Johannes Dornhof

Johannes Dornhof

Auto-generated profile, based on publicly available information

Johannes Dornhof

Laboratory for Electrical Instrumentation and Embedded Systems, IMTEK – Department of Microsystems Engineering, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JDJohannes Dornhof
Johannes Dornhof
Jochen KieningerJochen Kieninger
Jochen Kieninger
HMHarshini Muralidharan
Harshini Muralidharan
JMJochen Maurer
Jochen Maurer
GUGerald A. Urban
Gerald A. Urban
AWAndreas Weltin
Andreas Weltin
An organ-on-chip platform equipped with microsensors for long-term microfluidic cultivation and metabolic monitoring (O 2 , Glu, Lac) of 3D tumour organoid cultures grown from patient-derived single cancer stem cells.

10 October 2022 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JDJohannes Dornhof
Johannes Dornhof
VZViktoria Zieger
Viktoria Zieger
Jochen KieningerJochen Kieninger
Jochen Kieninger
DFDaniel Frejek
Daniel Frejek
RZRoland Zengerle
Roland Zengerle
AWAndreas Weltin
Andreas Weltin
Three-dimensional (3D) cell agglomerates, such as microtissues, organoids, and spheroids, become increasingly relevant in biomedicine. They can provide in vitro models that recapitulate functions of the original tissue in the body and have applications in cancer research. For example, they are widely used in organ-on-chip systems. Microsensors can provide essential real-time information on cell metabolism as well as the reliability and quality of culture conditions. The combination of sensors and 3D cell cultures, especially single spheroids, is challenging in terms of reproducible formation, manipulation, and access to spheroids, precise positioning near sensors, and high cell-to-volume ratios to obtain meaningful biosignals in the most parallel approach possible. To overcome this challenge, we combined state-of-the-art bioprinting techniques to automatically print tumour spheroids directly into microwells of a chip-based electrochemical oxygen sensor array. We demonstrated highly accurate and reproducible spheroid formation (diameter of approx. 200 μm) and a spheroid deposition precision of 25 μm within a volume of 22 nl per droplet. Microstructures and hydrogel-coated microwells allowed the placement of single MCF-7 breast cancer spheroids close to the sensor electrodes. The microelectrode wells were sealed for oxygen measurements within a 55 nl volume for fast concentration changes. Accurate and stable amperometric oxygen sensor performance was demonstrated from atmospheric to anoxic regions. Cellular respiration rates from single tumour spheroids in the range of 450–850 fmol min−1 were determined, and alterations of cell metabolism upon drug exposure were shown. Our results uniquely combine bioprinting with 3D cell culture monitoring and demonstrate the much-needed effort for facilitation, parallelization, sensor integration, and drug delivery in 3D cell culture and organ-on-chip experiments. The workflow has a high degree of automation and potential for scalability. In order to achieve greater flexibility in the automation of spheroid formation and trapping, we employed a method based on drop-on-demand liquid handling systems, instead of the typical on-chip approach commonly used in microfluidics. Its relevance ranges from fundamental metabolic research over standardization of cell culture experiments and toxicological studies, to personalized medicine, e.g. patient-specific chemotherapy.

8 January 2025 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JDJohannes Dornhof
Johannes Dornhof
Jochen KieningerJochen Kieninger
Jochen Kieninger
SRStefan J. Rupitsch
Stefan J. Rupitsch
AWAndreas Weltin
Andreas Weltin
Cell cultures, organs-on-chip and microphysiological systems become increasingly relevant as in vitro models, e.g., in drug development, disease modelling, toxicology or cancer research. It has been underlined repeatedly that culture conditions and metabolic cues have a strong or even essential influence on the reproducibility and validity of such experiments but are often not appropriately measured or controlled. Here we review microsensor systems for cell metabolism for the continuous measurement of culture conditions in microfluidic and lab-on-chip platforms. We identify building blocks, features and essential advantages to underline the relevance of these systems and to derive appropriate requirements for development and practical use. We discuss different formats and geometries of cell culture, microfluidics and the resulting consequences for sensor placement, as the prerequisite for understanding the various approaches and classification of the systems. The major chemical and biosensors based on electrochemical and optical principles are discussed for general understanding and to contextualize current developments. We then review selected recent sensor systems with real-world implementations of sensing in cell cultures and organs-on-chip, employing a helpful characterization. That includes formats and cell models, microfluidic systems and sensor types applied in static and dynamic monitoring of 2D and 3D cell cultures, as well as single spheroids. We discuss notable advances, particularly with respect to sensor performance and the demonstration of long-term continuous measurements. We outline current approaches to system fabrication technologies, material choice, and interfacing, and comment on recent trends. Finally, we conclude with critical remarks on the current state of sensors in cell culture monitoring and identify avenues for future improvements for both developers and users of such systems, which will lead to better and more predictive in vitro models.

1 June 2019
Verified
Conference Paper
Closed access
JDJohannes Dornhof
Johannes Dornhof
Jochen KieningerJochen Kieninger
Jochen Kieninger
Jochen MaurerJochen Maurer
Jochen Maurer
GUGerald A. Urban
Gerald A. Urban
AWAndreas Weltin
Andreas Weltin
In vitro replica of 3D heterogeneous tumor systems are essential models on the path towards personalized chemotherapy in cancer research. Here, we present an organ-on-chip platform with integrated microelectrodes enabling online-monitoring of culture conditions and metabolic parameters of patient-derived, triple-negative breast cancer stem cells. Tumor organoids grow in compartments separated by microfluidic channels, permitting the generation of oxygen and drug gradients as seen in real tumors. Besides the electrochemical analysis, e.g. for oxygen or lactate, the transparent chip also allows characterization with optical methods. Such in situ monitoring systems bear a high potential for replacing animal models in drug research.

7 August 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
JDJohannes Dornhof
Johannes Dornhof
GUGerald A. Urban
Gerald A. Urban
Jochen KieningerJochen Kieninger
Jochen Kieninger
Electrochemical atomic layer deposition (E-ALD) of copper on polycrystalline gold is a promising method to achieve highly reproducible nanofilms. Cu films of more than 30 nm were deposited by the repetitive execution of underpotential deposition (UPD) of lead and a subsequent surface limited redox replacement by Cu. Both steps were carried out in the same solution. The method enables, in contrast to conventional gas phase ALD, the deposition of layers with different height on the same substrate. Deposit growth in this one-pot system was monitored in-situ with an electrochemical quartz crystal microbalance. Film thickness, measured by optical profilometry, was compared to the number of deposition cycles and indicated a highly linear dependency. Obtained layers were characterized by means of atomic force and scanning electron microscopy and showed a slight roughening with almost no increase in the effective surface area. Energy dispersive X-ray measurements confirmed the purity of deposited Cu nanofilms. It was shown, that even with a simple setup, the described method allows the reproducible deposition of Cu on polycrystalline Au.