Zitao Zhao

Zitao Zhao

Auto-generated profile, based on publicly available information

Zitao Zhao

XinJiang Technical Institute of Physics and Chemistry, Xinjiang Key Laboratory of Extreme Environment Electronics, People’s Republic of China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
ZZZitao Zhao
Zitao Zhao
LWLin Wen
Lin Wen
YLYudong Li
Yudong Li
JFJie Feng
Jie Feng
BLBingkai Liu
Bingkai Liu
QGQi Guo
Qi Guo
As a power management chip widely used in various electronic systems, the low dropout regulator (LDO) plays a crucial role in the normal operation of electronic systems. Ionizing radiation and electromagnetic pulse (EMP) radiation can cause interference and damage to the LDO, posing risks to the proper functioning of electronic systems in large-scale scientific devices. In this study, through separate experimental investigations on the Total Ionizing Dose (TID) effects, EMP effects, and synergistic effect of the LDO, it was found that parameters such as the LDO output voltage decreases with increasing irradiation dose, with more severe degradation observed under grounded bias. The EMP effects mainly cause oscillations in the LDO output voltage and a slight increase in its mean value. The results of the synergistic effect experiments indicate that there is a certain synergistic interaction between the TID effects and the EMP effects. The synergistic effects lead to an increase in the amplitude of the oscillations and changes in the mean value of the output voltage.

10 July 2024 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
ZZZitao Zhao
Zitao Zhao
LWLin Wen
Lin Wen
YLYu-Dong Li
Yu-Dong Li
BLBingkai Liu
Bingkai Liu
JFJie Feng
Jie Feng
QGQi Guo
Qi Guo
The space optoelectronic imaging systems are susceptible to the impact of high-energy particle irradiation during on-orbit operations, leading to dark current increase and various types of pixel anomalies, which degrades device performance. Heavy ion and proton irradiation experiments on 8T-CMOS image sensors are conducted to investigate the characteristics of dark current distributions and hot pixels. Additionally, cold pixels are observed in 8T-image sensors. The results demonstrate that dark current increases with increasing fluence, coupled with SRIM simulations, Coulombic elastic scattering can be identified as the main cause for dark current increases due to proton and heavy ion irradiations, the value of scattering cross-sections may ultimately lead to offsets in the universal damage factor. A common exponential behavior is observed, integrating heavy ions into the existing theoretical framework, temperature dependence and annealing of exponential behavior are also discussed. Both hot pixels and cold pixels can be attributed to defects induced by particle irradiation, with the difference that the defects causing hot pixels are located near the pinned photodiode, while the defects causing cold pixels are located in a specific capacitance of the 8T-CMOS image sensor.

13 April 2026 in The Astronomical Journal
Verified
Journal Article
Open access
QFQi Feng
Qi Feng
ZLZiyi Liu
Ziyi Liu
HZHongfei Zhang
Hongfei Zhang
王 坚王 坚
王 坚
JGJian Ge
Jian Ge
XWXinbo Wang
Xinbo Wang
Optical astronomical projects have traditionally relied on charge-coupled device (CCD) detectors. However, next-generation complementary metal-oxide-semiconductor (CMOS) technology, with advantages including high-speed readout, low dark current, and electronic shutter capability, is reshaping observational strategies and substantially improving observing efficiency. Many ground-based facilities are now transitioning from CCDs to scientific CMOS (sCMOS) detectors, yet the long-term radiation-induced performance degradation of sCMOS devices in space environments has not been systematically characterized. In this work, we irradiate a GSENSE1081BSI sCMOS detector under representative on-orbit operating conditions, including vacuum and low temperature, and continuously monitor its performance during both the irradiation and subsequent annealing phases. Based on the measured evolution of key detector parameters, we predict the corresponding on-orbit degradation of photometric signal-to-noise ratio. The predicted performance meets the requirements of the microlensing telescope of the forthcoming Earth 2.0 mission, demonstrating the suitability of this detector for space-based time-domain observations and for potential application in future space missions. Our results further provide quantitative benchmarks and practical guidance for ground-based radiation testing of sCMOS detectors and for assessing their long-term performance evolution in space.

1 November 2026 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
BWBin Wang
Bin Wang
YLYu-Dong Li
Yu-Dong Li
DZDong Zhou
Dong Zhou
LWLin Wen
Lin Wen
BLBingkai Liu
Bingkai Liu
QGQi Guo
Qi Guo