Rubén Agustín Panadero

Dr. Rubén Agustín Panadero

Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MRMarta Revilla-León
Marta Revilla-León
ESElena Sicilia
Elena Sicilia
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
MGMiguel Gómez-Polo
Miguel Gómez-Polo
JKJohn C. Kois
John C. Kois

2 December 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Alfonso Mediavilla GuzmánAlfonso Mediavilla Guzmán
Alfonso Mediavilla Guzmán
EDElena Riad Deglow
Elena Riad Deglow
ÁZÁlvaro Zubizarreta-Macho
Álvaro Zubizarreta-Macho
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
SMSofía Hernández Montero
Sofía Hernández Montero
Aim: To analyze the accuracy capability of two computer-aided navigation procedures for dental implant placement. Materials and Methods: A total of 40 dental implants were selected, which were randomly distributed into two study groups, namely, group A, consisting of those implants that were placed using a computer-aided static navigation system (n = 20) (guided implant (GI)) and group B, consisting of those implants that were placed using a computer-aided dynamic navigation system (n = 20) (navigation implant (NI)). The placement of the implants from group A was performed using surgical templates that were designed using 3D implant-planning software based on preoperative cone-beam computed tomography (CBCT) and a 3D extraoral surface scan, and the placement of group B implants was planned and performed using the dynamic navigation system. After placing the dental implants, a second CBCT was performed and the degree of accuracy of the planning and placement of the implants was analyzed using therapeutic planning software and Student’s t-test. Results: The paired t-test revealed no statistically significant differences between GI and NI at the coronal (p = 0.6535) and apical (p = 0.9081) levels; however, statistically significant differences were observed between the angular deviations of GI and NI (p = 0.0272). Conclusion: Both computer-aided static and dynamic navigation procedures allow accurate implant placement.

2 January 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ÁZÁlvaro Zubizarreta-Macho
Álvaro Zubizarreta-Macho
AMAna de Pedro Muñoz
Ana de Pedro Muñoz
EDElena Riad Deglow
Elena Riad Deglow
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
JMJesús Mena-Álvarez
Jesús Mena-Álvarez
Purpose: To analyze the accuracy of two computer-aided navigation techniques to guide the performance of endodontic access cavities compared with the conventional access procedure. Materials and Methods: A total of 30 single-rooted anterior teeth were selected, which were randomly distributed into three study groups: Group A—guided performance of endodontic access cavities through computer-aided static navigation system (n = 10) (SN); Group B—guided performance of endodontic access cavities through computer-aided dynamic navigation system (n = 10) (DN); and Group C—manual (freehand) performance of endodontic access cavities (n = 10) (MN). The endodontic access cavities of the SN group were performed with a stereolithography template designed on 3D implant planning software, based on preoperative cone-beam computed tomography (CBCT) and a 3D extraoral surface scan, and endodontic access cavities of the DN group were planned and performed by the dynamic navigation system. After endodontic access cavities were performed, a second CBCT was done, and the degree of accuracy between the planned and performed endodontic access cavities was analyzed using therapeutic planning software and Student’s t-test. Results: Paired t-test revealed no statistically significant differences between SN and DN at the coronal (p = 0.6542), apical (p = 0.9144), or angular (p = 0.0724) level; however, statistically significant differences were observed between the two computer-aided navigation techniques and the MN group at the coronal (p < 0.0001), apical (p < 0.0001), and angular (p < 0.0001) level. Conclusion: Both computer-aided static and dynamic navigation procedures allowed accurate performance of endodontic access cavities.

NHNaia Bustamante Hernández
Naia Bustamante Hernández
JMJosé María Montiel-Company
José María Montiel-Company
CBCarlos Bellot-Arcis
Carlos Bellot-Arcis
JFJOSE FELIX MAÑES FERRER
JOSE FELIX MAÑES FERRER
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
A systematic review and meta-analysis was performed to analyze the survival of onlay restorations in the posterior region, their clinical behavior according to the material used (ceramic reinforced with lithium disilicate, conventional feldspathic ceramic or reinforced with leucite; hybrid materials and composite), possible complications, and the factors influencing restoration success. The systematic review was based on the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement, without publication date or language restrictions. An electronic search was made in the PubMed, Scopus, Embase, and Cochrane databases. After discarding duplicate publications and studies that failed to meet the inclusion criteria, the articles were selected based on the population, intervention, comparison, outcome (PICO) question. The following variables were considered in the qualitative and quantitative analyses: restoration survival rate (determined by several clinical parameters), the influence of the material used upon the clinical behavior of the restorations, and the complications recorded over follow-up. A total of 29 articles were selected for the qualitative analysis and 27 for the quantitative analysis. The estimated restoration survival rate was 94.2%. The predictors of survival were the duration of follow-up (beta = −0.001; p = 0.001) and the onlay material used (beta = −0.064; p = 0.028). Composite onlays were associated with a lower survival rate over time. Onlays are a good, conservative, and predictable option for restoring dental defects in the posterior region, with a survival rate of over 90%. The survival rate decreases over time and with the use of composite as onlay material.

1 January 2014 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
JRJl. Roman-Rodriguez
Jl. Roman-Rodriguez
AFA. Ferreiroa
A. Ferreiroa
MSMf. Sola-Ruiz
Mf. Sola-Ruiz
AFA. Fons-Font
A. Fons-Font
Evidence is limited on the efficacy of zirconia-based fixed dental prostheses. To carry out a literature review of the behavior of zirconium oxide dental restorations. This literature review searched the Pubmed, Scopus, Medline and Cochrane Library databases using key search words "zirconium oxide," "zirconia," "non-metal restorations," "ceramic oxides," "veneering ceramic," "zirconia-based fixed dental prostheses". Both in vivo and in vitro studies into zirconia-based prosthodontic restoration behavior were included. Clinical studies have revealed a high rate of fracture for porcelain-veneered zirconia-based restorations that varies between 6% and 15% over a 3- to 5-year period, while for ceramo-metallic restorations the fracture rate ranges between 4 and 10% over ten years. These results provoke uncertainty as to the long-term prognosis for this material in the oral medium. The cause of veneering porcelain fractures is unknown but hypothetically they could be associated with bond failure between the veneer material and the zirconia sub-structure. Key words:Veneering ceramic, zirconia-based ceramic restoration, crown, zirconia, tooth-supported fixed prosthesis.

9 November 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AAAmaia Amesti
Amaia Amesti
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
BVBlanca Verdejo-Solá
Blanca Verdejo-Solá
AFAntonio Fons-Font
Antonio Fons-Font
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
Background: The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. Materials and methods: This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health (PubMed), Scopus, Web of Science (WOS), and Embase. In vitro trials published during the last 10 years were included in the review. Results: Applying inclusion criteria based on the review’s population, intervention, comparison, outcome (PICO) question, 13 articles were selected. Meta-analysis by restoration type estimated the fracture resistance of inlays to be 1923.45 Newtons (N); of onlays 1644 N and of overlays 1383.6 N. Meta-analysis by restoration material obtained an estimated fracture resistance for ceramic of 1529.5 N, for composite resin of 1600 Ne, for resin nanoceramic 2478.7 N, and hybrid ceramic 2108 N. Conclusions: Resin nanoceramic inlays present significantly higher fracture resistance values. Proximal box elevation does not exert any influence on the fracture resistance of indirect restorations.