John Paul Ortiz Bustillo

Mr. John Paul Ortiz Bustillo

Center for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia
+1
orcid
PhD (Medical Radiation Physics) Candidate

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
TBThomas Breslin
Thomas Breslin
JPJason Paino
Jason Paino
MWMarie Wegner
Marie Wegner
EEElette Engels
Elette Engels
SFStefan Fiedler
Stefan Fiedler
ESElisabeth Schültke
Elisabeth Schültke
The production of anthropomorphic phantoms generated from tissue-equivalent materials is challenging but offers an excellent copy of the typical environment encountered in typical patients. High-quality dosimetry measurements and the correlation of the measured dose with the biological effects elicited by it are a prerequisite in preparation of clinical trials with novel radiotherapy approaches. We designed and produced a partial upper arm phantom from tissue-equivalent materials for use in experimental high-dose-rate radiotherapy. The phantom was compared to original patient data using density values and Hounsfield units obtained from CT scans. Dose simulations were conducted for broad-beam irradiation and microbeam radiotherapy (MRT) and compared to values measured in a synchrotron radiation experiment. Finally, we validated the phantom in a pilot experiment with human primary melanoma cells.

30 May 2018
Verified
Book Chapter
Closed access
PDF file
JBJohn Paul Ortiz Bustillo
John Paul Ortiz Bustillo
RTRoy Tumlos
Roy Tumlos
RRRandal Zandro Remoto
Randal Zandro Remoto

4 July 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
JBJohn Paul Ortiz Bustillo
John Paul Ortiz Bustillo
JPJason Paino
Jason Paino
MBMicah Barnes
Micah Barnes
JCJames Cayley
James Cayley
VRVincent de Rover
Vincent de Rover
MLMichael Lerch
Michael Lerch
Objective. This study aims to design, manufacture, and test 3D printed quality assurance (QA) dosimetry phantoms for synchrotron brain cancer radiation therapy at the Australian synchrotron. Approach. Fabricated 3D printed phantoms from simple slab phantoms, a preclinical rat phantom, and an anthropomorphic head phantom were fabricated and characterized. Attenuation measurements of various polymers, ceramics and metals were acquired using synchrotron monochromatic micro-computed tomography (CT) imaging. Polylactic acid plus, VeroClear, Durable resin, and tricalcium phosphate were used in constructing the phantoms. Furthermore, 3D printed bone equivalent materials were compared relative to ICRU bone and hemihydrate plaster. Homogeneous and heterogeneous rat phantoms were designed and fabricated using tissue-equivalent materials. Geometric accuracy, CT imaging, and consistency were considered. Moreover, synchrotron broad-beam x-rays were delivered using a 3 Tesla superconducting multipole wiggler field for four sets of synchrotron radiation beam qualities. Dose measurements were acquired using a PinPoint ionization chamber and compared relative to a water phantom and a RMI457 Solid Water phantom. Experimental depth doses were compared relative to calculated doses using a Geant4 Monte Carlo simulation. Main results. Polylactic acid (PLA+) shows to have a good match with the attenuation coefficient of ICRU water, while both tricalcium phosphate and hydroxyapatite have good attenuation similarity with ICRU bone cortical. PLA+ material can be used as substitute to RMI457 slabs for reference dosimetry with a maximum difference of 1.84%. Percent depth dose measurement also shows that PLA+ has the best match with water and RMI457 within ±2.2% and ±1.6%, respectively. Overall, PLA+ phantoms match with RMI457 phantoms within ±3%. Significance and conclusion. The fabricated phantoms are excellent tissue equivalent equipment for synchrotron radiation dosimetry QA measurement. Both the rat and the anthropomorphic head phantoms are useful in synchrotron brain cancer radiotherapy dosimetry, experiments, and future clinical translation of synchrotron radiotherapy and imaging.

30 May 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
JBJohn Paul Ortiz Bustillo
John Paul Ortiz Bustillo
JPJason Paino
Jason Paino
MBMicah Barnes
Micah Barnes
MCMatthew Cameron
Matthew Cameron
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
MLMichael Lerch
Michael Lerch
Objective. This study aims to characterize radiological properties of selected additive manufacturing (AM) materials utilizing both material extrusion and vat photopolymerization technologies. Monochromatic synchrotron x-ray images and synchrotron treatment beam dosimetry were acquired at the hutch 3B and 2B of the Australian Synchrotron-Imaging and Medical Beamline. Approach. Eight energies from 30 keV up to 65 keV were used to acquire the attenuation coefficients of the AM materials. Comparison of theoretical, and experimental attenuation data of AM materials and standard solid water for MV linac was performed. Broad-beam dosimetry experiment through attenuated dose measurement and a Geant4 Monte Carlo simulation were done for the studied materials to investigate its attenuation properties specific for a 4 tesla wiggler field with varying synchrotron radiation beam qualities. Main results. Polylactic acid (PLA) plus matches attenuation coefficients of both soft tissue and brain tissue, while acrylonitrile butadiene styrene, Acrylonitrile styrene acrylate, and Draft resin have close equivalence to adipose tissue. Lastly, PLA, co-polyester plus, thermoplastic polyurethane, and White resins are promising substitute materials for breast tissue. For broad-beam experiment and simulation, many of the studied materials were able to simulate RMI457 Solid Water and bolus within ±10% for the three synchrotron beam qualities. These results are useful in fabricating phantoms for synchrotron and other related medical radiation applications such as orthovoltage treatments. Significance and conclusion. These 3D printing materials were studied as potential substitutes for selected tissues such as breast tissue, adipose tissue, soft-tissue, and brain tissue useful in fabricating 3D printed phantoms for synchrotron imaging, therapy, and orthovoltage applications. Fabricating customizable heterogeneous anthropomorphic phantoms (e.g. breast, head, thorax) and pre-clinical animal phantoms (e.g. rodents, canine) for synchrotron imaging and radiotherapy using AM can be done based on the results of this study.

22 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JBJohn Paul Ortiz Bustillo
John Paul Ortiz Bustillo
EEElette E.M. Engels
Elette E.M. Engels
VRVincent de Rover
Vincent de Rover
KRKiarn Roughley
Kiarn Roughley
JPJulia Rebecca D. Posadas
Julia Rebecca D. Posadas
MLMichael L.F. Lerch
Michael L.F. Lerch
Synchrotron microbeam radiotherapy (MRT) is an innovative cancer treatment that uses micron-sized of ultra-high dose rate spatially fractionated X-rays to effectively control cancer growth while reducing the damage to surrounding healthy tissue. However, the current pre-clinical experiments are commonly limited with the use of conventional two-dimensional cell cultures which cannot accurately model in vivo tissue environment. This study aims to propose a three-dimensional (3D) bioprinting gelatin methacryloyl (GelMA) hydrogel protocol and to characterize 3D bioprinted glioma relative to cell monolayer and spheroid models for experimental MRT using 9L rat gliosarcoma and U87 human glioma. Synchrotron broad-beam (SBB) and MRT beams were delivered to all cell models using 5, 10, and 20 Gy. 3D bioprinting enables the creation of 3D cell models that mimic in vivo conditions using bioinks, biomaterials, and cells. Synchrotron dosimetry, Monte Carlo simulation, in vitro cell viability, and fluorescence microscopy were performed to understand the relationship of the radiation dosimetry with the radiobiological response of different cancer models. Encapsulated gliomas were placed inside 3D printed human and rat phantoms to mimic scattering conditions. Results showed that MRT kills more gliomas relative to SBB for all cell models. The 3D bioprinted culture detected the spatial clustering of dead cells due to MRT high peak doses as seen in fluorescence imaging. The result of this study progresses MRT research by integrating 3D bioprinting techniques in radiobiological experiments. The study’s bioprinting protocol and results will help in reducing the use of animal experiments and possibly in clinical translation of MRT.

20 January 2025 in Physica Medica
Verified
Journal Article
Open access
JBJohn Paul Ortiz Bustillo
John Paul Ortiz Bustillo
JMJacob L. Mata
Jacob L. Mata
JPJulia Rebecca D. Posadas
Julia Rebecca D. Posadas
EIElrick T. Inocencio
Elrick T. Inocencio
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
MLMichael L.F. Lerch
Michael L.F. Lerch
To propose comprehensive characterization methods of additive manufacturing (AM) materials for MV photon and MeV electron radiotherapy. This study investigated 15 AM materials using CT machines. Geometrical accuracy, tissue-equivalence, uniformity, and fabrication parameters were considered. Selected soft tissue equivalent filaments were used to fabricate slab phantoms and compared with water equivalent RW3 phantom by delivering planar 6 & 10 MV photons and 6, 9, 12, 15, & 18 MeV electrons. Finally, a 3D printed CT-Electron Density characterization phantom was fabricated. Materials used to print test objects can simulate tissues from adipose (relative electron density, ρe=0.72) up to near inner bone-equivalent (ρe=1.08). Lower densities such as breast and lung can be simulated using infills from 90 % down to 30 %, respectively. The gyroid infill pattern shows the lowest CT number variation and is recommended for low infill percentage printing. CT number uniformity can be observed from 40 % up to 100 % infill, while printing orientation does not significantly affect the CT number. The measured doses using the 3D printed phantoms show to have good agreement with TPS calculated dose for photon (< 1 % difference) and electron (< 5 % difference). Varying the printed slab thicknesses shows very similar response (< 3 % difference) compared with RW3 slabs except for 6 MeV electrons. Lastly, the fabricated CT-ED phantom generally matches the lung- up to the soft tissue- equivalence. The proposed methods give the outline for characterization of AM materials as tissue-equivalent substitute. Printing parameters affect the radiological quality of 3D-printed object.