Effects of hot pixels on pixel performance in light and dark environments have been investigated in pinned photodiode 0.18 μm backside illuminated CMOS image sensors irradiated by 10 MeV protons. After exposure to protons, hot pixels and normal pixels are selected from the whole pixel array, and their influences on key parameters are analyzed. Experimental results show that radiation-induced hot pixels have a significant impact on pixel performance in dark environments, such as dark signal nonuniformity, long integration time, and random telegraph signal. Hot pixels are caused by defects with complex structures, i.e., cluster defects. Furthermore, the dark current activation energy result confirms that the defects causing the hot pixels have defect energy levels close to mid-gap.
Single Event Upsets (SEUs) are most likely to cause bit flips within the trained parameters of a convolutional neural network (CNN). Therefore, it is crucial to analyze and implement hardening techniques to enhance their reliability under radiation. In this paper, random fault injections into the weights of LeNet-5 were carried out in order to evaluate and propose strategies to improve the reliability of a CNN. According to the results of an SEU fault injection, the accuracy of the CNN can be classified into the following three categories: benign conditions, poor conditions, and critical conditions. Two efficient methods for mitigating weight-related SEUs are proposed, as follows: weight limiting and Triple Modular Redundancy (TMR) for the critical bit of the critical layer. The hardening results show that when the number of SEU faults is small, the weight limiting almost completely eliminates the critical and poor conditions of LeNet-5’s accuracy. Additionally, even when the number of SEU faults is large enough, combining the weight limiting and TMR methods for the critical bit of the critical layer can retain the occurrence rate of benign conditions at 98%, saving 99.3% of the hardware resources compared to the Full-TMR hardening method.
High-energy particles in space often induce single event effects in CMOS image sensors, resulting in performance degradation and functional failure. This paper focuses on the formation and morphology of transient bright spots in CMOS image sensors and analyzes the formation process of transient bright spots by conducting heavy ion irradiation experiments to obtain the variation law of transient bright spots with heavy ion linear energy transfer values and background gray values; in addition, we classify the single event upset that occurred in the experiments according to the state of transient bright spots and extract the characteristics of different single event upsets. The failure mechanisms of different single event upsets are analyzed according to their characteristics and are combined with the information given by transient bright spots. This provides an essential reference for rapidly evaluating single event effects and the reinforcement design of CMOS image sensors.
Star sensors play a crucial role as high-precision optical attitude navigation devices in satellite attitude control systems. The CMOS image sensor is an important component of the imaging system of the star sensor and experiences performance degradation due to the total ionizing dose effect and displacement damage effect in the radiation environment of its long-term operational workspace. As a result, the detection capability and attitude positioning accuracy of the star sensor gradually deteriorate. The performance of CMOS image sensors can be partially restored after annealing but the impact on the performance of star sensors is unclear. This study conducted 100 MeV proton irradiation experiments with different fluences on CMOS image sensors and performed room temperature and high temperature annealing treatments. By testing and analyzing the performance of star sensors equipped with irradiated and different annealing treatments on CMOS image sensors, the impact mechanism of CMOS image sensor radiation damage and annealing recovery on the performance variation of star sensors was obtained. This study provides theoretical support for reliability of long-term in-orbit star sensors.
10 July 2024 in IEEE Transactions on Nuclear Science
The space optoelectronic imaging systems are susceptible to the impact of high-energy particle irradiation during on-orbit operations, leading to dark current increase and various types of pixel anomalies, which degrades device performance. Heavy ion and proton irradiation experiments on 8T-CMOS image sensors are conducted to investigate the characteristics of dark current distributions and hot pixels. Additionally, cold pixels are observed in 8T-image sensors. The results demonstrate that dark current increases with increasing fluence, coupled with SRIM simulations, Coulombic elastic scattering can be identified as the main cause for dark current increases due to proton and heavy ion irradiations, the value of scattering cross-sections may ultimately lead to offsets in the universal damage factor. A common exponential behavior is observed, integrating heavy ions into the existing theoretical framework, temperature dependence and annealing of exponential behavior are also discussed. Both hot pixels and cold pixels can be attributed to defects induced by particle irradiation, with the difference that the defects causing hot pixels are located near the pinned photodiode, while the defects causing cold pixels are located in a specific capacitance of the 8T-CMOS image sensor.
23 September 2024 in IEEE Transactions on Nuclear Science
We recently evaluate the high total ionizing dose (TID) effects on 0.18 μm backside illuminated CMOS image sensors (BSI CIS) with different epitaxial layer thicknesses and backside oxide passivation techniques. γ-irradiated device exhibits a huge dark current increase and quantum efficiency degradation. Moreover, a significant dark current nonuniformity on the whole array is observed at high TID. Results show that the BSI CIS does not capture images and all the functionality is lost after 4 Mrad(SiO 2 ). It is observed that BSI CIS using Al2O3 film as passivation technique is proven to be more efficient in mitigating high TID effects compared to the imagers using boron implant, suggesting that passivation technique options play a crucial role in determining the performance of BSI CIS at high TID level.