Lucia Fernandez-Estevan

Prof. Lucia Fernandez-Estevan

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
NHNaia Bustamante Hernández
Naia Bustamante Hernández
JMJosé María Montiel-Company
José María Montiel-Company
CBCarlos Bellot-Arcis
Carlos Bellot-Arcis
JFJOSE FELIX MAÑES FERRER
JOSE FELIX MAÑES FERRER
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
A systematic review and meta-analysis was performed to analyze the survival of onlay restorations in the posterior region, their clinical behavior according to the material used (ceramic reinforced with lithium disilicate, conventional feldspathic ceramic or reinforced with leucite; hybrid materials and composite), possible complications, and the factors influencing restoration success. The systematic review was based on the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement, without publication date or language restrictions. An electronic search was made in the PubMed, Scopus, Embase, and Cochrane databases. After discarding duplicate publications and studies that failed to meet the inclusion criteria, the articles were selected based on the population, intervention, comparison, outcome (PICO) question. The following variables were considered in the qualitative and quantitative analyses: restoration survival rate (determined by several clinical parameters), the influence of the material used upon the clinical behavior of the restorations, and the complications recorded over follow-up. A total of 29 articles were selected for the qualitative analysis and 27 for the quantitative analysis. The estimated restoration survival rate was 94.2%. The predictors of survival were the duration of follow-up (beta = −0.001; p = 0.001) and the onlay material used (beta = −0.064; p = 0.028). Composite onlays were associated with a lower survival rate over time. Onlays are a good, conservative, and predictable option for restoring dental defects in the posterior region, with a survival rate of over 90%. The survival rate decreases over time and with the use of composite as onlay material.

9 November 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AAAmaia Amesti
Amaia Amesti
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
BVBlanca Verdejo-Solá
Blanca Verdejo-Solá
AFAntonio Fons-Font
Antonio Fons-Font
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
Background: The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. Materials and methods: This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health (PubMed), Scopus, Web of Science (WOS), and Embase. In vitro trials published during the last 10 years were included in the review. Results: Applying inclusion criteria based on the review’s population, intervention, comparison, outcome (PICO) question, 13 articles were selected. Meta-analysis by restoration type estimated the fracture resistance of inlays to be 1923.45 Newtons (N); of onlays 1644 N and of overlays 1383.6 N. Meta-analysis by restoration material obtained an estimated fracture resistance for ceramic of 1529.5 N, for composite resin of 1600 Ne, for resin nanoceramic 2478.7 N, and hybrid ceramic 2108 N. Conclusions: Resin nanoceramic inlays present significantly higher fracture resistance values. Proximal box elevation does not exert any influence on the fracture resistance of indirect restorations.


24 March 2021 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
JHJavier Molina Hernandez
Javier Molina Hernandez
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
Javier MonteroJavier Montero
Javier Montero
LGLorena González-García
Lorena González-García
Background: The main aim of the present study was to examine the relationships among work environment, job satisfaction and burnout in dentists and to analyse the way in which certain sociodemographic variables, such as gender, professional experience and weekly working hours, predict the perception of the work environment. Methods: A battery of online questionnaires was sent to 3876 dentists officially registered in the triple-province region of Valencia; the battery included the Survey of Organizational Attributes for Dental Care, the Warr–Cook–Wall Overall Job Satisfaction Scale, the Maslach Burnout Inventory and a series of sociodemographic questions formulated for the specific purpose of this study. To assess the relations with the independent variables, we calculated the Pearson correlation coefficient, the Z-scores were calculated to make effect sizes comparable, and the associations between the scales and the sociodemographic variables were investigated by adjusted multiple regression analysis. Results: A total of 336 participants (9.4%) correctly completed the survey in this study. The mean (M) age was 37.6 years old (standard deviation (SD) = 9.6, median (Me) = 34). Participants reported high scores on the work environment and job satisfaction scales, with only limited experiences of burnout (3.8%). Work environment and burnout were significantly and positively predicted by years of professional experience (β = .078; p = .000 and β = .107; p = .004, respectively), and job satisfaction was significantly and positively predicted by weekly hours of work (β = .022; p = .001), without significant differences according to gender. Conclusions: Dentists who work over 20 hours a week and have more years of professional experience report having better perceptions of well-being at work, with no significant difference according to gender. It is important to highlight the aspects that improve well-being in dentistry to reduce burnout, which would lead to greater work engagement and better attention to patients.

Verified
Journal Article
Open access
PDF file
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
AMAlejandra Baima Moscardó
Alejandra Baima Moscardó
ESEduardo José Selva-Otaolaurruchi
Eduardo José Selva-Otaolaurruchi
JMJosé María Montiel-Company
José María Montiel-Company
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
Background: The aim of this systematic review and meta-analysis was to determine the wear sustained in the natural antagonist tooth in cases of full-coverage fixed-base prosthetic restorations or monolithic zirconia tooth-supported crowns, as well as to determine the wear in the restoration itself, both in the short- and medium-term and considering the factors that may influence wear. Material and methods: A systematic literature review and meta-analysis, based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated wear in antagonist teeth in relation to fixed-prosthesis monolithic zirconia crowns. A total of 5 databases were consulted in the literature search: Pubmed-Medline, Cochrane, Scopus, Embase and Web of Science (WOS). After eliminating duplicated articles and applying the inclusion criteria, eight articles were selected for the qualitative analysis and four for the quantitative analysis. Results: Mean maximum wear of the antagonist tooth in relation to monolithic zirconia crowns of magnitude 95.45 µm (CI at 95% 79.57–111.33) was observed. By using a meta-regression model (R2 = 0.92) the significant effect of time in maximum wear rate (p < 0.001) was observed, estimated at 6.13 µm per month (CI at 95% 3.99–8.27). Furthermore, monolithic zirconia crowns are subject to a mean maximum wear of 58.47 µm (CI 95% 45.44–71.50). By using a meta-regression model (R2 = 0.53) the significant effect of time in the maximum wear value was observed (p = 0.053), estimated at 3.40 µm per month (CI al 95% −0.05–6.85). Conclusions: Monolithic zirconia crowns lead to a progressive maximum wear of the antagonist tooth over time which is greater than the maximum wear sustained in the crown itself. It is not possible to establish an objective and quantitative objection in relation to natural enamel wear or metal–ceramic crowns.

12 October 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AAAndrea Torres Alemany
Andrea Torres Alemany
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
JMJosé María Montiel-Company
José María Montiel-Company
CLCarlos Labaig-Rueda
Carlos Labaig-Rueda
JMJose Mañes
Jose Mañes
Short implants are an increasingly common alternative to other surgical techniques in areas where bone availability is reduced. Despite the advantages they offer, a variety of biological repercussions have been described in the literature that can even lead to the loss of these. The aim of this systematic review and meta-analysis was to analyze the impact of the use of short implants on their survival and on peri-implant bone loss, evaluating the influence that length, diameter, and crown-to-implant ratio (C/I) have on these parameters. This systematic review was based on guidelines proposed by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). An electronic search was conducted using terms related to the use of short implants in partially or totally edentulous patients. A total of five databases were consulted in the literature search: PubMed, Embase, Cochrane, Scopus, and Web of Science. After eliminating the duplicate articles and assessing which ones met the inclusion criteria, 15 articles were included for the qualitative analysis and 14 for the quantitative study. Through meta-analysis, the percentage of implant loss and peri-implant bone loss was estimated. Relating these parameters to length, diameter, and C/I ratio, no significant differences have been found for implant loss (values of p = 0.06, 0.10, and 0.9, respectively for length, diameter, and C/I ratio), nor for peri-implant bone loss (values of p = 0.71, 0.72, and 0.36, respectively for length, diameter, and C/I ratio). In conclusion, the use of short implants does not seem to have a significant influence on marginal bone loss or the survival rate of implants.