Gerald Anton Urban

Gerald Anton Urban

Auto-generated profile, based on publicly available information

Gerald Anton Urban

Laboratory for Sensors, IMTEK—Department of Microsystems Engineering, University of Freiburg, Georges-Köhler Allee 103, D-79110 Freiburg, Germany

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2014 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
AWAndreas Weltin
Andreas Weltin
Jochen KieningerJochen Kieninger
Jochen Kieninger
BEBarbara Enderle
Barbara Enderle
AGAnne-Kathrin Gellner
Anne-Kathrin Gellner
BFBrita Fritsch
Brita Fritsch
GUGerald A. Urban
Gerald A. Urban

2 March 2016 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
AWAndreas Weltin
Andreas Weltin
Jochen KieningerJochen Kieninger
Jochen Kieninger
GUGerald A. Urban
Gerald A. Urban

Abstract

Miniaturized electrochemical in vivo biosensors allow the measurement of fast extracellular dynamics of neurotransmitter and energy metabolism directly in the tissue. Enzyme-based amperometric biosensing is characterized by high specificity and precision as well as high spatial and temporal resolution. Aside from glucose monitoring, many systems have been introduced mainly for application in the central nervous system in animal models. We compare the microsensor principle with other methods applied in biomedical research to show advantages and drawbacks. Electrochemical sensor systems are easily miniaturized and fabricated by microtechnology processes. We review different microfabrication approaches for in vivo sensor platforms, ranging from simple modified wires and fibres to fully microfabricated systems on silicon, ceramic or polymer substrates. The various immobilization methods for the enzyme such as chemical cross-linking and entrapment in polymer membranes are discussed. The resulting sensor performance is compared in detail. We also examine different concepts to reject interfering substances by additional membranes, aspects of instrumentation and biocompatibility. Practical considerations are elaborated, and conclusions for future developments are presented.

ᅟ


8 March 2016 in Journal of Materials Chemistry A
Verified
Journal Article
Open access
PDF file
NTN. B. Tanvir
N. B. Tanvir
OYOlena Yurchenko
Olena Yurchenko
CWCh. Wilbertz
Ch. Wilbertz
GUG. Urban
G. Urban
CO2 sensing at room temperature: the interaction of CO2 and H2O with copper oxide nanoparticles results in reversible formation of basic carbonates. This phenomenon is the key reaction for the work function readout based CO2 sensing which enables the prospects towards low power and low cost gas sensors.

18 October 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SPSusann Podszun
Susann Podszun
PVPaul Vulto
Paul Vulto
HHHelene Heinz
Helene Heinz
SHSydney Hakenberg
Sydney Hakenberg
CHCarsten Hermann
Carsten Hermann
GUGerald A. Urban
Gerald A. Urban
Macro- to micro-volume concentration of viable bacteria is performed in a microfluidic chip. The enrichment principle is based on free flow electrophoresis and is demonstrated for Gram positive bacteria. Bacteria from a suspension flow are trapped on a gel interface that separates the trapping location from integrated actuation electrodes in order to enable non-destructive trapping. The microfluidic chip contains integrated electrolytic gas expulsion structures and phaseguides for gel and liquid handling. Trapping efficiency is systematically optimized to reach 25 times the initial concentration from a theoretical maximum of 30. Finally, enrichment from analytically relevant concentrations down to 3 × 102 colony forming units per millilitre is demonstrated with a trapping efficiency of 80% which represents the most important parameter in enrichment.

4 January 2020 in Polymers
Verified
Journal Article
Open access
PDF file
FWFelicia Wieland
Felicia Wieland
RBRichard Bruch
Richard Bruch
MBMichael Bergmann
Michael Bergmann
SPStefan Partel
Stefan Partel
GUGerald A. Urban
Gerald A. Urban
Can DincerCan Dincer
Can Dincer
Over the last years, polymers have gained great attention as substrate material, because of the possibility to produce low-cost sensors in a high-throughput manner or for rapid prototyping and the wide variety of polymeric materials available with different features (like transparency, flexibility, stretchability, etc.). For almost all biosensing applications, the interaction between biomolecules (for example, antibodies, proteins or enzymes) and the employed substrate surface is highly important. In order to realize an effective biomolecule immobilization on polymers, different surface activation techniques, including chemical and physical methods, exist. Among them, plasma treatment offers an easy, fast and effective activation of the surfaces by micro/nanotexturing and generating functional groups (including carboxylic acids, amines, esters, aldehydes or hydroxyl groups). Hence, here we present a systematic and comprehensive plasma activation study of various polymeric surfaces by optimizing different parameters, including power, time, substrate temperature and gas composition. Thereby, the highest immobilization efficiency along with a homogenous biomolecule distribution is achieved with a 5-min plasma treatment under a gas composition of 50% oxygen and nitrogen, at a power of 1000 W and a substrate temperature of 80 °C. These results are also confirmed by different surface characterization methods, including SEM, XPS and contact angle measurements.

10 October 2022 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JDJohannes Dornhof
Johannes Dornhof
VZViktoria Zieger
Viktoria Zieger
Jochen KieningerJochen Kieninger
Jochen Kieninger
DFDaniel Frejek
Daniel Frejek
RZRoland Zengerle
Roland Zengerle
AWAndreas Weltin
Andreas Weltin
Three-dimensional (3D) cell agglomerates, such as microtissues, organoids, and spheroids, become increasingly relevant in biomedicine. They can provide in vitro models that recapitulate functions of the original tissue in the body and have applications in cancer research. For example, they are widely used in organ-on-chip systems. Microsensors can provide essential real-time information on cell metabolism as well as the reliability and quality of culture conditions. The combination of sensors and 3D cell cultures, especially single spheroids, is challenging in terms of reproducible formation, manipulation, and access to spheroids, precise positioning near sensors, and high cell-to-volume ratios to obtain meaningful biosignals in the most parallel approach possible. To overcome this challenge, we combined state-of-the-art bioprinting techniques to automatically print tumour spheroids directly into microwells of a chip-based electrochemical oxygen sensor array. We demonstrated highly accurate and reproducible spheroid formation (diameter of approx. 200 μm) and a spheroid deposition precision of 25 μm within a volume of 22 nl per droplet. Microstructures and hydrogel-coated microwells allowed the placement of single MCF-7 breast cancer spheroids close to the sensor electrodes. The microelectrode wells were sealed for oxygen measurements within a 55 nl volume for fast concentration changes. Accurate and stable amperometric oxygen sensor performance was demonstrated from atmospheric to anoxic regions. Cellular respiration rates from single tumour spheroids in the range of 450–850 fmol min−1 were determined, and alterations of cell metabolism upon drug exposure were shown. Our results uniquely combine bioprinting with 3D cell culture monitoring and demonstrate the much-needed effort for facilitation, parallelization, sensor integration, and drug delivery in 3D cell culture and organ-on-chip experiments. The workflow has a high degree of automation and potential for scalability. In order to achieve greater flexibility in the automation of spheroid formation and trapping, we employed a method based on drop-on-demand liquid handling systems, instead of the typical on-chip approach commonly used in microfluidics. Its relevance ranges from fundamental metabolic research over standardization of cell culture experiments and toxicological studies, to personalized medicine, e.g. patient-specific chemotherapy.