Xiangli Li

Dr. Xiangli Li

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2017 in Energies
Verified
Journal Article
Open access
PDF file
HWHaichao Wang
Haichao Wang
LDLin Duanmu
Lin Duanmu
XLXiangli Li
Xiangli Li
RLRisto Lahdelma
Risto Lahdelma
A district heating (DH) system is one of the most important components of infrastructures in cold areas. Proper DH network design should balance the initial investment and the heat distribution cost of the DH network. Currently, this design is often based on a recommended value for specific pressure loss (R = ∆P/L) in the main lines. This will result in a feasible network design, but probably not be optimal in most cases. The paper develops a novel optimization model to facilitate the design by considering the initial investment in the pipes and the heat distribution costs. The model will generate all possible network scenarios consisting of different series of diameters for each pipe in the flow direction of the network. Then, the annuity on the initial investment, the heat distribution cost, and the total annual cost will be calculated for each network scenario, taking into account the uncertainties of the material prices and the yearly operating time levels. The model is applied to a sample DH network and the results indicate that the model works quite well, clearly identifying the optimal network design and demonstrating that the heat distribution cost is more important than the initial investment in DH network design.

13 March 2024 in Energy and Buildings
Verified
Journal Article
Closed access
CCChang Chang
Chang Chang
XLXiangli Li
Xiangli Li
LDLin Duanmu
Lin Duanmu
BSBing Sun
Bing Sun
HJHengjin Ju
Hengjin Ju

11 November 2016 in Chemical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
XLXiangli Li
Xiangli Li
GLGuohui Li
Guohui Li


24 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
XLXiangli Li
Xiangli Li
HWHaichao Wang
Haichao Wang
XWXiaozhou Wu
Xiaozhou Wu
LDLin Duanmu
Lin Duanmu
ETEsa Teppo
Esa Teppo
LYLi Yu
Li Yu
This study proposes to use gas-fired boilers as peak shaving heat sources in heating substations due to their capability to increase the reliability, flexibility and heat capacity without the need to change the district heating network (DHN). However, the design and operational requirements with different connection modes for this kind of DH system are still not clear. This paper presents a systematic study on this kind of DH system, analyzes the connection modes of series and parallel connections between the gas-fired boilers and the heat exchangers. For each connection mode, we figured out the thermal balances and obtained the design and operational parameters including the supply temperatures of the heat exchangers, gas-fired boilers and their variations under different network temperature levels and the base load ratios (β). Under the series connection mode, the design supply temperature of the heat exchangers has no relation with the design peak shaving flow ratio (ω′); it decreases linearly along with smaller β, and the decreasing slope is higher with bigger temperature difference (Δt) of the DHN. However, the design supply temperatures of gas-fired boilers increase linearly when β and/or ω′ are smaller, and the increasing speed is proportional to Δt. For the parallel connection mode, the design supply temperatures of the heat exchangers and gas-fired boilers are all affected by β, ω′ and Δt. The former decreases when β and/or ω′ are smaller, while the latter increases at the same time. Finally, the design peak shaving flow ratio ω′ are determined for the peak boilers with series and parallel connection modes. The study provides a theoretical basis for the design and operation of the DH system with peak heating boilers in substations in order to reach a lower investment and higher efficiency.

15 September 2023 in Buildings
Verified
Journal Article
Open access
PDF file
XWXiaozhou Wu
Xiaozhou Wu
HGHao Gao
Hao Gao
MZMingming Zhao
Mingming Zhao
JGJie Gao
Jie Gao
ZTZhen Tian
Zhen Tian
XLXiangli Li
Xiangli Li
A ceiling cooling system integrated with a mechanical ventilation system has been widely used in modern buildings with large sensible cooling loads due to the high thermal comfort level and large energy efficiency. However, there is a lack of systematic research on the influence factors such as ceiling surface temperature and cooling load on the indoor air distribution and thermal environment, and the impact of ventilation system type in the ceiling cooling room is still unclear. Therefore, this paper presented an experimental study of indoor air distribution and thermal environment in a ceiling cooling (CC) room with mixing ventilation (MV), underfloor air distribution (UFAD) and stratum ventilation (SV); the ceiling surface temperature was 17 °C–26 °C and the internal or external cooling load was 41.5 W/m2–69.5 W/m2. The results showed that the vertical air temperature difference and contaminant removal effectiveness were 0.2 °C–0.4 °C and 0.53–0.85 with CC + MV, 0 °C–1.2 °C and 0.68–1.25 with CC + UFAD and 0.3 °C–0.9 °C and 0.50–0.83 with CC + SV, and the corresponding heat removal effectiveness and air diffusion performance index were 0.96–1.11 and 96–100%, 0.9–1.5 and 57–100% and 1.11–1.34 and 71–100%, respectively. Moreover, the difference between mean radiant temperature and air temperature and the predicted mean vote of thermal sensation were from 0 °C to 0.9 °C and between 0 and 0.26 with CC + MV, from −0.1 °C to 2.2 °C and between −0.1 and 0.42 with CC + UFAD and from −0.1 °C to 0.9 °C and between −0.2 and 0.13 with CC + SV. Hence, the ventilation system type clearly affected the indoor air distribution and thermal environment in the ceiling cooling room, and the experimental results would be beneficial for the design and control of a ceiling cooling system combined with a mechanical ventilation system in practice.