The need of dc-dc switching converters for power supplies with high-voltage gains has increased in the recent years due to new applications in areas as renewable energy systems, transportation, industrial, medical, and others. A quadratic boost converter is a useful topology to obtain a step-up output voltage; however, a major drawback is the presence of a higher voltage stress over the active and passive switches. In this paper, a quadratic boost converter is combined with a voltage multiplier cell and an output filter to offer a high-voltage gain converter with nonpulsating input and output currents. The expressions for the capacitor voltages and inductor currents are given, as well as the corresponding ripples that allow the proper design of the converter. The bilinear switched, nonlinear averaged and linear averaged models are derived such that the dynamical behavior of the converter is analyzed and used to design a control strategy. A step-by-step procedure is given to tune up a current-mode controller. Experimental results are shown from a prototype, which delivers an output voltage of 220 V and an output power of 300 W. Step load changes between 20% and full load are applied to exhibit the robustness of switching regulator.
23 January 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
This work proposes an output voltage regulation scheme for a fuel-cell based power source. The proposed methodology relies on the design of a dynamic backstepping average current mode controller considering the combined fuel-cell stack and boost converter model. Also, an external loop for voltage regulation using a proportional-integral (PI) action is added. Moreover, to improve the robustness of the current loop, a load estimator using immersion-invariance (I&I) approach is designed. As a result, an adaptive backstepping controller ensuring asymptotic stability via a Lyapunov function is achieved. Finally, based on a 460 W testbench and a DSPACE platform, the closed-loop system performance is evaluated through experimental results. An appropriate output voltage regulation and robust behavior concerning to load variation and fuel-cell stack unregulated DC output voltage are exhibited.
A typical fuel‐cell stack produces a low DC voltage with wide variations; therefore a DC–DC switching converter is required to step up and regulate the output voltage. In this work, a model based on electrical variables is developed for a fuel‐cell stack. This model is later combined with the model of a high step‐up voltage converter to obtain a combined model that incorporates the behaviour of fuel‐cell stack. The resulting model is then used to design an average‐current mode controller for a switching regulator. To test the proposed regulator, a power module with polymer electrolyte membrane fuel cells is used as an input source. This module delivers an output voltage between 26 and 42 V depending on the current being drawn. Experimental results exhibit the robustness of the switching regulator to step changes in the output load and the output voltage of the fuel‐cell stack.
1 November 2006 in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
In this paper, a controller design methodology is given for a cascaded boost converter with a single switch using current-mode control. Nonlinear and linear models are presented, the later exhibits fourth-order characteristic dynamics with right-half side zeros. The proposed control scheme is based on sensing the current of the switch and using it for feedback purposes. When the current loop is introduced, the fourth-order dynamics of the converter is changed to a dominant first-order, which simplifies substantially the controller design of the outer loop. For this loop, a conventional controller is designed. The design-oriented analytic results allow the designer to easily pinpoint the control circuit parameters that optimize the converter's performance. At the end, experimental results are given for a 23 W current-mode regulator
This study discusses a control strategy applied to the switched‐inductor single‐ended primary‐inductance converter (SEPIC) converter suitable for applications where the voltage delivered by a DC source varies from above or below the nominal value. The SEPIC converter can provide a non‐isolated positive output voltage for the above applications; moreover, it exhibits better characteristics when combined with a switched‐inductor cell. A design‐oriented procedure is given that appropriately selects the elements of the converter for a given output voltage and power delivery requirements. A control scheme with two loops is chosen. A high‐gain compensator is used in the inner loop such that the average inductor current follows a current reference. A proportional integral (PI) controller is used in the outer loop for output voltage regulation. The controller was designed using loop‐shaping techniques and applied to regulate an output voltage of 21 V. The design was verified with experimental results in a switching regulator where step changes were applied to the load. The performance of the switching regulator was also tested for variations of the input voltage.
In this paper, a high step-up boost converter with a non-isolated configuration is proposed. This configuration has a quadratic voltage gain, suitable for processing energy from alternative sources. It consists of two boost converters, including a transfer capacitor connected in a non-series power transfer structure between input and output. High power efficiencies are achieved with this arrangement. Additionally, the converter has a common ground and non-pulsating input current. Design conditions and power efficiency analysis are developed. Bilinear and linear models are derived for control purposes. Experimental verification with a laboratory prototype of 500 W is provided. The proposed configuration and similar quadratic configurations are compared experimentally using the same number of components to demonstrate the power efficiency improvement. The resulting power efficiency of the prototype was above 95% at nominal load.