Andreas Weltin

Dr. Andreas Weltin

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
AWAndreas Weltin
Andreas Weltin
KSKinga Slotwinski
Kinga Slotwinski
Jochen KieningerJochen Kieninger
Jochen Kieninger
IMIsabella Moser
Isabella Moser
GJGerhard Jobst
Gerhard Jobst
GUGerald A. Urban
Gerald A. Urban
We present a novel, multiparametric microphysiometry system for the dynamic online monitoring of human cancer cell metabolism. The optically transparent, modular, hybrid microsystem is based on a glass chip and combines a cell cultivation chamber, microfluidics and metabolic monitoring with fully integrated chemo- and biosensors. pH and oxygen are measured in the cell culture area, and biosensors for lactate and glucose are connected downstream by microfluidics. The wafer-level fabrication features thin-film platinum and iridium oxide microelectrodes on a glass chip, microfluidics in an epoxy resist, a hybrid assembly and an on-chip reference electrode. The reliable analytical performance of the sensors in cell culture medium was demonstrated. The pH sensors exhibit a long-term stable, linear response. The oxygen sensors show a linear behaviour, which is also observed for low oxygen concentrations. Glucose and lactate measurements show a linear, long-term stable, selective and reversible behaviour in the desired range. T98G human brain cancer cells were cultivated and cell culture metabolism was measured on-chip. Stop/flow cycles were applied and extracellular acidification, respiration, glucose consumption and lactate production were quantified. Long-term metabolic rates were determined and all parameters could be measured in the outlet channel. A placement downstream of the cell cultivation area for biosensors was realised. A highly effective medium exchange and undiluted sampling from the cell culture chamber with low flow rates (2 μl min−1) and low volumes (15 μl per cycle) were achieved. The drug screening application was demonstrated by detecting alteration and recovery effects of cellular metabolism induced by the addition of substances to the medium.

5 April 2018 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
Jochen KieningerJochen Kieninger
Jochen Kieninger
AWAndreas Weltin
Andreas Weltin
HFHubert Flamm
Hubert Flamm
GUGerald A. Urban
Gerald A. Urban
We discuss microsensors for cell culture monitoring from 2D culture to organ-on-chip systems, including sensor principles, fabrication and culture formats.

1 December 2021 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JDJohannes Dornhof
Johannes Dornhof
Jochen KieningerJochen Kieninger
Jochen Kieninger
HMHarshini Muralidharan
Harshini Muralidharan
JMJochen Maurer
Jochen Maurer
GUGerald A. Urban
Gerald A. Urban
AWAndreas Weltin
Andreas Weltin
An organ-on-chip platform equipped with microsensors for long-term microfluidic cultivation and metabolic monitoring (O 2 , Glu, Lac) of 3D tumour organoid cultures grown from patient-derived single cancer stem cells.

1 November 2014 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
AWAndreas Weltin
Andreas Weltin
Jochen KieningerJochen Kieninger
Jochen Kieninger
BEBarbara Enderle
Barbara Enderle
AGAnne-Kathrin Gellner
Anne-Kathrin Gellner
BFBrita Fritsch
Brita Fritsch
GUGerald A. Urban
Gerald A. Urban

1 January 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
AWAndreas Weltin
Andreas Weltin
SHSteffen Hammer
Steffen Hammer
FNFozia Noor
Fozia Noor
YKYeda Kaminski
Yeda Kaminski
Jochen KieningerJochen Kieninger
Jochen Kieninger
GUGerald A. Urban
Gerald A. Urban

2 March 2016 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
AWAndreas Weltin
Andreas Weltin
Jochen KieningerJochen Kieninger
Jochen Kieninger
GUGerald A. Urban
Gerald A. Urban

Abstract

Miniaturized electrochemical in vivo biosensors allow the measurement of fast extracellular dynamics of neurotransmitter and energy metabolism directly in the tissue. Enzyme-based amperometric biosensing is characterized by high specificity and precision as well as high spatial and temporal resolution. Aside from glucose monitoring, many systems have been introduced mainly for application in the central nervous system in animal models. We compare the microsensor principle with other methods applied in biomedical research to show advantages and drawbacks. Electrochemical sensor systems are easily miniaturized and fabricated by microtechnology processes. We review different microfabrication approaches for in vivo sensor platforms, ranging from simple modified wires and fibres to fully microfabricated systems on silicon, ceramic or polymer substrates. The various immobilization methods for the enzyme such as chemical cross-linking and entrapment in polymer membranes are discussed. The resulting sensor performance is compared in detail. We also examine different concepts to reject interfering substances by additional membranes, aspects of instrumentation and biocompatibility. Practical considerations are elaborated, and conclusions for future developments are presented.

ᅟ