1 October 2020 in Flow Measurement and Instrumentation
Verified
Journal Article
Open access
EBElsa Batista
Elsa Batista
IGIsabel Godinho
Isabel Godinho
Rui F. MartinsRui F. Martins
Rui F. Martins
RMRicardo Mendes
Ricardo Mendes
JRJoão Robarts
João Robarts

1 January 2015 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
EBElsa Batista
Elsa Batista
NANelson Almeida
Nelson Almeida
AFAndreia Furtado
Andreia Furtado
EFEduarda Filipe
Eduarda Filipe
LSLuis Sousa
Luis Sousa
ATAnnemoon Timmerman
Annemoon Timmerman
For critical drug delivery, it is important to have a constant and well-known infusion rate delivered by the complete infusion set-up (pump, tubing, and accessories). Therefore, various drug delivery devices and accessories were tested in this article in terms of their infusion accuracy, start-up delay, response time, and dependency on the viscosity. These measurements were performed as part of the European funded research project MeDD. The obtained results show that the infusion accuracy of the devices is flow rate and accessory depended, especially for low flow rates. Viscosity does not have a significant impact on the flow rate accuracy.

1 March 2020 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
EBElsa Batista
Elsa Batista
JSJoão Alves Alves e Sousa
João Alves Alves e Sousa
Susana Cardoso De FreitasSusana Cardoso De Freitas
Susana Cardoso De Freitas
Vania SilverioVania Silverio
Vania Silverio

8 November 2022 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Open access
PDF file
EBElsa Batista
Elsa Batista
MÁMiguel Álvares
Miguel Álvares
Rui F. MartinsRui F. Martins
Rui F. Martins
FOFlorestan Ogheard
Florestan Ogheard
JGJan Geršl
Jan Geršl
IGIsabel Godinho
Isabel Godinho
Objectives: Microflow measurement devices are used in several science and health applications, mainly drug delivery. In the last decade, several new methods based on optical technology were developed, namely the front tracking and interferometric method, in which the knowledge of the inner diameter of the syringe or the capillary used is critical. Only a few National Metrology Institutes (NMIs) can perform inner diameter measurements below 1 mm, which requires expensive technology. Therefore, IPQ, in cooperation with CETIAT, CMI and UNIDEMI, under the EMPIR project 18HLT08 MeDDII – Metrology for Drug Delivery, developed new measurement methods for small inner diameter tubes based on the gravimetric principle and optical methods in order to simplify the apparatus used for this type of measurements without increasing uncertainty. Methods: The gravimetric experimental setup consists of measuring the liquid volume on a specific length of the glass tube. The optical method used is based on the front track principle that uses a high-resolution camera and ImageJ software, to determine the diameter at both ends of each capillary. Results: To validate the developed methods, a comparison was performed between CETIAT, CMI and IPQ and the results obtained were all consistent. Conclusions: This work allowed the determination of inner diameter of syringes or capillaries using two different methods with relative expanded uncertainties from 0.1 to 0.5% (k=2), that can be applied for flow measurements using optical technology.

6 May 2024 in Metrology
Verified
Journal Article
Open access
PDF file
EBElsa Batista
Elsa Batista
JSJoão Alves Alves e Sousa
João Alves Alves e Sousa
FSFernanda Saraiva
Fernanda Saraiva
ALAndré Lopes
André Lopes
Vania SilverioVania Silverio
Vania Silverio
Luís Filipe Lages MartinsLuís Filipe Lages Martins
Luís Filipe Lages Martins
Dimensional measurements are fundamental in microfluidic device manufacturing and performance. The main focus of this study is the measurement of the connection port sizes in microfluidic devices and components and, accordingly, the possible existence of fluid leaks determined using the flow rate error. The sizes associated with three different microfluidic systems were determined using laser interferometry and through an optical measuring instrument, with metrological traceability to national length standards. It was possible to infer the method with the greatest accuracy and lowest measurement uncertainty for characterizing this kind of system. In conclusion, the results of this work directly address the current lack of dimensions measuring methods of microfluidic components by providing a comprehensive comparison of different protocols, ultimately suggesting a preferred option for immediate application within the microfluidic industry.

14 November 2017 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
EBElsa Batista
Elsa Batista
IGIsabel de Araúho Godinho
Isabel de Araúho Godinho
MFMaria Do Céu Ferreira
Maria Do Céu Ferreira
AFAndreia Furtado
Andreia Furtado
PLPeter Lucas
Peter Lucas
CSClaudia Silva
Claudia Silva
Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.