Time of Flight (ToF) Lidar range finder is widely used in various applications such as automotive driving, marine environment surveying, atmospheric observing, and physical distancing monitoring. The ToF Lidar offers a high-resolution range, which can be achieved by increasing the modulation frequency. However, when the modulation frequency is increased, the maximum unambiguous range tends to decrease. To overcome such a problem, we develop a novel ToF Lidar range finder based on dual-modulation frequencies switching, capable of providing an extended range while maintaining the high-resolution. In the design, the modulation frequency is alternately changed between 2 MHz and 10 MHz to modulate the intensity of the laser diode as a transmitter. We operate an avalanche photodetector as a receiver to obtain a reflection of modulated light from a target. By switching between dual-modulation frequencies, the photodetector detects two-phase shifts, which are calculated by our phase-shift algorithm. It is shown that the proposed algorithm can solve the ambiguous range problem. As proof of the concept, we experimentally demonstrate a range measurement of a target up to 55 m distance, where the ambiguous range is experienced four times if only a single modulation frequency of 10 MHz is used. Interestingly, the range ambiguity no longer appears after applying the proposed design and algorithm.
In this study, we investigate the performance of two piezoresistive micro-electro-mechanical system (MEMS)-based silicon cantilever sensors for measuring target analytes (i.e., ultrafine particulate matters). We use two different types of cantilevers with geometric dimensions of 1000 × 170 × 19.5 µm3 and 300 × 100 × 4 µm3, which refer to the 1st and 2nd types of cantilevers, respectively. For the first case, the cantilever is configured to detect the fundamental in-plane bending mode and is actuated using a resistive heater. Similarly, the second type of cantilever sensor is actuated using a meandering resistive heater (bimorph) and is designed for out-of-plane operation. We have successfully employed these two cantilevers to measure and monitor the changes of mass concentration of carbon nanoparticles in air, provided by atomizing suspensions of these nanoparticles into a sealed chamber, ranging from 0 to several tens of µg/m3 and oversize distributions from ~10 nm to ~350 nm. Here, we deploy both types of cantilever sensors and operate them simultaneously with a standard laboratory system (Fast Mobility Particle Sizer, FMPS, TSI 3091) as a reference.
The asymmetric resonance response in electro-thermal piezoresistive cantilever resonators causes a need of an optimization treatment for taking parasitic actuation-sensing effects into account. An electronic reference circuit for signal subtraction, integrated with the cantilever resonator has the capability to reduce the effect of parasitic coupling. Measurement results demonstrated that a symmetric amplitude shape (Lorentzian) and an optimized phase characteristic (i.e., monotonically decreasing) were successfully extracted from an asymmetric resonance response. With the monotonic phase response, real-time frequency tracking can be easier to implement using a phase-locked loop (PLL) system. In this work, an electro-thermal piezoresistive cantilever resonator functionalized with self-assembled monolayers of chitosan-covered ZnO nanorod arrays as sensitive layers has been investigated under different relative humidity (rH) levels. Enhancement of resonance phase response has been demonstrated by implementing the reference signal subtraction. Subsequently, a lock-in amplifier integrated with PLL system (MFLI, Zurich Instruments, Zurich, Switzerland) was then employed for continuously tracking the resonant frequency. As a result, we find a good correlation of frequency shift (∆f0) with change in rH monitored using a commercial reference sensor.
Cantilever-based sensors have attracted considerable attention in the recent past due to their enormous and endless potential and possibilities coupled with their dynamic and unprecedented sensitivity in sensing applications. In this paper, we present a technique that involves depositing and vaporizing (at ambient conditions) a particle-laden water droplet onto a defined sensing area on in-house fabricated and commercial-based silicon microcantilever sensors. This process entailed the optimization of dispensing pressure and time to generate and realize a small water droplet volume (Vd = 49.7 ± 1.9 pL). Moreover, we monitored the water evaporation trends on the sensing surface and observed total evaporation time per droplet of 39.0 ± 1.8 s against a theoretically determined value of about 37.14 s. By using monodispersed particles in water, i.e., magnetic polystyrene particles (MPS) and polymethyl methacrylate (PMMA), and adsorbing them on a dynamic cantilever sensor, the mass and number of these particles were measured and determined comparatively using resonant frequency response measurements and SEM particle count analysis, respectively. As a result, we observed and reported monolayer particles assembled on the sensor with the lowest MPS particles count of about 19 ± 2.
14 January 2019 in Journal of Sensors and Sensor Systems
The asymmetric resonance response in thermally actuated piezoresistive cantilever sensors causes a need for optimization, taking parasitic actuation–sensing effects into account. In this work, two compensation methods based on Wheatstone bridge (WB) input voltage (VWB_in) adjustment and reference circuit involvement were developed and investigated to diminish those unwanted coupling influences. In the first approach, VWB_in was increased, resulting in a higher current flowing through the WB piezoresistors as well as a temperature gradient reduction between the thermal actuator (heating resistor: HR) and the WB, which can consequently minimize the parasitic coupling. Nevertheless, increasing VWB_in (e.g., from 1 to 3.3 V) may also yield an unwanted increase in power consumption by more than 10 times. Therefore, a second compensation method was considered: i.e., a reference electronic circuit is integrated with the cantilever sensor. Here, an electronic reference circuit was developed, which mimics the frequency behavior of the parasitic coupling. By subtracting the output of this circuit from the output of the cantilever, the resonance response can thus be improved. Both simulated and measured data show optimized amplitude and phase characteristics around resonant frequencies of 190.17 and 202.32 kHz, respectively. With this phase optimization in place, a phase-locked-loop (PLL) based system can be used to track the resonant frequency in real time, even under changing conditions of temperature (T) and relative humidity (RH), respectively. Finally, it is expected to enhance the sensitivity of such piezoresistive electro-thermal cantilever sensors under loading with any target analytes (e.g., particulate matter, gas, and humidity).
7 November 2019 in Journal of Micromechanics and Microengineering
In this paper, fabrication and testing of a miniaturized microcantilever-based particulate matter detector with integrated electrostatic on-chip ultrafine particle (UFP) separation and collection are presented. Mass added to the sensor causes a resonance frequency shift. To attract naturally charged particles, the cantilever is equipped with a collection electrode. In addition, a µ -channel is integrated, to improve the particle collection efficiency and to enable a size/mass-related particle separation. For electrical read-out, piezo-resistive struts are attached to the cantilever sidewalls near its clamping. This design offers high miniaturization potential, since no integration of transducing electronics on the cantilever beam is needed. The sensors are fabricated using Si bulk material and standard micromachining technology; the cantilevers have a thickness of 3 ± 0.5 µ m, a width of 3.1 ± 0.3 µ m, 5.9 ± 0.4 µ m or 10.5 ± 0.4 µ m and a length of 118.7 ± 0.8 µ m, 168.8 ± 0.8 µ m or 171.2 ± 1 µ m, respectively. To this end, a front-side release process using cryogenic inductive-coupled plasma reactive ion etching was developed, which does not require additional sidewall passivation steps. Testing of the resonator function by operating the sensor inside a scanning electron microscope and reference measurements inside a temperature-controlled test chamber using synthetic carbon UFPs (~160 nm average mass concentration distribution) and a fast mobility particle sizer as a reference instrument were carried out. Here, the ability to detect low UFP mass concentrations in the range <10 µ g m −3 could be shown with a limit of detection of ~1 µ g m −3 and a collection time of ~10 min. In addition, a voltage dependence of the collection efficiency was found at constant UFP-concentration conditions, which is an indication of size-selective UFP collection.