Renewable energy sources (RES) are playing an increasingly important role in energy markets around the world. It is necessary to evaluate the benefits from a higher level of RES integration with respect to a more active cross-border transmission system. In particular, this paper focuses on the sustainable energy transitions for Finland and Italy, since they have two extreme climate conditions in Europe and quite different profiles in terms of energy production and demand. We developed a comprehensive energy system model using EnergyPLAN with hourly resolution for a reference year for both countries. The models include electricity, heat and transportation sectors. According to the current base models, new scenarios reflecting an RES increase in total fuel consumption have been proposed. The future shares of renewables are based on each nation’s potential. The outcomes of the new scenarios support the future national plans, showing how decarburization in an energy system can occur in relation to the European Roadmap 2030 and 2050. In addition, possible power transmission between Italy and Finland were investigated according to the vision of an integrated European energy system with more efficient cross-border activities.
An underfloor air distribution (UFAD) system integrated with a chilled ceiling (CC) cooling system may be a potential advanced heating, ventilation and air conditioning system in modern non-residential buildings with high sensible cooling loads. This article presents an experimental study concerning the effect of ceiling surface temperature and supply air velocity on the indoor air distribution in a room with UFAD as the internal and external sensible cooling loads change. The vertical distributions of indoor air temperature, air velocity and contaminant (CO 2 ) concentration were evaluated by vertical air temperature difference (VATD), turbulence intensity (TI) and contaminant removal effectiveness (CRE), respectively. The results showed that the average VATD, TI and CRE levels were 0.5°C–1.0°C, 31%–41% and 0.85–1.06 when both internal and external sensible cooling loads were 41.5 W/m 2 . These evaluation indices varied clearly when the external sensible cooling load increased from 41.5 W/m 2 to 69.5 W/m 2 , whereas they remained almost the same when the internal sensible cooling load increased from 41.5 W/m 2 to 69.5 W/m 2 . The maximum TI coincided with the minimum CRE under the condition of a constant sensible cooling load. Moreover, an air diffusion performance index clearly reduced with an increase in the heat removal effectiveness. It is recommended that it is important to balance the indoor air quality and energy consumption in a room with UFAD + CC.
The thermal comfort of preschool children was assumed to be similar to that of young adults, which may cause inaccuracy. This study tested and analyzed the thermal response characteristics of young adults and preschool children (4–6 years old) and the differences in thermal sensation and thermal physiology between the two groups of participants in a room with a radiant floor heating system using the difference analysis methods (the paired data t-test, the Mann–Whitney U test and the Kruskal–Wallis H test). Participants were divided into two groups, young adults and preschoolers, and were sat in each condition while wearing winter clothing with a thermal resistance of 1.02 clo. The results showed that when the indoor temperature changed, there was a significant difference in the local skin temperature of the calf between the two groups of participants (p < 0.05). Preschool children adapt to the thermal environment better than adults, and the difference in metabolic rate is one of the influencing factors. The overall thermal sensation with mean skin temperature of the different populations was linearly correlated; correlation coefficients were 0.944 and 0.932, respectively. The overall thermal sensation of the participants was linear with respect to the indoor operative temperature. Preschool children have a higher thermal sensitivity to temperature change than young adults under low-temperature radiant floor heating systems, indicating that children have different thermal awareness from adults. There were significant differences in preschoolers’ subjective assessments of thermal sensation when the predicted mean vote (PMV) model was used as the evaluation standard; the difference ranged from 0.77 to 2.33. Thus, the PMV-predicted percentage dissatisfied (PPD) model is not suitable for preschool children.
A mixing ventilation system integrated with a ceiling cooling system is a potential advanced heating, ventilation and air conditioning system for modern office buildings with a high sensible cooling load. This paper presents an evaluation of the effect of sensible cooling load on the indoor air distribution in a typical office room with mixing ventilation and ceiling cooling. The vertical distributions of indoor air temperature, air velocity and contaminant (CO2) concentration were evaluated by the vertical air temperature difference, turbulence intensity and contaminant removal effectiveness. The results showed that when the chilled ceiling surface temperature was increased from 15.0°C to 23.0°C and supply air temperature was decreased from 22.0°C to 19.0°C, the average vertical air temperature difference, turbulence intensity and contaminant removal effectiveness were 0.2°C–0.3°C, 27%–32% and 0.53–0.81 as both internal and external sensible cooling loads were 41.5 W/m2. Moreover, these evaluation indices varied slightly as the external sensible cooling load was increased from 41.5 W/m2 to 69.5 W/m2, whereas they varied greatly as the internal sensible cooling load was increased from 41.5 W/m2 to 69.5 W/m2. Hence, the external sensible cooling load could slightly affect the indoor air distribution, whereas the internal sensible cooling load could clearly affect the indoor air distribution in an office room with mixing ventilation and ceiling cooling.