Fu Guan

Dr. Fu Guan

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2025 in Circulation
Verified
Journal Article
Closed access
LCLiang Chen
Liang Chen
YHYuxiao Hu
Yuxiao Hu
ASArdan M. Saguner
Ardan M. Saguner
BBBarbara Bauce
Barbara Bauce
XZXian-Liang Zhou
Xian-Liang Zhou
SHShengshou Hu
Shengshou Hu
BACKGROUND: Genetic variants in desmosomal cadherins, desmoglein 2 ( DSG2 ) and desmocollin 2 ( DSC2 ), cause a distinct form of arrhythmogenic right ventricular cardiomyopathy (ARVC), which remains poorly reported. In this study, we aimed to provide a comprehensive description of the phenotypic expression, natural history, and clinical outcomes of patients with this ARVC subset. METHODS: Genetic and clinical data of DSG2 and DSC2 variant carriers were collected from 5 countries in Europe and Asia. We assessed the phenotypic profile of these patients and their clinical outcomes, focusing on heart failure and ventricular arrhythmia events. RESULTS: Overall, 271 subjects, 254 with DSG2 variants, were included in this study (median age, 38 years [interquartile range, 25–52]; 62.7% male). Of these, 165 were probands, and 200 were diagnosed with definite ARVC. A total of 181 (66.8%) individuals carried missense variants, mainly distributed in the extracellular domains. Notably, we included 78 (28.8%) individuals with multiple variants. Of the 200 cases with diagnosed ARVC, 41 (20.5%) experienced premature cardiac death before the age of 65. Among the 81 individuals for whom both left ventricular ejection fraction and right ventricular fractional area change data were available at presentation, 29 (35.8%) had isolated right ventricular dysfunction, and 16 (19.8%) had biventricular dysfunction. Single-variant carriers who engaged in intense physical exercise were younger at disease onset compared with those who did not ( P =0.001). Compared with single-variant carriers, those with multiple variants were more likely to be diagnosed with ARVC (96.2% versus 64.8%; P <0.001) and exhibited more severe left ventricular dysfunction (44.4% versus 22.1%; P =0.001) and right ventricular dilation (88.9% versus 55.8%, P <0.001). Multiple-variant carriers were significantly younger at ARVC diagnosis compared with single-variant carriers (33 [18–49] years versus 42 [27–54] years; P <0.001]. During follow-up, end-stage heart failure ( P <0.001) and malignant ventricular arrhythmias ( P =0.004) were significantly more frequent in multiple-variant compared with single-variant carriers. Compared with PKP2 patients, DSG2/DSC2 patients exhibited a significantly higher risk of end-stage heart failure ( P <0.001). CONCLUSIONS: ARVC attributable to variants in desmosomal cadherins mostly present with right ventricular or biventricular disease. Multiple variants are common in these patients and are associated with more frequent clinical penetrance, earlier onset of disease, and adverse clinical outcomes.

14 January 2021 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
FGFu Guan
Fu Guan
GLGuangping Li
Guangping Li
YLYong Liu
Yong Liu
XGXing Gao
Xing Gao
RZRui Zhou
Rui Zhou
Background: Pacemaker lead dislodgement may cause malfunction in the pacing system, which may lead to severe adverse events. For patients with sick sinus syndrome but normal atrioventricular conduction, atrial lead dislocation may cause excessive unnecessary ventricular pacing, resulting in nonphysiological pacing leading to heart failure. The longer the unwanted ventricular pacing continues, the greater the chances that irreversible heart failure may occur. Ironically, we admitted a patient who had been refusing dislodged lead relocation for 7 years. The symptoms of heart failure were significantly resolved after new atrial lead implantation. We reviewed her clinical data before and after the procedure and believed the case was worthy of reflection. Case presentation: An 83-year-old Han Chinese woman presented with heart failure symptoms for 7 years due to the late macro-dislodgement of an atrial pacing lead. Her echocardiogram showed average left ventricular ejection fraction (LVEF) but reduced left ventricular end-diastolic volume (LVEDV) during right ventricular pacing, indicating heart failure with preserved ejection fraction (HFpEF). After 7 years of refusal, she finally agreed to implantation of a new atrial lead. She has been doing well since the operation. Conclusions: For patients with sick sinus syndrome with dual-chamber pacemaker indication, atrial lead dislodgement should be appropriately managed if the atrioventricular function is normal. As the consequences are subtle and appear gradually, they might be overlooked by patients and even doctors. Implanting a new atrial lead is the right thing to do rather than just passively waiting or treating with symptom relief medications.

19 November 2021 in Medicine
Verified
Journal Article
Open access
FGFu Guan
Fu Guan
JPJianjun Peng
Jianjun Peng
SHShu Hou
Shu Hou
LRLihui Ren
Lihui Ren
YYYunan Yue
Yunan Yue
GLGuangping Li
Guangping Li
Very elderly people (over 80 years) with cardiac implantable electronic devices (CIEDs) indications often have a higher prevalence of aging comorbidity, among which cognitive impairment is not uncommon. This study aimed to investigate periprocedural complications of CIED implantation among very elderly patients with and without cognitive impairment. One hundred eighty patients ≥80 years of age indicated for CIED implantation were included in our study. During hospitalization, the cognitive evaluation was performed according to the Diagnostic and Statistical Manual of Mental Disorders (fifth edition). According to the cognitive test results, patients were divided into 2 groups (90 patients with normal cognitive function and 90 patients with cognitive impairment). Meanwhile, their physical parameters and laboratory measurements were completed. The procedural data and periprocedural complications were collected from both groups. The association between cognitive impairment and periprocedural complications was analyzed using univariate and multiple logistic regression analyses. During a one-month follow-up, the most frequent periprocedural complications in very elderly patients were pocket hematoma and thrombosis events. Cognitively impaired patients had a higher incidence of complications than normal cognitive patients. Multivariate regression analysis showed that cognitive impairment was positively correlated with periprocedural complications in very elderly patients. Cognitive impairment is associated with increased periprocedural complications of CIED implantation in very elderly patients.

4 July 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
NNNikolas Nozica
Nikolas Nozica
BABabken Asatryan
Babken Asatryan
SAStefania Aur
Stefania Aur
JBJudith Bouchardy
Judith Bouchardy
MSMarkus Schwerzmann
Markus Schwerzmann
LRLaurent Roten
Laurent Roten
Background: Data on the incidence of arrhythmias, associated cardiac interventions, and outcome in patients with dextro‐transposition of the great arteries and atrial switch are scarce. Methods and Results: In this multicenter analysis, we included adult patients with dextro‐transposition of the great arteries and atrial switch regularly followed up at 3 Swiss tertiary care hospitals. The primary outcome was a composite of left ventricular assist device, heart transplantation, and death. The secondary outcome was occurrence of ventricular tachycardia, ventricular fibrillation, or sudden cardiac death. We identified 207 patients (34% women; median age at last follow‐up, 35 years) with dextro‐transposition of the great arteries and atrial switch. Arrhythmias occurred in 97 patients (47%) at a median age of 22 years. A pacemaker or an implantable cardioverter‐defibrillator was implanted in 39 (19%) and 13 (6%) patients, respectively, and 33 (16%) patients underwent a total of 51 ablation procedures to target 60 intra‐atrial re‐entry tachycardias, 4 atrioventricular nodal re‐entry tachycardias, and 1 atrial fibrillation. The primary outcome occurred in 21 patients (10%), and the secondary outcome occurred in 18 patients (9%); both were more common in patients with concomitant ventricular septum defect than in those without (hazard ratio [HR], 3.06 [95% CI, 1.29–7.27], P =0.011; and HR, 3.62 [95% CI, 1.43–9.18], P =0.007, respectively). Conclusions: In patients with dextro‐transposition of the great arteries and atrial switch reaching adulthood, arrhythmias occur in almost half of patients, and associated rhythm interventions are frequent. One‐tenth of those patients do not survive until the age of 35 years free from left ventricular assist device or heart transplantation, and the outcome is worse in patients with concomitant ventricular septum defect.

Verified
Journal Article
Open access
PDF file
FGFu Guan
Fu Guan
MGMatthias Gass
Matthias Gass
FBFlorian Berger
Florian Berger
DADeniz Akdis
Deniz Akdis
FDFirat Duru
Firat Duru
TWThomas Wolber
Thomas Wolber
Aims: The widespread use of three-dimensional (3D) mapping systems and echocardiography in the field of cardiac electrophysiology has made it possible to perform transseptal punctures (TSP) with low or no fluoroscopy. However, such attempts in adults with congenital heart disease (ACHD) who have previously undergone surgical or interventional treatment are limited. Therefore, we sought to explore the feasibility and safety of an approach to perform zero- or low-fluoroscopy TSP in ACHD patients undergoing left atrial cardiac ablation procedures. Methods and results: This study included 45 ACHD patients who underwent TSP for ablation of left-sided tachycardias (left atrium or pulmonary venous atrium). Computed tomography (CT) of the heart was performed in all patients prior to ablation. 3D mapping of the right-sided heart chambers before TSP was used to superimpose the registered anatomy, which was subsequently used for the mapping-guided TSP technique. TSP was performed with zero-fluoroscopy in 27 patients, and the remaining 18 patients had a mean fluoroscopy exposure of 315.88 ± 598.43 μGy.m2 and a mean fluoroscopy duration of 1.9 ± 5.4 min. No patient in this cohort experienced TSP-related complications. Conclusion: Our study describes a fluoroscopy-free or low-dose fluoroscopy approach for TSP in ACHD patients undergoing catheter ablation of left-sided tachyarrhythmias who had been previously treated surgically or interventionally due to congenital heart defects. By superimposing 3D electroanatomic mapping with cardiac CT anatomy, this protocol proved to be highly effective, feasible and safe.

5 June 2022 in HeartRhythm Case Reports
Verified
Journal Article
Open access
FGFu Guan
Fu Guan
BSBarbara E. Stähli
Barbara E. Stähli
PJPhilipp Jakob
Philipp Jakob
TWThomas Wolber
Thomas Wolber