Eva González-Angulo

Dr. Eva González-Angulo

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2023 in Materials
Verified
Journal Article
Open access
PDF file
EGEva González-Angulo
Eva González-Angulo
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
JCJavier Casas-Terrón
Javier Casas-Terrón
GSGisela Senent-Vicente
Gisela Senent-Vicente
CBCarla Fons Badal
Carla Fons Badal
JRJuan Luis Román-Rodríguez
Juan Luis Román-Rodríguez
Introduction: Today’s dentistry frequently employs bonded partial restorations, which are usually fabricated in ceramic materials. In the last decade, hybrid materials have emerged that attempt to combine the properties of composites and ceramics. Objectives: To evaluate in vitro, by means of a microtensile test, the bond strength between CAD-CAM restorative materials and the cement recommended by their manufacturer. Material and Method: From blocks of CAD-CAM restorative material bonded to composite blocks (Filtek 500®), beams with a bonding area of approximately 1 mm2 were made and divided into four groups: EMAX (IPS e.max CAD® lithium disilicate), VE (VITA Enamic® polymer-infiltrated ceramic matrix), LUA (Lava Ultimate® nano-ceramic resin with sandblasting protocol) and LUS (Lava Ultimate® nano-ceramic resin with silica coating protocol). In each group, perimeter (external) or central (internal) beams were differentiated according to the position in the block. The samples were tested on the LMT 100® microtensile machine. Using optical microscopy, the fractures were categorized as adhesive or cohesive (of the restorative material or composite), and the data were analysed with parametric tests (ANOVA). Results: The LUS group had the highest results (42 ± 20 MPa), followed by the LUA group (38 ± 18 MPa). EMAX had a mean of 34 ± 16 MPa, and VE was the lowest in this study (30 ± 17 MPa). In all groups, the central beams performed better than the perimeter beams. Both EMAX and VE had the most adhesive fractures, while LUA and LUS had a predominance of cohesive fractures. Conclusions: Lava Ultimate® nanoceramic resin with the silica coating protocol obtains the best bond strength values.

24 November 2023 in Materials
Verified
Journal Article
Open access
PDF file
GSGisela Senent-Vicente
Gisela Senent-Vicente
MBMar Baixauli-López
Mar Baixauli-López
EGEva González-Angulo
Eva González-Angulo
LFLuisa Fernández-Bravo
Luisa Fernández-Bravo
ÁZÁlvaro Zubizarreta-Macho
Álvaro Zubizarreta-Macho
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
Statement of problem: The extraction of fractured abutment screws can be a difficult challenge to overcome. Purpose: To compare the removal capacity, dental implant connection damage, and time required to remove the fractured abutment screws between three drilling techniques and a conventional method. Materials and methods: A total of 180 prefabricated screw-retained abutments were intentionally fractured in internal connection dental implants after being subjected to a cyclic load and a static compression load. Afterwards, three operators randomly removed the fractured abutment screws with the following drilling techniques and a conventional method: A: a conventional technique using an exploration probe and ultrasonic appliance (n = 45), Rhein83® (n = 45); B: Sanhigia® (n = 45); C: Phibo® (n = 45). Two-way ANOVA models were estimated to evaluate the mean time according to the method and operator used. Results: The probability of removal of the screws with mobility was twelve times higher than that of the screws without mobility (OR = 12.4; p < 0.001). The success rate according to the operators did not show statistically significant differences (p = 0.371). The location of the fractured screw did not affect removal success (p = 0.530). The internal thread of the implant was affected after the removal process in 9.8% of the cases. The mean extraction time was 3.17 ± 2.52 min. The Rhein83® method showed a success rate of 84.4%, followed by the Phibo® and conventional methods (71.1%) and the Sanhigia® method (46.7%). Conclusions: The Rhein83® drilling technique increases the removal probability of fractured abutment screws. The initial mobility of the fragment is also a significant factor in the removal success.

2 August 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
SRSilvia del Cid Rodríguez
Silvia del Cid Rodríguez
CBCarmen Carda Batalla
Carmen Carda Batalla
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
EGEva González-Angulo
Eva González-Angulo
JRJuan Luis Román-Rodríguez
Juan Luis Román-Rodríguez
Background: Bonding to sclerotic dentin remains one of the most challenging procedures in restorative dentistry due to tubular occlusion and hypermineralization, which limit resin infiltration. This study evaluated the influence of adhesive system, surface treatment, storage time, and substrate position on microtensile bond strength (µTBS) to natural sclerotic dentin. Methods: Sixteen extracted human molars with sclerotic dentin were selected and randomly assigned to nine experimental groups according to the adhesive system and surface treatment. Three adhesives were tested: a two-step self-etch adhesive (Clearfil SE Bond 2, Kuraray Noritake Dental, Tokyo, Japan) and two universal adhesives, one containing 10-MDP (G-Premio Bond, GC Corp., Tokyo, Japan) and one without 10-MDP (iBond Universal, Kulzer GmbH, Hanau, Germany). Each adhesive was applied under three conditions: no pretreatment (control), Al2O3 air-abrasion, and Bioglass 45S5 (ProSylc®, Velopex International, London, UK) air-abrasion. Composite build-ups were performed, and the specimens were sectioned into 1 mm2 beams for microtensile testing either after 24 h or after 6 months of storage in distilled water at 37 °C of hypertonic solution. The effect of beam position (central vs. peripheral) was also analyzed. Bond strength was measured by µTBS testing, and the results were analyzed using multifactorial ANOVA and Tukey’s test (α = 0.05). Failure modes were examined under stereomicroscopy, whereas optical microscopy was used for qualitative evaluation of representative fractured interfaces. Results: Significant main effects were found for adhesive system and surface treatment (p < 0.001), with a notable interaction between them (p < 0.05). Al2O3 air-abrasion produced the highest bond strengths, particularly for the self-etch adhesive containing functional monomers (53.4 ± 6.1 MPa), representing a 53% increase over the untreated control. Bioglass air-abrasion did not enhance adhesion and led to irregular hybrid layers. The position of the beams affected only one universal adhesive, with higher µTBS in peripheral regions. After six months of water storage, bond strengths remained stable across most groups, indicating good hydrolytic resistance of the interfaces. Conclusions: Both the adhesive system and the surface treatment significantly influenced bonding effectiveness to sclerotic dentin. The combination of Al2O3 air-abrasion with an MDP-containing self-etch adhesive achieved the most durable and homogeneous bond interface. providing a clinically reliable protocol for restorative treatments in sclerotic dentin. Within the limitations of this in vitro study, this combination may represent a potentially useful strategy for improving adhesion to sclerotic dentin, although further investigations are required to confirm its clinical applicability.

23 October 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
SLShujing Lyu
Shujing Lyu
EGEva González-Angulo
Eva González-Angulo
Oral squamous cell carcinoma (OSCC) accounts for approximately 90% of oral malignancies, and most cases arise from oral potentially malignant disorders (OPMDs) against a background of chronic inflammation. Periodontitis, a highly prevalent chronic inflammatory disease, is increasingly implicated as a risk factor for OSCC, yet the mechanistic link between these conditions remains unclear. This review proposes that immunosenescence—the age-related decline in immune function—may provide this link. We synthesise evidence indicating that periodontitis promotes immune ageing in oral and systemic immune compartments, encompassing T-cell exhaustion, the accumulation of senescent immune cells, and a pro-inflammatory senescence-associated secretory phenotype (SASP); together, these changes progressively weaken local immunosurveillance. On this basis, we introduce the “immune-senescent switch” as a conceptual framework—explicitly distinguished from established evidence—in which senescence is hypothesised to initially act as a tumour-suppressive barrier in early OPMDs but to be converted into a tumour-promoting force by chronic, periodontitis-driven immunosenescence. We critically evaluate the supporting evidence, including the single-arm phase 2 COIS-01 trial (n = 24), in which senolytics combined with anti-PD-1 therapy achieved a 33.3% major pathological response rate in resectable head and neck squamous cell carcinoma, while emphasising the preliminary, hypothesis-generating nature of these data. Finally, we discuss emerging senotherapeutic strategies, translational gaps, and future research priorities.

24 September 2026 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
ACAna Cases-Sánchez
Ana Cases-Sánchez
EGEva González-Angulo
Eva González-Angulo
AFAlexandra Flesariu-Onu
Alexandra Flesariu-Onu
CFCarla Fons-Badal
Carla Fons-Badal
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan