′ are determined for the peak boilers with series and parallel connection modes. The study provides a theoretical basis for the design and operation of the DH system with peak heating boilers in substations in order to reach a lower investment and higher efficiency.