Maik Bertke

Mr. Maik Bertke

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2017 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
MBMaik Bertke
Maik Bertke
GHGerry Hamdana
Gerry Hamdana
WWWenze Wu
Wenze Wu
HWHutomo Suryo Wasisto
Hutomo Suryo Wasisto
EUErik Uhde
Erik Uhde
Erwin PeinerErwin Peiner
Erwin Peiner
In this paper, the asymmetric resonance frequency ( f 0 ) responses of thermally in-plane excited silicon cantilevers for a pocket-sized, can tilever-based airborne nanoparticle detec tor (Cantor) are analysed. By measuring the shift of f 0 caused by the deposition of nanoparticles (NPs), the cantilevers are used as a microbalance. The cantilever sensors are low cost manufactured from silicon by bulk-micromachining techniques and contain an integrated p- type heating actuator and a sensing piezoresistive Wheatstone bridge. f 0 is tracked by a homemade phase-locked loop (PPL) for real-time measurements. To optimize the sensor performance, a new cantilever geometry was designed, fabricated and characterized by its frequency responses. The most significant characterisation parameters of our application are f 0 and the quality factor ( Q ), which have high influences on sensitivity and efficiency of the NP detector. Regarding the asymmetric resonance signal, a novel fitting function based on the Fano resonance replacing the conventionally used function of the simple harmonic oscillator and a method to calculate Q by its fitting parameters were developed for a quantitative evaluation. To obtain a better understanding of the resonance behaviours, we analysed the origin of the asymmetric line shapes. Therefore, we compared the frequency response of the on-chip thermal excitation with an external excitation using an in-plane piezo actuator. In correspondence to the Fano effect, we could reconstruct the measured resonance curves by coupling two signals with constant amplitude and the expected signal of the cantilever, respectively. Moreover, the phase of the measurement signal can be analysed by this method, which is important to understand the locking process of the PLL circuit. Besides the frequency analysis, experimental results and calibration measurements with different particle types are presented. Using the described analysis method, decent results to optimize a next generation of Cantor are expected.

21 February 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
JTJavier Toledo
Javier Toledo
VRVictor Ruiz-Díez
Victor Ruiz-Díez
MBMaik Bertke
Maik Bertke
HWHutomo Suryo Wasisto
Hutomo Suryo Wasisto
Erwin PeinerErwin Peiner
Erwin Peiner
Jose-luis Sanchez-RojasJose-luis Sanchez-Rojas
Jose-luis Sanchez-Rojas
In this work, we demonstrate the potential of a piezoelectric resonator for developing a low-cost sensor system to detect microscopic particles in real-time, which can be present in a wide variety of environments and workplaces. The sensor working principle is based on the resonance frequency shift caused by particles collected on the resonator surface. To test the sensor sensitivity obtained from mass-loading effects, an Aluminum Nitride-based piezoelectric resonator was exposed to cigarette particles in a sealed chamber. In order to determine the resonance parameters of interest, an interface circuit was implemented and included within both open-loop and closed-loop schemes for comparison. The system was capable of tracking the resonance frequency with a mass sensitivity of 8.8 Hz/ng. Although the tests shown here were proven by collecting particles from a cigarette, the results obtained in this application may have interest and can be extended towards other applications, such as monitoring of nanoparticles in a workplace environment.

22 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ASAndi Setiono
Andi Setiono
MBMaik Bertke
Maik Bertke
Wilson Ombati Nyang'auWilson Ombati Nyang'au
Wilson Ombati Nyang'au
JXJiushuai Xu
Jiushuai Xu
MFMichael Fahrbach
Michael Fahrbach
Erwin PeinerErwin Peiner
Erwin Peiner
In this study, we investigate the performance of two piezoresistive micro-electro-mechanical system (MEMS)-based silicon cantilever sensors for measuring target analytes (i.e., ultrafine particulate matters). We use two different types of cantilevers with geometric dimensions of 1000 × 170 × 19.5 µm3 and 300 × 100 × 4 µm3, which refer to the 1st and 2nd types of cantilevers, respectively. For the first case, the cantilever is configured to detect the fundamental in-plane bending mode and is actuated using a resistive heater. Similarly, the second type of cantilever sensor is actuated using a meandering resistive heater (bimorph) and is designed for out-of-plane operation. We have successfully employed these two cantilevers to measure and monitor the changes of mass concentration of carbon nanoparticles in air, provided by atomizing suspensions of these nanoparticles into a sealed chamber, ranging from 0 to several tens of µg/m3 and oversize distributions from ~10 nm to ~350 nm. Here, we deploy both types of cantilever sensors and operate them simultaneously with a standard laboratory system (Fast Mobility Particle Sizer, FMPS, TSI 3091) as a reference.

3 January 2019 in Chemosensors
Verified
Journal Article
Open access
PDF file
ASAndi Setiono
Andi Setiono
JXJiushuai Xu
Jiushuai Xu
MFMichael Fahrbach
Michael Fahrbach
MBMaik Bertke
Maik Bertke
Wilson Ombati Nyang'auWilson Ombati Nyang'au
Wilson Ombati Nyang'au
Erwin PeinerErwin Peiner
Erwin Peiner
The asymmetric resonance response in electro-thermal piezoresistive cantilever resonators causes a need of an optimization treatment for taking parasitic actuation-sensing effects into account. An electronic reference circuit for signal subtraction, integrated with the cantilever resonator has the capability to reduce the effect of parasitic coupling. Measurement results demonstrated that a symmetric amplitude shape (Lorentzian) and an optimized phase characteristic (i.e., monotonically decreasing) were successfully extracted from an asymmetric resonance response. With the monotonic phase response, real-time frequency tracking can be easier to implement using a phase-locked loop (PLL) system. In this work, an electro-thermal piezoresistive cantilever resonator functionalized with self-assembled monolayers of chitosan-covered ZnO nanorod arrays as sensitive layers has been investigated under different relative humidity (rH) levels. Enhancement of resonance phase response has been demonstrated by implementing the reference signal subtraction. Subsequently, a lock-in amplifier integrated with PLL system (MFLI, Zurich Instruments, Zurich, Switzerland) was then employed for continuously tracking the resonant frequency. As a result, we find a good correlation of frequency shift (∆f0) with change in rH monitored using a commercial reference sensor.

16 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
JXJiushuai Xu
Jiushuai Xu
MBMaik Bertke
Maik Bertke
AGAlaaeldin Gad
Alaaeldin Gad
FYFeng Yu
Feng Yu
GHGerry Hamdana
Gerry Hamdana
Erwin PeinerErwin Peiner
Erwin Peiner
In this study, a ZnO nanorods (NRs) patterned MEMS piezoresistive silicon micro-cantilever was fabricated as environmental monitor. The fabrication starts from bulk silicon, utilizing photolithography, diffusion, inductively coupled plasma (ICP) cryogenic dry etching, Zinc DC-sputtering, and chemical bath deposition (CBD) etc. This sensor shows a humidity sensitivity value of 6.35 ± 0.27 ppm/RH% at 25 °C in the range from 30% RH to 80% RH.

1 August 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
MBMaik Bertke
Maik Bertke
MFMichael Fahrbach
Michael Fahrbach
GHGerry Hamdana
Gerry Hamdana
JXJiushuai Xu
Jiushuai Xu
HWHutomo Suryo Wasisto
Hutomo Suryo Wasisto
Erwin PeinerErwin Peiner
Erwin Peiner